Development of the high energy engineering X-ray (HEX) superconducting wiggler, magnetic measurement, installation, and commissioning

被引:2
作者
Tanabe, T. [1 ]
Corwin, T. [1 ]
Hidas, D. [1 ]
Musardo, M. [1 ]
Migliorino, D. [1 ]
Rank, J. [1 ]
Seegitz, M. [1 ]
Todd, R. [1 ]
Hidaka, Y. [1 ]
Hobl, A. [2 ]
Grau, A. [3 ]
机构
[1] Brookhaven Natl Lab Upton, Upton, NY 11973 USA
[2] Bilfinger Noell GmbH, Alfred Nobel Str 20, D-97080 Wurzburg, Germany
[3] Karlsruhe Inst Technol KIT, Inst Beam Phys & Technol IBPT, Kaiserstr 12, D-76131 Karlsruhe, Germany
关键词
Compilation and indexing terms; Copyright 2025 Elsevier Inc;
D O I
10.1063/5.0146964
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The High energy Engineering X-ray (HEX) diffraction beamline at the National Synchrotron Light Source II (NSLS-II) at Brookhaven National Lab (BNL) is the first high-energy beamline capable of reaching 200 keV for a monochromatic beam. With the 3 GeV electron beam energy for the NSLS-II ring, only the superconducting wiggler (SCW) producing greater than 4 T peak field can cover these ranges with a sufficient number of photons. The 1.2 m-long HEX-SCW has a period length of 70 mm and a field strength on-axis of 4.3 T. It utilizes no liquid helium, and the vertical aperture size of the electron beam vacuum chamber is 8 mm. Unlike regular undulators/wigglers, there is no standard configuration for the magnetic measurement system for superconducting insertion devices. The NSLS-II Insertion Devices group has developed, in collaboration with the vacuum group, a novel in-vacuum Hall mapper with a 1.75 m in-vacuum linear motor and an in-vacuum flip coil system utilizing many commercial-off-the-shelf products. The measurements were conducted at the BNL, and the device was installed in the ring and commissioned. This paper provides a description of the SCW and its magnetic measurement systems, as well as a brief account of the installation and commissioning efforts.
引用
收藏
页数:10
相关论文
共 16 条
  • [1] Abliz M., 2011, P 2011 PART ACC C NE
  • [2] [Anonymous], NSLS 2 PRELIMINARY D
  • [3] A practical fit for the critical surface of NbTi
    Bottura, L
    [J]. IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2000, 10 (01) : 1054 - 1057
  • [4] Characterization of 30-cm-Long Superconducting Undulator Coils With the Magnetic Measurement System CASPER II
    Grau, A.
    Casalbuoni, S.
    Gerstl, S.
    Glamann, N.
    Holubek, T.
    de Jauregui, D. Saez
    Voutta, R.
    Boffo, C.
    Gerhard, T.
    Turenne, M.
    Walter, W.
    [J]. IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2016, 26 (04)
  • [5] Hidaka Y., 2019, P 2019 PART ACC C ME
  • [6] Jain A. K., 1997, P CERN ACCELERATOR S
  • [7] Jiang Y, 2021, ASIA COMMUN PHOTON
  • [8] Kitegi C. A., 2012, P IPAC2012 NEW ORL L
  • [9] Musardo M., 2015, P 6 INT PART ACC C I, P1693
  • [10] Musardo M., 2013, P PAC2013 PAS CA