Does stress shielding after radial head arthroplasty affect functional outcomes?

被引:8
作者
Lee, Ho-Jae [1 ]
Kim, Byung-Kook [1 ]
Jung, Suk-Han [1 ]
Lee, Younghun [1 ]
Dan, Jinmyoung [1 ]
机构
[1] CHA Univ, Gumi CHA Med Ctr, Dept Orthopaed Surg, Sch Med, Sinsi Ro 10gil 12, Gumi Si 39314, Kyungsangbuk Do, South Korea
关键词
Radial head fractures; Radial head arthroplasty; Stress shielding; PRESS-FIT; PROSTHESIS REPLACEMENT; INTERNAL-FIXATION; FOLLOW-UP; FRACTURES;
D O I
10.1007/s00590-022-03315-x
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background Various complications related to the prosthesis, such as implant loosening and stress shielding phenomenon, could develop after prosthetic replacement of the radial head. Stress shielding is known to occur around rigidly fixed implants. The purpose of this study was to evaluate the clinical influence and causative factors of the stress shielding phenomenon after radial head arthroplasty (RHA). Methods Clinical records and radiographs of 56 patients with unreconstructable radial head fractures who received radial head replacement between 2009 and 2019 were reviewed. Exclusion criteria were infection, loosening, and follow-up of less than 24 months. After exclusion, 35 patients were enrolled. Patients were divided into two groups: an anatomical press-fit group (Anatomical Radial Head System; Acumed, Hillsboro, OR, USA) and a round bipolar cemented group (RHS; Tornier, Montbonnot Saint-Martin, France). Stress shielding around the prosthesis was assessed in the serial radiological examination. Clinical results were assessed using Mayo elbow performance score (MEPS), Quick Disabilities of the Arm, Shoulder, and Hand (q-DASH) score, range of motion (flexion-extension arc and pronation-supination arc), and visual analog scale score (VAS). Correlations between stress shielding phenomenon and demographic data and functional results were analyzed. Results At an average follow-up of 43.06 (+/- 14.6) months, 14 (40%) out of 35 fixed stems demonstrated stress shielding. Our results showed that the rate of stress shielding was significantly higher in cases with a bilateral ligament injury and in the anatomical press-fit group (p = 0.028 and p = 0.0091, respectively). However, stress shielding around prostheses did not affect the clinical results (p > 0.05). Conclusion The stress shielding phenomenon around radial head prosthesis may vary according to prosthetic design and severity of ligament injuries. Stress shielding does not affect the mid-term outcomes in the treatment of acute fractures of the radial head.
引用
收藏
页码:1591 / 1598
页数:8
相关论文
共 24 条
[1]   Outcomes of bipolar radial head prosthesis to treat complex radial head fractures in 22 patients with a mean follow-up of 50 months [J].
Allavena, C. ;
Delclaux, S. ;
Bonnevialle, N. ;
Rongieres, M. ;
Bonnevialle, P. ;
Mansat, P. .
ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2014, 100 (07) :703-709
[2]   The effect of radial head excision and arthroplasty on elbow kinematics and stability [J].
Beingessner, DM ;
Dunning, CE ;
Gordon, KD ;
Johnson, JA ;
King, GJW .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2004, 86A (08) :1730-1739
[3]   Clinical and radiographic comparisons of two different radial head implant designs [J].
Berschback, John C. ;
Lynch, T. Sean ;
Kalainov, David M. ;
Wysocki, Robert W. ;
Merk, Bradley R. ;
Cohen, Mark S. .
JOURNAL OF SHOULDER AND ELBOW SURGERY, 2013, 22 (08) :1108-1120
[4]   Fractures of the Radial Head [J].
Burkhart, Klaus Josef ;
Wegmann, Kilian ;
Mueller, Lars P. ;
Gohlke, Frank E. .
HAND CLINICS, 2015, 31 (04) :533-+
[5]   Mid- to long-term results after bipolar radial head arthroplasty [J].
Burkhart, Klaus Josef ;
Mattyasovszky, Stefan G. ;
Runkel, Martin ;
Schwarz, Christina ;
Kuechle, Raphael ;
Hessmann, Martin H. ;
Rommens, Pol M. ;
Lars, Mueller P. .
JOURNAL OF SHOULDER AND ELBOW SURGERY, 2010, 19 (07) :965-972
[6]  
Carita E, 2017, Musculoskelet Surg, V101, P197, DOI [10.1007/s12306-017-0492-x, 10.1007/s12306-017-0492-x]
[7]   Stress Shielding Around Radial Head Prostheses [J].
Chanlalit, Cholawish ;
Shukla, Dave R. ;
Fitzsimmons, James S. ;
An, Kai-Nan ;
O'Driscoll, Shawn W. .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2012, 37A (10) :2118-2125
[8]   Complications of radial head prostheses [J].
Delclaux, Stephanie ;
Lebon, Julie ;
Faraud, Amelie ;
Toulemonde, Julien ;
Bonnevialle, Nicolas ;
Coulet, Bertrand ;
Mansat, Pierre .
INTERNATIONAL ORTHOPAEDICS, 2015, 39 (05) :907-913
[9]   Prosthesis replacement in Mason III radial head fractures: A meta-analysis [J].
Dou, Q. ;
Yin, Z. ;
Sun, L. ;
Feng, X. .
ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2015, 101 (06) :729-734
[10]   Clinical consequences of stress shielding after porous-coated total hip arthroplasty [J].
Engh, CA ;
Young, AM ;
Engh, CA ;
Hopper, RH .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2003, (417) :157-163