Strength and Behavior of Glass Fiber-Reinforced Polymer-Reinforced Concrete Box Girders without Web Reinforcement under Pure Torsion

被引:0
|
作者
Mostafa, Ibrahim T. [1 ]
Mousa, Salaheldin [1 ]
Mohamed, Hamdy M. [1 ]
Benmokrane, Brahim [2 ]
机构
[1] Univ Sherbrooke, Dept Civil & Bldg Engn, Sherbrooke, PQ, Canada
[2] Univ Sherbrooke, Dept Civil & Bldg Engn, Tier 1, Sherbrooke, PQ, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
cracking pattern and modes of failure; design codes; glass fiber-reinforced polymer (GFRP) bars; reinforced concrete (RC) box girders; reinforcement ratio; theoretical modeling; torsional crack width and toughness; torsional loading; torsional moment-twist response; torsional strength; BEAMS; BARS;
D O I
10.14359/51738836
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The torsional behavior of solid reinforced concrete (RC) members reinforced with fiber-reinforced polymer (FRP) bars has been the subject of several experimental studies. No experimental research, however, seems to have focused on RC box girders reinforced with FRP bars under a pure torsional moment. This paper reports the results of an experimental investigation on the torsional strength and behavior of full-scale RC box girders reinforced with longitudinal glass FRP (GFRP) bars. All specimens measured 380 mm (15 in.) in height, 380 mm (15 in.) in width, 100 mm (4 in.) wall thickness, and 4000 mm (157.48 in.) in length. They were tested under pure torsional loading over a clear span of 2000 mm (78.74 in.). The test specimens consisted of four RC box girders with longitudinal GFRP bars and one RC box girder with longitudinal steel bars as a reference. All the specimens were constructed without web reinforcement to study the contribution of the longitudinal reinforcement to torsional strength. The test variables included the longitudinal reinforcement ratio (ranging between 1.10 and 2.74%) and the type of longitudinal reinforcement (GFRP or steel). The test results indicate that increasing the GFRP longitudinal reinforcement ratio increased the torsional strength after the initiation of the first diagonal crack, especially for specimens with a high reinforcement ratio. In addition, theoretical torsional moment-twist curves were developed and gave predictions consistent with the experimental test results. Lastly, the ultimate torsional strength of the GFRP-RC box girders without web reinforcement was estimated with the CSA S806-12 (R2017) design equation with a modification related to the GFRP tensile strain limit.
引用
收藏
页码:63 / 76
页数:14
相关论文
共 50 条
  • [1] Behavior and Strength of Glass Fiber-Reinforced Polymer-Reinforced Concrete Deep Beams with Web Openings
    Frappier, Jacob
    Mohamed, Khaled
    Farghaly, Ahmed Sabry
    Benmokrane, Brahim
    ACI STRUCTURAL JOURNAL, 2019, 116 (05) : 275 - 286
  • [2] Influence of Reinforcement Ratio on Seismic Performance of Glass Fiber-Reinforced Polymer-Reinforced Concrete Columns under Torsion
    Selmy, Yasser M.
    El-Salakawy, Ehab F.
    ACI STRUCTURAL JOURNAL, 2024, 121 (06) : 121 - 132
  • [3] Shear Capacity of Glass Fiber-Reinforced Polymer-Reinforced Concrete Continuous Deep Beams without Web Reinforcement
    Mohamed, Ahmed
    Mahmoud, Karam
    El-Salakawy, Ehab F.
    ACI STRUCTURAL JOURNAL, 2021, 118 (03) : 85 - 99
  • [4] Glass Fiber-Reinforced Polymer-Reinforced Concrete Columns with Varied Concrete Strength under Combined Bending-Torsion Cyclic Loading
    Selmy, Yasser M.
    Abdallah, Amr E.
    El-Salakawy, Ehab F.
    ACI STRUCTURAL JOURNAL, 2024, 121 (06) : 133 - 144
  • [5] Effect of Axial Load and Web Reinforcement Ratio on Seismic Behavior of Glass Fiber-Reinforced Polymer-Reinforced Concrete Squat Walls
    Shabana, Islam
    Farghaly, Ahmed Sabry
    Benmokrane, Brahim
    ACI STRUCTURAL JOURNAL, 2021, 118 (04) : 109 - 121
  • [6] Thickness of Glass Fiber-Reinforced Polymer-Reinforced Concrete Slabs
    Hussain, Zahid
    Lin, Jan
    Trussoni, Matthew Jacob
    Nanni, Antonio
    ACI STRUCTURAL JOURNAL, 2023, 120 (03) : 187 - 196
  • [7] Experimental Behavior of Glass Fiber-Reinforced Polymer-Reinforced Concrete Columns under Lateral Cyclic Load
    Elshamandy, Mohammed G.
    Farghaly, Ahmed Sabry
    Benmokrane, Brahim
    ACI STRUCTURAL JOURNAL, 2018, 115 (02) : 337 - 349
  • [8] Experimental Investigation on Pure Torsion Behavior of Concrete Beams Reinforced with Glass Fiber-Reinforced Polymer Bars
    Bai, Haoyang
    Jiang, Jiafei
    Xue, Weichen
    Hu, Xiang
    BUILDINGS, 2024, 14 (09)
  • [9] Novel shear reinforcement for fiber-reinforced polymer-reinforced and prestressed concrete
    Whitehead, PA
    Ibell, TJ
    ACI STRUCTURAL JOURNAL, 2005, 102 (02) : 286 - 294
  • [10] Experiments on Seismic Behavior of Rectangular Glass Fiber-reinforced Polymer-reinforced Concrete Columns
    Deng Z.
    Gao L.
    Wang X.
    Yingyong Jichu yu Gongcheng Kexue Xuebao/Journal of Basic Science and Engineering, 2019, 27 (05): : 1065 - 1076