LC-MS/MS method for the quantitation of decitabine and venetoclax in rat plasma after SPE: Application to pharmacokinetic study

被引:2
|
作者
Alnasser, Abdulaziz I. [1 ]
Hefnawy, Mohamed M. [1 ]
Al-Hossaini, Abdullah M. [1 ]
Bin Jardan, Yousef A. [2 ]
El-Azab, Adel S. [1 ]
Abdel-Aziz, Alaa M. [1 ]
Al-Obaid, Abdulrahman M. [1 ]
Al-Suwaidan, Ibrahim A. [1 ]
Attwa, Mohamed W. [1 ]
El-Gendy, Manal A. [1 ]
机构
[1] King Saud Univ, Coll Pharm, Dept Pharmaceut Chem, Riyadh 11451, Saudi Arabia
[2] King Saud Univ, Coll Pharm, Dept Pharmaceut, Riyadh 11451, Saudi Arabia
关键词
LC-MS/MS; Acute myeloid leukemia; Decitabine; Venetoclax; Rat plasma; Pharmacokinetics; THERAPY; QUANTIFICATION;
D O I
10.1016/j.jsps.2023.06.026
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
This study developed a novel, sensitive and selective LC-MS/MS method for the concurrent determination of DCB and VTX in rat plasma using encorafenib as internal standard (IS). To identify DCB, VTX, and IS, the positive multiple reaction monitoring (MRM) mode was used. Chromatographic separation was carried out using a reversed-phase Agilent Eclipse plus C18 column (100 mm x 2.1 mm, 3.5 lm) and an isocratic mobile phase made up of water with 0.1% formic acid and acetonitrile (50:50, v/v, pH 3.2) at a flow rate of 0.30 mL/min for 3.0 min. Prior to analysis, the DCB and VTX with the IS were extracted from plasma using the solid-phase extraction (SPE) method. High recovery rates for DCB, VTX and IS were achieved using the C18 cartridge without interference from plasma endogenous. The developed method was validated as per the FDA guidelines over a linear concentration range in rat plasma from 5-3000 and 5-1000 ng/mL for DCB and VTX, respectively with r(2) >= 0.998. For both drugs, the lower limits of detection (LLOD) were 2.0 ng/mL. After the HLOQ sample was injected, less than 20% of the LLOQ of DCB, VTX, and less than 5% of the IS carry-over in the blank sample was attained. The overall recoveries of DCB and VTX from rat plasma were in the range of 90.68-97.56%, and the mean RSD of accuracy and precision results was <= 6.84%. For the first time, the newly developed approach was effectively used in a pharmacokinetic study on the simultaneous oral administration of DCB and VTX in rats that received 15.0 mg/kg of DCB and 100.0 mg/kg of VTX. (c) 2023 The Author(s). Published by Elsevier B.V. on behalf of King Saud University. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
引用
收藏
页数:10
相关论文
共 50 条
  • [41] An UPLC-MS/MS Method for the Quantitation of Ledipasvir in Rat Plasma: Application to a Pharmacokinetic Study
    Zhang, Kun
    Ma, Xiang-qin
    Li, Zhi-hao
    Zhang, Yun-long
    Song, Ji-jun
    LATIN AMERICAN JOURNAL OF PHARMACY, 2016, 35 : 1116 - 1121
  • [42] Highly sensitive LC-MS/MS-ESI method for simultaneous quantitation of albendazole and ricobendazole in rat plasma and its application to a rat pharmacokinetic study
    Sharma, Kuldeep
    Kandaswamy, Murugesh
    Mithra, Chandan
    Meena, Ashok Kumar
    Giri, Sanjeev
    Rajagopal, Sriram
    Mullangi, Ramesh
    BIOMEDICAL CHROMATOGRAPHY, 2012, 26 (02) : 247 - 255
  • [43] LC-MS/MS Determination of Apigenin in Rat Plasma and Application to Pharmacokinetic Study
    Zhu, Shixing
    Zhang, Jiayuan
    Lv, Zhihua
    Yu, Mingming
    CURRENT PHARMACEUTICAL BIOTECHNOLOGY, 2021, 22 (02) : 274 - 280
  • [44] Development and validation of a high throughput LC-MS/MS method for simultaneous quantitation of pioglitazone and telmisartan in rat plasma and its application to a pharmacokinetic study
    Sengupta, Pinaki
    Chatterjee, Bappaditya
    Mandal, Uttam Kumar
    Gorain, Bapi
    Pal, Tapan Kumar
    JOURNAL OF PHARMACEUTICAL ANALYSIS, 2017, 7 (06) : 381 - 387
  • [45] Application of LC-MS/MS method for determination of dihydroartemisin in human plasma in a pharmacokinetic study
    Wang, Huanhuan
    Yao, Xueting
    Wang, Teng
    Yan, Shuai
    Jiang, Ji
    Zhang, Fengchun
    Liu, Junfeng
    Gao, Duo
    Ma, Zhanguo
    Zhao, Qian
    Liu, Dongyang
    Hu, Pei
    BIOANALYSIS, 2020, 12 (22) : 1635 - 1646
  • [46] Development and validation of an LC-MS/ MS method for the determination of hinokiflavone in rat plasma and its application to a pharmacokinetic study
    Yin, Ruofeng
    Xiong, Kun
    Wen, Simin
    Wang, Yuanyi
    Xu, Feng
    BIOMEDICAL CHROMATOGRAPHY, 2017, 31 (03)
  • [47] Quantitative analysis of atractylenolide I in rat plasma by LC-MS/MS method and its application to pharmacokinetic study
    Li, Yujuan
    Zhang, Yushi
    Wang, Zhimin
    Zhu, Jingjing
    Tian, Yuan
    Chen, Bo
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2012, 58 : 172 - 176
  • [48] HIGHLY SENSITIVE LC-MS/MS METHOD FOR THE DETERMINATION OF CLOZAPINE IN RAT PLASMA: APPLICATION TO A PRECLINICAL PHARMACOKINETIC STUDY
    Haas, Sandra Elisa
    Brum, Liberato, Jr.
    de Andrade, Cristiane
    Azeredo, Francine Johansson
    Pigatto, Maiara
    Silva Torres, Bruna Gaelzer
    Guterres, Silvia Stanicuaski
    Dalla Costa, Teresa
    JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2012, 35 (20) : 2873 - 2883
  • [49] A simple and sensitive LC-MS/MS method for determination of miltirone in rat plasma and its application to pharmacokinetic studies
    Guo, Long
    Duan, Li
    Dong, Xin
    Dou, Li-Li
    Zhou, Ping
    Liu, E-Hu
    Li, Ping
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2014, 973 : 33 - 38
  • [50] A sensitive LC-MS/MS method to quantify loureirin B in rat plasma with application to preclinical pharmacokinetic studies
    Li, Yujuan
    Li, Yongzhi
    Yang, Zhezhe
    Xin, Nian
    Deng, Yulin
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2009, 50 (05) : 983 - 986