Water absorption and long-term thermal and mechanical properties of carbon/glass hybrid rod for bridge cable

被引:73
作者
Guo, Rui
Li, Chenggao
Xian, Guijun
机构
[1] Harbin Inst Technol, Key Lab Struct Dynam Behav & Control, Minist Educ, Harbin 150090, Heilongjiang, Peoples R China
[2] Harbin Inst Technol, Minist Ind & Informat Technol, Key Lab Smart Prevent & Mitigat Civil Engn Disast, Harbin 150090, Peoples R China
[3] Harbin Inst Technol, Sch Civil Engn, Harbin 150090, Heilongjiang, Peoples R China
基金
中国国家自然科学基金;
关键词
Hygrothermal resistance; Hybrid rod; Water absorption; Degradation mechanism; Interfacial evaluation; POLYMER COMPOSITES; MOISTURE DIFFUSION; EPOXY-RESIN; TENSILE PROPERTIES; PART II; FIBER; GLASS; DURABILITY; PERFORMANCE; BASALT;
D O I
10.1016/j.engstruct.2022.115176
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Fiber reinforced polymer (FRP) composites rod has been used as cable in long-span bridge structure owing to the light weight, high strength and corrosion resistance. The hygrothermal aging will degrade the service performances of FRP cable significantly. In the present study, the accelerated aging experiment of carbon/glass fiber reinforced hybrid rod is conducted through the immersion in deionized water at 40 degrees C, 60 degrees C and 80 degrees C for 403 days. The water absorption and diffusion behavior, evolution of fiber-matrix interfacial strength and dynamic thermo-mechanical property are investigated experimentally. Furthermore, the microstructure characterization is conducted to reveal the degradation mechanism. The results show that the water absorption and diffusion behavior of hybrid rod conforms to a two-stage model, the resin relaxation and interfacial debonding bring about more diffusion path for water molecules at second stage. The resin plasticization and interfacial debonding are the prominte factors lead to the degradation of interfacial strength and glass transition temperature. Furthermore, it is found that the plasticization effect is reversible with the removal of bonding water after drying, while the interfacial debonding is permanent. The long-term life evaluation shows that interface shear strength of hybrid rod shell has a fast degradation rate and reaches to a stable level of 62 %, which provides the key design parameter for bridge structures.
引用
收藏
页数:17
相关论文
共 50 条
[1]   Experimental study on anchoring of FRP-strengthened concrete beams [J].
Ababneh, Ayman N. ;
Al-Rousan, Rajai Z. ;
Ghaith, Issam M. N. .
STRUCTURES, 2020, 23 :26-33
[2]   Novel self-anchored CFRP cable system: Concept and anchorage behavior [J].
Ai, Pengcheng ;
Feng, Peng ;
Lin, Hongwei ;
Zhu, Pengcheng ;
Ding, Guozhen .
COMPOSITE STRUCTURES, 2021, 263
[3]   Moisture diffusion and hygrothermal aging in bismaleimide matrix carbon fiber composites: part II - woven and hybrid composites [J].
Bao, LR ;
Yee, AF .
COMPOSITES SCIENCE AND TECHNOLOGY, 2002, 62 (16) :2111-2119
[4]   Moisture absorption and hygrothermal aging in a bismaleimide resin [J].
Bao, LR ;
Yee, AF ;
Lee, CYC .
POLYMER, 2001, 42 (17) :7327-7333
[5]   Moisture absorption of unidirectional hybrid composites [J].
Barjasteh, E. ;
Nutt, S. R. .
COMPOSITES PART A-APPLIED SCIENCE AND MANUFACTURING, 2012, 43 (01) :158-164
[6]   Characterization and Comparative Durability Study of Glass/Vinylester, Basalt/Vinylester, and Basalt/Epoxy FRP Bars [J].
Benmokrane, Brahim ;
Elgabbas, Fareed ;
Ahmed, Ehab A. ;
Cousin, Patrice .
JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2015, 19 (06)
[7]   Accelerated aging tests for evaluations of durability performance of FRP reinforcing bars for concrete structures [J].
Chen, Yi ;
Davalos, Julio F. ;
Ray, Indrajit ;
Kim, Hyeong-Yeol .
COMPOSITE STRUCTURES, 2007, 78 (01) :101-111
[8]  
Chin JW, 1999, J APPL POLYM SCI, V71, P483, DOI 10.1002/(SICI)1097-4628(19990118)71:3<483::AID-APP15>3.0.CO
[9]  
2-S
[10]  
Crank J., Mathematics of Diffusion, V2nd