Performance of round-ended recycled aggregate CFST stub columns after fire exposure

被引:6
|
作者
Zhao, Hui [1 ,2 ]
Wang, Zhenhe [1 ,2 ]
Zhang, Wenhao [1 ,2 ]
Wang, Rui [1 ,2 ]
Yang, Dongdong [3 ]
Lam, Dennis [4 ]
机构
[1] Taiyuan Univ Technol, Coll Civil Engn, Taiyuan 030024, Peoples R China
[2] Taiyuan Univ Technol, Shanxi Key Lab Civil Engn Disaster Prevent & Contr, Taiyuan 030024, Peoples R China
[3] Yangzhou Univ, Coll Architectural Sci & Engn, Dept Civil Engn, Yangzhou 225127, Peoples R China
[4] Univ Bradford, Fac Engn & Informat, Bradford BD7 1DP, England
关键词
Recycled aggregate concrete; CFST columns; Post-fire; Residual capacity; Round-ended; COARSE RCA CONCRETE; BEHAVIOR; STRENGTH; DESIGN;
D O I
10.1016/j.jcsr.2023.108311
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The post-fire performance of round-ended recycled aggregate concrete-filled steel tubular (RE-RACFST) short columns has been investigated experimentally and numerically. The test parameters included cross-section aspect ratios, recycled aggregate replacements and steel ratios. Twelve short columns were first heated for 90 min following ISO 834 standard fire, followed by natural cooling. Subsequently, axial compressive tests were performed to obtain the damage mode, load versus axial deformation, and strain development of the columns. The test results revealed that a higher level of recycled aggregate content resulted in decreased bearing capacity and elastic stiffness of RE-RACFSTs, and an earlier onset of the confining effect. Furthermore, finite element (FE) models were established and benchmarked against the experimental results. Parametric investigations were then conducted to study the effects of key factors on the residual load-carrying capacity. Finally, according to the experimental and FE results, a simplified formula was proposed to estimate the post-fire residual capacity of RERACFST stub columns.
引用
收藏
页数:16
相关论文
共 50 条
  • [41] Circular rubber aggregate CFST stub columns under axial compression: prediction and reliability analysis
    Megahed, Khaled
    Mahmoud, Nabil Said
    Abd-Rabou, Saad Elden Mostafa
    SCIENTIFIC REPORTS, 2024, 14 (01):
  • [42] Experimental investigation on cyclic behavior of concrete-filled round-ended stainless steel tubular columns
    Shi, Feng-Wei
    Dong, Shuo
    Chen, Hai-Tao
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2025, 228
  • [43] Analysis of the performance of flow field modes around double round-ended piers
    Yan-fen Geng
    Hui Chen
    Hua-qiang Guo
    Meng-ya Guo
    Environmental Fluid Mechanics, 2023, 23 : 161 - 179
  • [44] Flexural performance of round-ended concrete-filled steel tubular specimens
    Guo, Jun-Tao
    Wang, Zhi-Bin
    Tan, Ee Loon
    Gao, Yang-Hong
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2024, 215
  • [45] Post-fire behaviour and resistances of square recycled aggregate concrete-filled stainless steel tube stub columns
    Wang, Ziyi
    Zhong, Yukai
    Jiang, Ke
    Su, Meini
    Zhao, Ou
    THIN-WALLED STRUCTURES, 2024, 197
  • [46] Axial compressive strength of square and rectangular CFST columns using recycled aggregate concrete with low to high recycled aggregate replacement ratios
    Guneyisi, Erhan
    CONSTRUCTION AND BUILDING MATERIALS, 2023, 367
  • [47] Structural Performance of Nanosilica-Blended Square and Circular CFST Stub Columns
    Adak, Dibyendu
    Chand, Abhishek
    Patton, M. Longshithung
    Dutta, Subhrajit
    Bisht, Himanshu
    PRACTICE PERIODICAL ON STRUCTURAL DESIGN AND CONSTRUCTION, 2023, 28 (03)
  • [48] Performance of concrete-encased CFST stub columns under axial compression
    Han, Lin-Hai
    An, Yu-Feng
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2014, 93 : 62 - 76
  • [49] Fire design of steel-reinforced CFST stub columns with high-strength materials
    Medall, David
    Romero, Manuel L.
    Thai, Huu-Tai
    Espinos, Ana
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2024, 218
  • [50] Structural performance of welded built-up square CFST stub columns
    Lee, Seong-Hui
    Choi, Young-Hwan
    Kim, Young-Ho
    Choi, Sung-Mo
    THIN-WALLED STRUCTURES, 2012, 52 : 12 - 20