Shade match comparison of CAD-CAM single crowns to a lithium disilicate crown

被引:1
作者
Li, Rui [1 ]
Lin, Yu-Chun [2 ]
Sadid-Zadeh, Ramtin [1 ,3 ]
机构
[1] Univ Buffalo, Dept Restorat Dent, Sch Dent Med, Buffalo, NY USA
[2] Augusta Univ, Dept Restorat Sci, Dent Coll Georgia, Augusta, GA USA
[3] Univ Buffalo, Dept Restorat Dent, Sch Dent Med, 222 Squire Hall, Buffalo, NY 14214 USA
来源
JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY | 2024年 / 33卷 / 03期
关键词
all-ceramic crown; shade assessment; shade match; spectrophotometer; IN-VITRO; ZIRCONIA; COLOR; TRANSLUCENCY; RESTORATIONS; THICKNESS; STRENGTH;
D O I
10.1111/jopr.13676
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
PurposeTo assess the shade match ability of four varieties of all-ceramic crowns to a neighboring bilayered lithium disilicate crown. Material and methodsA dentiform was used to fabricate a bilayered lithium disilicate crown on the maxillary right central incisor, following the anatomy and shade of a selected natural tooth. Two crowns (one full-contour, one cutback) were then designed on a prepared maxillary left central incisor, following the contour of the neighboring crown. The designed crowns were used to manufacture monolithic lithium disilicate, bilayered lithium disilicate, bilayered zirconia, and monolithic zirconia crowns, 10 each. An intraoral scanner and a spectrophotometer were used to assess the frequency of matched shades and to calculate the color difference (Delta E) between the two central incisors at the incisal, middle, and cervical thirds. Kruskal-Wallis and two-way ANOVA were used to compare the frequency of matched shades and Delta E values, respectively (alpha = 0.05). ResultsThere was no significant (p > 0.05) difference in frequencies of matched shades for each group at the three sites; except bilayered lithium disilicate crowns. Bilayered lithium disilicate crowns had significantly (p < 0.05) higher match frequency than monolithic zirconia at the middle third. The Delta E value was not significantly (p > 0.05) different among the groups at the cervical third. However, monolithic zirconia had significantly (p < 0.05) higher Delta E values than bilayered lithium disilicate and zirconia at the incisal and middle thirds. ConclusionsBilayered lithium disilicate and zirconia appeared to most closely match the shade of an existing bilayered lithium disilicate crown.
引用
收藏
页码:246 / 251
页数:6
相关论文
共 50 条
  • [1] Fit and fatigue behavior of CAD-CAM lithium disilicate crowns
    Alves, William Garcia
    Souza, Luiza Freitas Brum
    Pereira, Gabriel Kalil Rocha
    Valandro, Luiz Felipe
    Kapczinski, Myriam Pereira
    Mengatto, Cristiane Machado
    Fraga, Sara
    JOURNAL OF PROSTHETIC DENTISTRY, 2023, 130 (02) : 241.e1 - 241.e8
  • [2] Clinical evaluation of the fit of lithium disilicate crowns fabricated with three different CAD-CAM systems
    Ahn, Jong-Ju
    Bae, Eun-Bin
    Lee, Jin-Ju
    Choi, Jae-Won
    Jeon, Young-Chan
    Jeong, Chang-Mo
    Yun, Mi-Jung
    Lee, So-Hyoun
    Lee, Kyu-Bok
    Huh, Jung-Bo
    JOURNAL OF PROSTHETIC DENTISTRY, 2022, 127 (02) : 239 - 247
  • [3] CAD-CAM and heat-press: Comparison of internal and marginal fit of lithium disilicate copings
    Bella, Marcia
    Lins, Leonardo
    Canabarro, Antonio
    MICROSCOPY RESEARCH AND TECHNIQUE, 2024, 87 (09) : 2186 - 2193
  • [4] Evaluation of marginal and internal fit of lithium disilicate CAD-CAM crowns with different finish lines by using a micro-CT technique
    Rizonaki, Maria
    Jacquet, Wolfgang
    Bottenberg, Peter
    Depla, Lennert
    Boone, Matthieu
    De Coster, Peter J.
    JOURNAL OF PROSTHETIC DENTISTRY, 2022, 127 (06) : 890 - 898
  • [5] RESEARCH AND EDUCATION Comparing the color match of monolithic CAD-CAM dental ceramics with the VITA Classical shade guide
    Shirani, Mohammadjavad
    Emami, Maryam
    Mosharraf, Ramin
    Savabi, Omid
    Akhavankhaleghi, Mehrdad
    Azadbakht, Kamran
    JOURNAL OF PROSTHETIC DENTISTRY, 2024, 132 (03) : 605 - 611
  • [6] The marginal fit of lithium disilicate crowns: Press vs. CAD/CAM
    Azar, Basel
    Eckert, Steve
    Kunkela, Josef
    Ingr, Tomas
    Mounajjed, Radek
    BRAZILIAN ORAL RESEARCH, 2018, 32
  • [7] Marginal adaptation of CAD/CAM milled lithium disilicate glass ceramic crowns
    Kojima, K.
    Nagaoka, K.
    Murata, Y.
    Yamamoto, K.
    Akiyama, S.
    Hokii, Y.
    Fusejima, F.
    JOURNAL OF OSSEOINTEGRATION, 2022, 14 (04) : 201 - 204
  • [8] Fracture analysis of monolithic CAD-CAM crowns
    Kashkari, Afnan
    Yilmaz, Burak
    Brantley, William A.
    Schricker, Scott R.
    Johnston, William M.
    JOURNAL OF ESTHETIC AND RESTORATIVE DENTISTRY, 2019, 31 (04) : 346 - 352
  • [9] Effect of sintering on the translucency of CAD-CAM lithium disilicate restorations: A comparative in vitro study
    Jurado, Carlos A.
    Afrashtehfar, Kelvin I.
    Hyer, Jared
    Alhotan, Abdulaziz
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2023, 32 (09): : 861 - 866
  • [10] Comparison of Fracture Resistance for Chairside CAD/CAM Lithium Disilicate Crowns and Overlays with Different Designs
    Jurado, Carlos Alberto
    Kaleinikova, Zinaida
    Tsujimoto, Akimasa
    Trevino, Daniel Alberto Cortes
    Seghi, Robert R.
    Lee, Damian J.
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2022, 31 (04): : 341 - 347