Study and experimental investigation of insertion force modeling and tissue deformation phenomenon during surgical needle-soft tissue interaction

被引:1
作者
Barua, Ranjit [1 ,6 ]
Das, Surajit [2 ]
Datta, Sudipto [3 ]
Datta, Pallab [4 ]
Chowdhury, Amit Roy [5 ]
机构
[1] IIEST Shibpur, Ctr Healthcare Sci & Technol, Howrah, West Bengal, India
[2] RG Kar Med Coll & Hosp, Kolkata, West Bengal, India
[3] Indian Inst Technol, Roorkee, Uttaranchal, India
[4] Natl Inst Pharmaceut Educ & Res, Kolkata, West Bengal, India
[5] IIEST Shibpur, Aerosp Engn & Appl Mech, Howrah, West Bengal, India
[6] IIEST Shibpur, Ctr Healthcare Sci & Technol, Near be Garden, Howrah 711103, West Bengal, India
关键词
Needle insertion; bevel tip; insertion force; tissue deformation; MIS; frictional stress; DEFLECTION; SIMULATION;
D O I
10.1177/09544062221126628
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Surgical needle insertion is generally used in the current advanced surgery process, particularly in the area of biopsy, MIS or minimally invasive surgery, brachytherapy, etc. During the needle insertion performance into the soft tissue, one of the most important issues is the tissue deformation that affects the needle engagement inside the tissue material. We have presented an energy-based insertion model, and the conical shape of deformed tissue is assumed. The tests are performed on PVA gel samples, and the model is analyzed to determine the tissue deformation volume during needle insertion into soft tissue. The procedures for evaluating the puncture force which creates the deformation of the contact point. With the help of the needle insertion experimental investigation, a geometric model of tissue deformation phenomenon and insertion force was investigated. The active needle-soft tissue contacts are studied, and with the help of the energy-based insertion model, the different factors like strain energy, potential, and dissipated energies are investigated. The tests are completed on the tissue mimic PVA gel samples, and the results show the volume and area of tissue deformation; at the time of initial needle insertion, the maximum tissue deformation arises and during the needle movement in the post-perforation stage, the deformation gradually decreases as the more peripheral work is altered into the vicious and degenerate energies. The maximum insertion force was noticed in 14 degrees bevel angle needle tip and at 3 mm/s needle insertion speed, the volume of tissue deformation was maximum. The maximum deformation of the issue arises at the initial perforate position, and the distortion reduces along with the raises of the needle movement during the post-insertion period as the needle insertion work is converted into vicious and dissolute energies.
引用
收藏
页码:1007 / 1014
页数:8
相关论文
共 27 条
  • [11] MECHANICS-BASED BEVEL-TIP NEEDLE DEFLECTION MODEL DURING NEEDLE-SOFT TISSUE INTERACTION PROCESS
    Jiang, Shan
    Wang, Xingji
    Su, Zhiliang
    JOURNAL OF MECHANICS IN MEDICINE AND BIOLOGY, 2014, 14 (05)
  • [12] Soft Tissue Deformation Modeling in the Procedure of Needle Insertion: A Kriging-Based Method
    Yong Lei
    Murong Li
    Dedong Gao
    Chinese Journal of Mechanical Engineering, 2022, 35
  • [13] Force modeling for needle insertion into soft tissue based on mechanical properties and geometric parameters
    宿志亮
    Jiang Shan
    Wang Xingji
    Yan Yu
    High Technology Letters, 2014, 20 (03) : 295 - 300
  • [14] Experimental and simulation investigation of surgical needle insertion into soft tissue mimic biomaterial for minimally invasive surgery (MIS)
    Barua, Ranjit
    Das, Surajit
    Chowdhury, Amit Roy
    Datta, Pallab
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2023, 237 (02) : 254 - 264
  • [15] Development of Veress Needle Insertion Robotic System and Its Experimental Study for Force Acquisition in Soft Tissue
    Nillahoot, Nantida
    Suthakorn, Jackrit
    2013 IEEE INTERNATIONAL CONFERENCE ON ROBOTICS AND BIOMIMETICS (ROBIO), 2013, : 645 - 650
  • [16] Tissue Deformation and Insertion Force of Bee-Stinger Inspired Surgical Needles
    Sahlabadi, Mohammad
    Hutapea, Parsaoran
    JOURNAL OF MEDICAL DEVICES-TRANSACTIONS OF THE ASME, 2018, 12 (03):
  • [17] Needle Force Insertion Modeling based on Comparison of Ex-Vivo Tissue and Phantom Tissue
    Salehuddin, Muhammad
    Suprijanto
    Widyotriatmo, Augie
    PROCEEDINGS OF 2017 INTERNATIONAL CONFERENCE ON SMART CITIES, AUTOMATION & INTELLIGENT COMPUTING SYSTEMS (ICON-SONICS 2017), 2017, : 147 - 150
  • [18] A method for predicting needle insertion deflection in soft tissue based on cutting force identification
    Jiang, Shan
    Gao, Yihan
    Yang, Zhiyong
    Li, Yuhua
    Zhou, Zeyang
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2024,
  • [19] Modeling and Simulation of Flexible Needle Insertion Into Soft Tissue Using Modified Local Constraints
    Gao, Dedong
    Lei, Yong
    Lian, Bin
    Yao, Bin
    JOURNAL OF MANUFACTURING SCIENCE AND ENGINEERING-TRANSACTIONS OF THE ASME, 2016, 138 (12):
  • [20] Force Modeling of Tool-Tissue Interaction Force During Suturing
    Gao, Shuai
    Ji, Shijun
    Feng, Mei
    Li, Qiumeng
    Lu, Xiuquan
    Ni, Zhixue
    Li, Yan
    INTELLIGENT ROBOTICS AND APPLICATIONS, ICIRA 2019, PART VI, 2019, 11745 : 297 - 309