Evaluation of X-ray doses in paediatrics multislice computed tomography

被引:1
|
作者
Khajmi, H. [1 ]
Nouh, F. A. [2 ]
Tounsi, A. [3 ]
Touti, R. [4 ]
机构
[1] Higher Inst Nursing Profess & Hlth Tech, Marrakech, Morocco
[2] Cadi Ayyad Univ Marrakech, Natl Ctr Studies & Res Water & Energy CNEREE, Marrakech, Morocco
[3] Univ Sultan Moulay Sliman, Environm Ecol & Agroind Engn Lab, Beni Mellal, Morocco
[4] Hassan II Univ Casablanca, Fac Sci Ain Chouk, Phys Particles & Med Phys Team, Casablanca, Morocco
关键词
Computed tomography; CTDIvol; DLP; paediatric; DRL; RADIATION ACCIDENTS; MEDICAL PREPAREDNESS; NUCLEAR; EMERGENCY; COMMUNICATION; MANAGEMENT; RECOVERY;
D O I
10.1051/radiopro/2023029
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The present paper aims to examine the doses delivered to children at the paediatric Computer Tomography (CT) unit in the radiology service of the Mother and Child Hospital (MCH) in the Mohammed VI University Hospital Centre (Med VI UHC) of Marrakech, Morocco, and to compare our values with the dosimetric data of the published literature. This investigation included 440 CT examinations of the head, chest, and abdomen-pelvis in paediatric patients whose ages ranged from 1 to 5 yr (AG(1y5y)), 5 to 10 yr (AG(5y10y)), and 10 to 15 yr (AG(10y15y)). We estimated the 75th percentile values of the Volume Computed Tomography Dose Index CTDIvol (mGy) and the Dose-Length-Product DLP (mGy.cm). The obtained results showed that the calculated 75th percentile of DLP for head CT are less than the National Diagnostic Reference Levels (DRLs) observed in Japan, Belgium, Germany, French, United Kingdom, United State, and China. However, the proposed DRLs for the abdomen-pelvis, and chest CT are significantly higher compared with international DRLs.
引用
收藏
页码:303 / 308
页数:6
相关论文
共 50 条
  • [41] Quantitative X-ray phase contrast computed tomography with grating interferometryBiomedical applications of quantitative X-ray grating-based phase contrast computed tomography
    Lorenz Birnbacher
    Eva-Maria Braig
    Daniela Pfeiffer
    Franz Pfeiffer
    Julia Herzen
    European Journal of Nuclear Medicine and Molecular Imaging, 2021, 48 : 4171 - 4188
  • [42] Quasimonochromatic x-ray computed tomography by the balanced filter method using a conventional x-ray source
    Saito, M
    MEDICAL PHYSICS, 2004, 31 (12) : 3436 - 3443
  • [43] Study of Soil Compaction Using X-Ray Computed Tomography
    Al-Hattamleh, O.
    Razavi, M. R.
    Muhunthan, B.
    JORDAN JOURNAL OF CIVIL ENGINEERING, 2008, 2 (02) : 111 - 123
  • [44] Characterization of a spectroscopic detector for application in x-ray computed tomography
    Dooraghi, Alex A.
    Fix, Brian J.
    Smith, Jerel A.
    Brown, William D.
    Azevedo, Stephen G.
    Martz, Harry E.
    DEVELOPMENTS IN X-RAY TOMOGRAPHY XI, 2017, 10391
  • [45] Quantitative evaluation of the effect of changes in effective energy on the image quality in X-ray computed tomography
    Ishiguro, Ayana
    Sato, Kazuhiro
    Taura, Masaaki
    Hoshi, Hideki
    PHYSICAL AND ENGINEERING SCIENCES IN MEDICINE, 2020, 43 (02) : 567 - 575
  • [46] Comparison of 3D X-ray tomography with computed tomography in patients with distal extremity fractures
    Anna L. Falkowski
    Balazs K. Kovacs
    Fides R. Schwartz
    Robyn M. Benz
    Bram Stieltjes
    Anna Hirschmann
    Skeletal Radiology, 2020, 49 : 1965 - 1975
  • [47] Comparison of 3D X-ray tomography with computed tomography in patients with distal extremity fractures
    Falkowski, Anna L.
    Kovacs, Balazs K.
    Schwartz, Fides R.
    Benz, Robyn M.
    Stieltjes, Bram
    Hirschmann, Anna
    SKELETAL RADIOLOGY, 2020, 49 (12) : 1965 - 1975
  • [48] Quantitative evaluation of the effect of changes in effective energy on the image quality in X-ray computed tomography
    Ayana Ishiguro
    Kazuhiro Sato
    Masaaki Taura
    Hideki Hoshi
    Physical and Engineering Sciences in Medicine, 2020, 43 : 567 - 575
  • [49] Comparison of diagnostic value of multidetector computed tomography and X-ray in the detection of body packing
    Bulakci, Mesut
    Kalelioglu, Tuba
    Bulakci, Betul Bozkurt
    Kiris, Adem
    EUROPEAN JOURNAL OF RADIOLOGY, 2013, 82 (08) : 1248 - 1254
  • [50] Precession x-ray ptychography with multislice approach
    Shimomura, Kei
    Suzuki, Akihiro
    Hirose, Makoto
    Takahashi, Yukio
    PHYSICAL REVIEW B, 2015, 91 (21):