Effects of high-resolution measurements between different multi-row detectors on volumetric modulated arc therapy patient-specific quality assurance

被引:2
作者
Kunii, Y. [1 ]
Tanabe, Y. [2 ]
Higashi, A. [1 ]
Nakamoto, A. [1 ]
Nishioka, K. [1 ]
机构
[1] Tokuyama Cent Hosp, Dept Radiol, 1-1 Kodacho, Yamaguchi, Japan
[2] Okayama Univ, Fac Med, Grad Sch Hlth Sci, Okayama, Japan
来源
INTERNATIONAL JOURNAL OF RADIATION RESEARCH | 2023年 / 21卷 / 03期
关键词
Patient-specific QA; volumetric modulated arc therapy; single measurement; high-resolution measure- ment; radiation treatment planning system; RADIATION-THERAPY; IMRT; VMAT; VERIFICATION; DELIVERY; 2D;
D O I
10.52547/ijrr.21.3.9
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: This study aimed to evaluate the optimal criteria and conditions in which single-measurement (SM) and high-resolution measurement (HM) provide a similar evaluation accuracy for ArcCHECK (AC) and Octavius (OT) detectors. Materials and Methods: In the SM and HM for AC and OT, we evaluated & gamma;-analysis pass-rate differences for various conditions (criteria, calculation grid size, and shift of the isocenter) of 20 patients who received volumetric modulated arc therapy. All results of the & gamma;-analysis pass rate were analyzed using the Anderson-Darling normality test. Results: In the AC detector, an SM with a 1%/1 mm criterion, 1.25 mm calculation grid size, and two standard deviations (2SD) of tolerance showed an evaluation accuracy similar to that of an HM. In the OT detector, an SM with a 2%/2 mm criterion, 2.0 mm calculation grid, and 2SD of tolerance had an evaluation accuracy similar to that of an HM. The & gamma;-pass-rate data of the OT detector for the 3%/3 mm criterion did not follow a normal distribution in both SM and HM. Conclusions: Most high & gamma;-analysis pass rates achieved using inadequate criteria may not detect errors; therefore, accurate evaluation is necessary for optimizing the criteria settings of individual QA devices based on the characteristics and the uncertainties of array detectors. The characteristics of a detector array can be enhanced by evaluating the relationship between SM and HM, which reduces the workload of patient-specific QA.
引用
收藏
页码:413 / 420
页数:8
相关论文
共 41 条
[31]   Treatment plan complexity quantification for predicting gamma passing rates in patient-specific quality assurance for stereotactic volumetric modulated arc therapy [J].
Xue, Xudong ;
Luan, Shunyao ;
Ding, Yi ;
Li, Xiangbin ;
Li, Dan ;
Wang, Jingya ;
Ma, Chi ;
Jiang, Man ;
Wei, Wei ;
Wang, Xiao .
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2024, 25 (09)
[32]   Deep learning for patient-specific quality assurance of volumetric modulated arc therapy: Prediction accuracy and cost-sensitive classification performance [J].
Li, Guangjun ;
Duan, Lian ;
Xie, Lizhang ;
Hu, Ting ;
Wei, Weige ;
Bai, Long ;
Xiao, Qing ;
Liu, Wenjie ;
Zhang, Lei ;
Bai, Sen ;
Yi, Zhang .
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2024, 125
[33]   Development of a deep learning-based error detection system without error dose maps in the patient-specific quality assurance of volumetric modulated arc therapy [J].
Kimura, Yuto ;
Kadoya, Noriyuki ;
Oku, Yohei ;
Jingu, Keiichi .
JOURNAL OF RADIATION RESEARCH, 2023, 64 (04) :728-737
[34]   Comparison of Gafchromic EBT2 and EBT3 for patient-specific quality assurance: Cranial stereotactic radiosurgery using volumetric modulated arc therapy with multiple noncoplanar arcs [J].
Fiandra, Christian ;
Fusella, Marco ;
Giglioli, Francesca Romana ;
Filippi, Andrea Riccardo ;
Mantovani, Cristina ;
Ricardi, Umberto ;
Ragona, Riccardo .
MEDICAL PHYSICS, 2013, 40 (08)
[35]   From 2D to 3D gamma passing rate tolerance and action limits for patient-specific quality assurance in volumetric-modulated arc therapy [J].
Zarros, Christos ;
Patatoukas, George ;
Kollaros, Nikos ;
Chalkia, Marina ;
Kougioumtzopoulou, Andromachi ;
Kouloulias, Vasilios ;
Platoni, Kalliopi .
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2025,
[36]   Setting the Tolerance and Action Limit for Patient-specific Quality Assurance of Craniospinal Irradiation Volumetric Modulated Arc Therapy: Based on AAPM TG-218 Report [J].
Raj, Sathiya ;
Saminathan, Sathiyan ;
Prakasam, Kiruthika .
JOURNAL OF MEDICAL PHYSICS, 2025, 50 (01) :155-159
[37]   Implementing and evaluating a high-resolution diode array for patient-specific quality assurance of robotic brain stereotactic radiosurgery/radiotherapy [J].
Xu, Qianyi ;
Huynh, Kiet ;
Nie, Wei ;
Rose, Mark S. ;
Chawla, Ashish K. ;
Choe, Kevin S. ;
Kanani, Samir ;
Kubicek, Gregory J. ;
Fan, Jiajin .
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2022, 23 (05)
[38]   Effect of Multileaf Collimator Leaf Position Error Determined by Picket Fence Test on Gamma Index Value in Patient-Specific Quality Assurance of Volumetric-Modulated Arc Therapy Plans [J].
Ceylan, Cemile ;
Inal, Serpil Yondem ;
Senol, Elif ;
Yilmaz, Berrin ;
Sahin, Sevim .
CUREUS JOURNAL OF MEDICAL SCIENCE, 2021, 13 (01)
[39]   Patient-specific quality control for intensity-modulated radiation therapy and volumetric-modulated arc therapy using electronic portal imaging device and two-dimensional ion chamber array [J].
Kausar, Abu ;
Mani, Karthick R. ;
Azhari, Hasin A. ;
Zakaria, Golam A. .
JOURNAL OF RADIOTHERAPY IN PRACTICE, 2019, 18 (01) :26-31
[40]   Efficient dose-volume histogram-based pretreatment patient-specific quality assurance methodology with combined deep learning and machine learning models for volumetric modulated arc radiotherapy [J].
Gong, Changfei ;
Zhu, Kecheng ;
Lin, Chengyin ;
Han, Ce ;
Lu, Zhongjie ;
Chen, Yuanhua ;
Yu, Changhui ;
Hou, Liqiao ;
Zhou, Yongqiang ;
Yi, Jinling ;
Ai, Yao ;
Xiang, Xiaojun ;
Xie, Congying ;
Jin, Xiance .
MEDICAL PHYSICS, 2022, 49 (12) :7779-7790