Steady-State Voltage Modelling of a HT-PEMFC under Various Operating Conditions

被引:3
|
作者
Rigal, Sylvain [1 ,2 ]
Jaafar, Amine [2 ]
Turpin, Christophe [2 ]
Horde, Theophile [3 ]
Jollys, Jean-Baptiste [4 ]
Kreczanik, Paul [1 ]
机构
[1] Inst Technol St Exupery IRT St Exupery, 3 Rue Tarfaya, F-31400 Toulouse, France
[2] UPS Univ Paul Sabatier, Univ Toulouse, INPT Inst Natl Polytech Toulouse, LAPLACE Lab Plasma & Convers Energie,CNRS, F-31077 Toulouse, France
[3] Airbus, F-31703 Blagnac, France
[4] Alstom, 50 Rue Dr Guinier, F-65600 Semea, France
关键词
fuel cells; high temperature proton exchange membrane (HT-PEMFC); hydrogen; mathematical model; steady-state model; PROTON-EXCHANGE MEMBRANE; OXYGEN REDUCTION REACTION; FUEL-CELL SYSTEMS; PERFORMANCE DEGRADATION; NEURAL-NETWORK; OPTIMIZATION; CROSSOVER;
D O I
10.3390/en17030573
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
In this work, a commercially available membrane electrode assembly from Advent Technology Inc., developed for use in high-temperature proton exchange membrane fuel cells, was tested under various operating conditions (OCs) according to a sensibility study with three OCs varying on three levels: hydrogen gas over-stoichiometry (1.05, 1.2, 1.35), air gas over-stoichiometry (1.5, 2, 2.5), and temperature (140 degrees C, 160 degrees C, 180 degrees C). A polarization curve (V-I curve) was performed for each set of operating conditions (27 V-I curves in total). A semi-empirical and macroscopic (0D) model of the cell voltage was developed in steady-state conditions to model these experimental data. With the proposed parameterization approach, only one set of parameters is used in order to model all the experimental curves (simultaneous optimization with 27 curves). Thus, an air over-stoichiometry-dependent model was developed. The obtained results are promising between 0.2 and 0.8 A center dot cm-2: an average error less than 1.5% and a maximum error around 7% between modeled and measured voltages with only 9 parameters to identify. The obtained parameters appear consistent, regardless of the OCs. The proposed approach with only one set of parameters seems to be an interesting way to converge towards the uniqueness of consistent parameters.
引用
收藏
页数:18
相关论文
共 50 条
  • [21] Hematopoietic Hierarchy Under Steady-State and Stress Conditions
    Tseng, Yu-Jung
    Chapple, Richard
    Hu, Tianyuan
    Rajapakshe, Kimal
    Hoegenauer, Kevin
    Coarfa, Cristian
    Nakada, Daisuke
    BLOOD, 2019, 134
  • [22] RETENTION OF INFORMATION UNDER CONDITIONS APPROACHING A STEADY-STATE
    SHEPARD, RN
    TEGHTSOONIAN, M
    JOURNAL OF EXPERIMENTAL PSYCHOLOGY, 1961, 62 (03): : 302 - &
  • [23] Experimental investigation of open circuit voltage during start-up process of HT-PEMFC
    Rasheed, Raj Kamal Abdul
    Chan, Siew Hwa
    ELECTROCHIMICA ACTA, 2015, 186 : 353 - 358
  • [24] Characterization of structure of single particles from various automobile engines under steady-state conditions
    Fujitani, Yuji
    Saitoh, Katsumi
    Kondo, Yoshinori
    Fushimi, Akihiro
    Takami, Akinori
    Tanabe, Kiyoshi
    Kobayashi, Shinji
    AEROSOL SCIENCE AND TECHNOLOGY, 2016, 50 (10) : 1055 - 1067
  • [25] Modelling temperature variations and moisture requirements in waste air biofilters under steady-state conditions
    Fazaelipoor, Mohammad Hassan
    ENVIRONMENTAL TECHNOLOGY, 2012, 33 (05) : 507 - 513
  • [26] Steady-state operating conditions of very long EHVAC cable lines
    Gatta, F. M.
    Geri, A.
    Lauria, S.
    Maccioni, M.
    ELECTRIC POWER SYSTEMS RESEARCH, 2011, 81 (07) : 1525 - 1533
  • [27] Experimental investigation and modelling of continuous fluidized bed drying under steady-state and dynamic conditions
    Burgschweiger, J
    Tsotsas, E
    CHEMICAL ENGINEERING SCIENCE, 2002, 57 (24) : 5021 - 5038
  • [28] A direct analytical predetermination of PMSG based WPS steady-state values under different operating conditions
    Vijayapriya, Ramachandran
    Raja, Pitchaimuthu
    Selvan, Manickavasagam Parvathy
    WIND ENGINEERING, 2022, 46 (05) : 1570 - 1589
  • [29] Experimental study on steady-state operation of organic Rankine cycle system under different operating conditions
    Sun, Jian
    Peng, Bin
    SCIENTIFIC REPORTS, 2025, 15 (01):
  • [30] PERFORMANCE OF A HIGH TEMPERATURE PROTON EXCHANGE MEMBRANE FUEL CELL (HT-PEMFC) OPERATING ON SIMULATED REFORMATE
    Waller, Michael G.
    Walluk, Mark R.
    Trabold, Thomas A.
    PROCEEDINGS OF THE ASME 13TH FUEL CELL SCIENCE, ENGINEERING, AND TECHNOLOGY CONFERENCE, 2015, 2016,