Study and experimental investigation of insertion force modeling and tissue deformation phenomenon during surgical needle-soft tissue interaction

被引:2
作者
Barua, Ranjit [1 ,6 ]
Das, Surajit [2 ]
Datta, Sudipto [3 ]
Datta, Pallab [4 ]
Chowdhury, Amit Roy [5 ]
机构
[1] IIEST Shibpur, Ctr Healthcare Sci & Technol, Howrah, West Bengal, India
[2] RG Kar Med Coll & Hosp, Kolkata, West Bengal, India
[3] Indian Inst Technol, Roorkee, Uttaranchal, India
[4] Natl Inst Pharmaceut Educ & Res, Kolkata, West Bengal, India
[5] IIEST Shibpur, Aerosp Engn & Appl Mech, Howrah, West Bengal, India
[6] IIEST Shibpur, Ctr Healthcare Sci & Technol, Near be Garden, Howrah 711103, West Bengal, India
关键词
Needle insertion; bevel tip; insertion force; tissue deformation; MIS; frictional stress; DEFLECTION; SIMULATION;
D O I
10.1177/09544062221126628
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Surgical needle insertion is generally used in the current advanced surgery process, particularly in the area of biopsy, MIS or minimally invasive surgery, brachytherapy, etc. During the needle insertion performance into the soft tissue, one of the most important issues is the tissue deformation that affects the needle engagement inside the tissue material. We have presented an energy-based insertion model, and the conical shape of deformed tissue is assumed. The tests are performed on PVA gel samples, and the model is analyzed to determine the tissue deformation volume during needle insertion into soft tissue. The procedures for evaluating the puncture force which creates the deformation of the contact point. With the help of the needle insertion experimental investigation, a geometric model of tissue deformation phenomenon and insertion force was investigated. The active needle-soft tissue contacts are studied, and with the help of the energy-based insertion model, the different factors like strain energy, potential, and dissipated energies are investigated. The tests are completed on the tissue mimic PVA gel samples, and the results show the volume and area of tissue deformation; at the time of initial needle insertion, the maximum tissue deformation arises and during the needle movement in the post-perforation stage, the deformation gradually decreases as the more peripheral work is altered into the vicious and degenerate energies. The maximum insertion force was noticed in 14 degrees bevel angle needle tip and at 3 mm/s needle insertion speed, the volume of tissue deformation was maximum. The maximum deformation of the issue arises at the initial perforate position, and the distortion reduces along with the raises of the needle movement during the post-insertion period as the needle insertion work is converted into vicious and dissolute energies.
引用
收藏
页码:1007 / 1014
页数:8
相关论文
共 27 条
[21]   A comparative study of physics engines for modeling soft tissue deformation [J].
Silva, Daniele F. ;
Maciel, Anderson .
2012 XXXVIII CONFERENCIA LATINOAMERICANA EN INFORMATICA (CLEI), 2012,
[22]   Effect of Skin Thickness on Target Motion during Needle Insertion into Soft-Tissue Phantoms [J].
Abayazid, Momen ;
op den Buijs, Jorn ;
de Korte, Chris L. ;
Misra, Sarthak .
2012 4TH IEEE RAS & EMBS INTERNATIONAL CONFERENCE ON BIOMEDICAL ROBOTICS AND BIOMECHATRONICS (BIOROB), 2012, :755-760
[23]   Simulation and experimental investigation of the surgical needle deflection model during the rotational and steady insertion process [J].
Barua, Ranjit ;
Das, Surajit ;
RoyChowdhury, Amit ;
Datta, Pallab .
INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2023, 46 (01) :40-51
[24]   Modeling and Experimental Studies on Vibration-Induced Force Reduction During Needle Insertion of Thin Tissues [J].
Zhao, Xiaolu ;
Wang, Fujun ;
Tao, Changping ;
Liu, Haitao ;
Liang, Cunman ;
Shi, Beichao .
JOURNAL OF MEDICAL DEVICES-TRANSACTIONS OF THE ASME, 2025, 19 (02)
[25]   Needle-tissue interaction modeling using ultrasound-based motion estimation: Phantom study [J].
Dehghan, Ehsan ;
Wen, Xu ;
Zahiri-Azar, Reza ;
Marchal, Maud ;
Salcudean, Septimiu E. .
COMPUTER AIDED SURGERY, 2008, 13 (05) :265-280
[26]   Experimental Data-Driven Insertion Force Analyses of Hypodermic Needles in a Soft Tissue with an In-House Test Bench [J].
Chavez Pereda, Erick D. ;
Loaiza Duque, Julian D. ;
Ceron Hurtado, Maria A. ;
Gonzalez Rojas, Hernan A. ;
Sanchez Egea, Antonio J. .
APPLIED COMPUTER SCIENCES IN ENGINEERING, WEA 2022, 2022, 1685 :415-422
[27]   A combination of experimental and finite element analyses of needle-tissue interaction to compute the stresses and deformations during injection at different angles [J].
Halabian, Mahdi ;
Beigzadeh, Borhan ;
Karimi, Alireza ;
Shirazi, Hadi Asgharzadeh ;
Shaali, Mohammad Hasan .
JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2016, 30 (06) :965-975