Predictive direct power control with phase-locked loop technique of three-level neutral point clamped inverter based shunt active power filter for power quality improvement

被引:8
|
作者
Debdouche, Naamane [1 ]
Benbouhenni, Habib [2 ]
Deffaf, Brahim [3 ]
Anwar, Guessabi [4 ]
Zarour, Laid [1 ]
机构
[1] Bros Mentouri Univ, Dept Elect Engn, Lab Elect Constantine LEC, Constantine 25000, Algeria
[2] Nisantasi Univ, Fac Engn & Architecture, Dept Elect & Elect Engn, Istanbul, Turkiye
[3] Univ Bejaia, Fac Technol, Dept Elect Engn, Lab Renewable Energies Mastering, Bejaia 06000, Algeria
[4] Ferhat Abbas Univ Setif1, Dept Elect Engn, Lab Automat Setif LAS, Setif, Algeria
关键词
phase-locked loop; predictive direct power control; space vector modulation; three-level shunt active power filter; SPACE-VECTOR MODULATION; FED INDUCTION GENERATOR; SAPF; DFIG; PWM; ELIMINATION; HARMONICS; ALGORITHM; STRATEGY; VOLTAGES;
D O I
10.1002/cta.3871
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In this study, an improved anti-windup proportional-integral predictive direct power control strategy with a phase-locked loop (PLL) is proposed and applied to a three-level shunt active power filter (SAPF) neutral point clamped (NPC) inverter using space vector modulation (SVM) technique. The SAPF has to ensure sinusoidal waveforms and unity power factor in the grid side, by eliminating harmonic currents and compensating reactive power of the nonlinear loads. Active and reactive powers as well as the DC bus voltage controls are performed using anti-windup proportional and integral actions with a predictive algorithm, without a need for an exhaustive mathematical model. The control law is modulated using the SVM technique allowing fixed switching frequency and low power ripples. The performances of the suggested control have been verified through an electronic STM32F407 card under diverse and severe conditions. The obtained results confirmed the expected objectives in terms of current and voltage quality, robustness, and dynamic response. Direct power control approach featuring Phase-Locked Loop (PLL), which is implemented in a three-level Shunt Active Power Filter (SAPF) neutral point clamped (NPC) inverter utilizing space vector modulation (SVM) technique. The SAPF's objective is to guarantee grid-side sinusoidal waveforms and unity power factor, while mitigating harmonic currents, compensating reactive power, reducing Total Harmonic Distortion (THD) in the current, enhancing the longevity of the filtration system, and refining the system's dynamic response.image
引用
收藏
页码:3306 / 3340
页数:35
相关论文
共 50 条
  • [41] A Novel Phase Current Reconstruction Method for a Three-Level Neutral Point Clamped Inverter (NPCI) with a Neutral Shunt Resistor
    Son, Yungdeug
    Kim, Jangmok
    ENERGIES, 2018, 11 (10)
  • [42] ANN based controller for three phase four leg shunt active filter for power quality improvement
    Jayachandran, J.
    Sachithanandam, R. Murali
    AIN SHAMS ENGINEERING JOURNAL, 2016, 7 (01) : 275 - 292
  • [43] Performance Improvement of Shunt Active power filter with Combined Control Technique
    Puhan, Pratap Sekhar
    Ray, Pravat Kumar
    Panda, Gayadhar
    2017 INTERNATIONAL CONFERENCE ON EMERGING TRENDS & INNOVATION IN ICT (ICEI), 2017, : 56 - 61
  • [44] Direct Power Control Switching Table Concept and Analysis for Three-phase Shunt Active Power Filter
    Chaoui, A.
    Gaubert, J-P.
    Bouafia, A.
    JOURNAL OF ELECTRICAL SYSTEMS, 2013, 9 (01) : 52 - 65
  • [45] Power Quality Improvement Based on Shunt Active Power Filter Connected to a Photovoltaic Array
    Belaidi, Rachid
    Fathi, Mohamed
    Larafi, Mohamed Mghezzi
    Kaci, Gunia Mohand
    Belaidi, Rachid
    Haddouche, A.
    PROCEEDINGS OF 2015 3RD IEEE INTERNATIONAL RENEWABLE AND SUSTAINABLE ENERGY CONFERENCE (IRSEC'15), 2015, : 557 - 562
  • [46] PSPWM based Five-Level Shunt Active Filter for Power Quality Improvement in Power System Network
    Rani, R. Sheba
    Rao, C. Srinivasa
    Kumar, M. Vijaya
    FIRST INTERNATIONAL CONFERENCE ON POWER ENGINEERING COMPUTING AND CONTROL (PECCON-2017 ), 2017, 117 : 794 - 801
  • [47] Power Quality Improvement Using VF-DPC-SVM Controlled Three-Phase Shunt Active Filter
    Saidi, Salem
    Abbassi, Rabeh
    Chebbi, Souad
    2015 IEEE 12TH INTERNATIONAL MULTI-CONFERENCE ON SYSTEMS, SIGNALS & DEVICES (SSD), 2015,
  • [48] Power Electronic Traction Transformer Based on No Phase-locked Loop Control
    Xie, Jingyan
    Shuai, Zhikang
    Hong, Yi
    Wu, Yuxiang
    2019 22ND INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES AND SYSTEMS (ICEMS 2019), 2019, : 3969 - 3973
  • [49] A Three Phase Shunt Active Power Filter Based on Instantaneous Reactive Power Theory
    Prabhu, Yogesh S.
    Dharme, A. A.
    Talange, D. B.
    2014 ANNUAL IEEE INDIA CONFERENCE (INDICON), 2014,
  • [50] Three-level Inverter based on Direct Power Control connecting offshore wind farm
    Xie Lei
    Xie Da
    Zhang Yanchi
    2009 INTERNATIONAL CONFERENCE ON SUSTAINABLE POWER GENERATION AND SUPPLY, VOLS 1-4, 2009, : 1922 - +