Bidirectional Synchronous H6 Inverter for Hybrid AC/DC Distribution System With Improved Light Load Efficiency

被引:0
作者
Alshammari, Meshari [1 ,2 ,3 ]
Duffy, Maeve [1 ,2 ]
机构
[1] Univ Galway, Power Elect Res Ctr, Sch Engn, Galway H91 HX31, Ireland
[2] Univ Galway, Ryan Inst, Galway H91 HX31, Ireland
[3] Jouf Univ, Fac Engn, Elect Engn Dept, Sakaka 72388, Saudi Arabia
关键词
Inverters; Bidirectional control; Standards; Transformers; Leakage currents; Inductors; Rectifiers; DC machines; Synchronous machines; Bidirectional inverter; DC system integration; grid interference; synchronous H6; light-load efficiency; DC DISTRIBUTION; TOPOLOGIES; CHARGER;
D O I
10.1109/ACCESS.2023.3243131
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
The overall efficiency of DC distribution systems may be impacted by the operation of the bidirectional inverter connected to the grid; one of its most critical components. When compared to high-demand industries, the typical load profile of such system in residential buildings is highly variable, including several periods of light-load. Therefore, this paper presents a method to overcome the reduced efficiency at light-load of bidirectional inverters integrated into a DC distribution system powered by renewable energy. Existing topologies are evaluated for obtaining optimal efficiency as well as an investigation of loss breakdown at light-load using analytic models and PSIM simulation. A novel synchronous H6 transformer-less topology is proposed. Simulation results show that the proposed topology can achieve an efficiency of 96.5% under full load and 98.3% under light-load. Efficiency improvements over a standard H6 topology are 4.5% under light-load and 1.5 % at full load. This is mostly due to reduced conduction and switching ON loss of MOSFETs used to replace diodes. When using the rectifier mode, similar levels of improvement are observed, with a 4% increase under light-load and a 1.2% improvement under full load conditions, respectively. Experimental results confirm the effectiveness of the proposed topology, showing nearly the same trend in improvement vs. the standard H6.
引用
收藏
页码:13138 / 13151
页数:14
相关论文
共 39 条
  • [1] Alshammari M., 2019, INT EXH C POW EL INT, P7
  • [2] Review of Single-Phase Bidirectional Inverter Topologies for Renewable Energy Systems with DC Distribution
    Alshammari, Meshari
    Duffy, Maeve
    [J]. ENERGIES, 2022, 15 (18)
  • [3] Feasibility Analysis of a DC Distribution System for a 6 kW Photovoltaic Installation in Ireland
    Alshammari, Meshari
    Duffy, Maeve
    [J]. ENERGIES, 2021, 14 (19)
  • [4] A novel synchronous H6 for improving light load efficiency of bidirectional inverters in a DC distribution system
    Alshammari, Meshari
    Duffy, Maeve
    [J]. 2021 THIRTY-SIXTH ANNUAL IEEE APPLIED POWER ELECTRONICS CONFERENCE AND EXPOSITION (APEC 2021), 2021, : 1666 - 1673
  • [5] [Anonymous], 2016, CALC POW LOSS SYNCHR, P1
  • [6] [Anonymous], 2021, GAT DRIV VOLT REC WO, P3
  • [7] Carneiro B. H., 2017, CALCULATING INTERPRE
  • [8] A Bidirectional High-Efficiency Transformerless Converter With Common-Mode Decoupling for the Interconnection of AC and DC Grids
    Chen, Fang
    Burgos, Rolando
    Boroyevich, Dushan
    [J]. IEEE TRANSACTIONS ON POWER ELECTRONICS, 2019, 34 (02) : 1317 - 1333
  • [9] Chen F, 2017, IEEE ENER CONV, P4128, DOI 10.1109/ECCE.2017.8096717
  • [10] Low-Frequency Common-Mode Voltage Control for Systems Interconnected With Power Converters
    Chen, Fang
    Burgos, Rolando
    Boroyevich, Dushan
    Zhang, Xuning
    [J]. IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2017, 64 (01) : 873 - 882