Creatinine Detection by Surface Plasmon Resonance Sensor Using Layers of Cerium Oxide and Graphene Over Conventional Kretschmann Configuration

被引:29
作者
Almawgani, Abdulkarem H. M. [1 ]
Uniyal, Arun [2 ]
Sarkar, Partha [3 ]
Srivastava, Gaurav [4 ]
Alzahrani, Ahmad [1 ]
Taya, Sofyan A. [5 ]
Muduli, Arjuna [6 ]
Pal, Amrindra [7 ,8 ]
机构
[1] Najran Univ, Coll Engn, Elect Dept, Najran, Saudi Arabia
[2] Inst Technol Gopeshwar, Dept Elect & Commun Engn, Chamoli 246424, Uttarakhand, India
[3] Natl Inst Technol, Dept Elect & Commun Engn, Mahatma Gandhi Rd, Durgapur 713209, West Bengal, India
[4] Univ Allahabad, Dept Elect & Commun, Prayagraj 211002, Uttar Pradesh, India
[5] Islamic Univ Gaza, Phys Dept, POB 108, Gaza, Palestine
[6] Koneru Lakshmaiah Educ Fdn, Dept Elect & Commun Engn, Vaddeswaram 522302, Andhra Pradesh, India
[7] DIT Univ, Sch Engn & Technol, Dept ECE, Dehra Dun 248009, Uttarakhand, India
[8] Natl Res Fdn Nepal, Kathmandu 44600, Nepal
关键词
Creatinine detection; Kretschmann configuration; Cerium oxide; Graphene; Refractive in sensor; URINE; NANOPARTICLES; OPTIMIZATION; BLOOD;
D O I
10.1007/s11468-023-01891-0
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
In this study, creatinine in solutions at varied concentrations (non-enzymatic samples) is detected utilizing a surface plasmon resonance (SPR) sensor design. The presence of creatininase enzymes in the creatinine solutions (enzymatic samples) was used to evaluate the sensor's performance. An optical wavelength of 633 nm was used in the angular interrogation technique. The proposed SPR sensor detects the presence of creatinine in blood samples ranging from 10 to 200 mM. The goal of researching the enzymatic sample was to improve the sensor's sensitivity to creatinine in the samples. The non-enzymatic creatinine sample had a sensitivity of 18.42 Degree/RIU, and for creatinine-creatininase, the enhanced sensitivity of 250 Degree/RIU has been achieved when exposed to 633 nm optical wavelength. The increased sensitivity may be owing to an increase in the refractive index of the analyte sensing layer because of creatinine-creatininase coupling activity.
引用
收藏
页码:1743 / 1752
页数:10
相关论文
共 47 条
  • [1] Design and optimization of a novel surface plasmon resonance biosensor based on Otto configuration
    Akowuah, E. K.
    Gorman, T.
    Haxha, S.
    [J]. OPTICS EXPRESS, 2009, 17 (26): : 23511 - 23521
  • [2] A theoretical analysis of refractive index sensor with improved sensitivity using titanium dioxide, graphene, and antimonene grating: Pseudomonas bacteria detection
    Aliqab, Khaled
    Uniyal, Arun
    Srivastava, Gaurav
    Muduli, Arjuna
    Alsharari, Meshari
    Armghan, Ammar
    [J]. MEASUREMENT, 2023, 216
  • [3] Titanium Disilicide, Black Phosphorus-Based Surface Plasmon Resonance Sensor for Dengue Detection
    Almawgani, Abdulkarem H. M.
    Sarkar, Partha
    Pal, Amrindra
    Srivastava, Gaurav
    Uniyal, Arun
    Alhawari, Adam R. H.
    Muduli, Arjuna
    [J]. PLASMONICS, 2023, 18 (04) : 1223 - 1232
  • [4] Detection of hemoglobin concentration in human blood samples using a zinc oxide nanowire and graphene layer heterostructure based refractive index biosensor
    Ansari, Gufranullah
    Pal, Amrindra
    Srivastava, Alok K.
    Verma, Gaurav
    [J]. OPTICS AND LASER TECHNOLOGY, 2023, 164
  • [5] The role of biosensors in coronavirus disease-2019 outbreak
    Asif, Muhammad
    Ajmal, Muhammad
    Ashraf, Ghazala
    Muhammad, Nadeem
    Aziz, Ayesha
    Iftikhar, Tayyaba
    Wang, Junlei
    Liu, Hongfang
    [J]. CURRENT OPINION IN ELECTROCHEMISTRY, 2020, 23 : 174 - 184
  • [6] Surface Plasmon Resonance for Biomarker Detection: Advances in Non-invasive Cancer Diagnosis
    Bellassai, Noemi
    D'Agata, Roberta
    Jungbluth, Vanessa
    Spoto, Giuseppe
    [J]. FRONTIERS IN CHEMISTRY, 2019, 7
  • [7] Cerium Dioxide Thin Films Using Spin Coating
    Channei, D.
    Nakaruk, A.
    Phanichphant, S.
    Koshy, P.
    Sorrell, C. C.
    [J]. JOURNAL OF CHEMISTRY, 2013, 2013
  • [8] Detection V, 2002, RECENT PROGR PLASMON
  • [9] Improvement of Cathode Performance on Pt-CeOx by Optimization of Electrochemical Pretreatment Condition for PEFC Application
    Fugane, Keisuke
    Mori, Toshiyuki
    Ou, Ding Rong
    Yan, Pengfei
    Ye, Fei
    Yoshikawa, Hideki
    Drennan, John
    [J]. LANGMUIR, 2012, 28 (48) : 16692 - 16700
  • [10] Quantitative determination of taurine and related biomarkers in urine by liquid chromatography-tandem mass spectrometry
    Gamagedara, Sanjeewa
    Shi, Honglan
    Ma, Yinfa
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2012, 402 (02) : 763 - 770