Calculation Method of the Finite Soil Pressure for a New Foundation Pit Adjacent to an Existing Subway Station

被引:3
|
作者
Zhang, Zhenbo [1 ,2 ]
Zhou, Jiadi [3 ,4 ]
Xu, Fei [1 ,2 ]
Liu, Zhichun [3 ,4 ]
Sun, Minglei [3 ,4 ]
机构
[1] Shijiazhuang Tiedao Univ, Key Lab Large Struct Hlth Monitoring & Control, Shijiazhuang 050043, Peoples R China
[2] Shijiazhuang Tiedao Univ, Sch Safety Engn & Emergency Management, Shijiazhuang 050043, Peoples R China
[3] Shijiazhuang Tiedao Univ, State Key Lab Mech Behav & Syst Safety Traff Engn, Shijiazhuang 050043, Peoples R China
[4] Shijiazhuang Tiedao Univ, Sch Civil Engn, Shijiazhuang 050043, Peoples R China
来源
APPLIED SCIENCES-BASEL | 2023年 / 13卷 / 03期
基金
中国国家自然科学基金;
关键词
underground engineering; foundation pit; existing subway station; finite soil; resultant force; calculation method; RIGID RETAINING WALLS; ACTIVE EARTH PRESSURE; BACKFILL; THRUST;
D O I
10.3390/app13031994
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
The study aimed at the simple prediction problem of finite soil pressure for a new foundation pit adjacent to an existing subway station. Failure modes of the finite soil were proposed. Considering the friction between the soil and the structural interface, the formulas for calculating the finite soil pressure were derived with the horizontal differential element method, and the distribution was discussed. Furthermore, a simple calculation method for the resultant force of the finite soil pressure and the height of the action point was proposed with the principle of area equivalence. With the example and model tests, the rationality of the above method was verified. The influences of parameters on the resultant force of the soil pressure and the relative height of the resultant force were analyzed. The main conclusions are as follows: (1) The finite soil pressure has a nonlinear distribution and is lower than the conventional soil pressure. (2) Compared with other existing methods and model test results, the proposed finite soil pressure calculation method and simplified method are rational. (3) The finite soil pressure increases with the ground overload and soil weight and decreases with the internal friction angle and the structure-soil friction angle. (4) The relative height of the resultant force of the finite soil pressure increases with the structure-soil friction angle and decreases with the internal friction angle. (5) The proximity and covering soil thickness of the existing subway station have a lesser influence on the finite soil pressure, whereas the internal friction angle, weight, structure-soil friction angle and ground overload have a greater influence on the finite soil pressure. (6) The structure-soil friction angle has a greater influence on the height of the action point. The height of the resultant force is one-third of the enclosure structure depth if the structure-soil friction angle is 0.
引用
收藏
页数:19
相关论文
共 50 条
  • [41] Monitoring and numerical simulation of deformation of retaining structure in subway station foundation pit
    Liu Jie
    Yao Hai-lin
    Ren Jian-xi
    ROCK AND SOIL MECHANICS, 2010, 31 : 456 - 461
  • [42] An Integrated Intelligent Approach for Monitoring and Management of a Deep Foundation Pit in a Subway Station
    Hong, Chengyu
    Zhang, Jinyang
    Chen, Weibin
    SENSORS, 2022, 22 (22)
  • [43] Study on reinforcement method for foundation pit of existing shield tunnel under foundation pit
    Shi, Chenghua
    Li, Xiang
    Lei, Mingfeng
    Peng, Limin
    Journal of Railway Science and Engineering, 2020, 17 (05) : 1147 - 1155
  • [44] A method for calculating active earth pressure of soil piece with a finite width between adjacent foundation pits
    Yue Shu-qiao
    Zuo Ren-yu
    Lu Zhao
    ROCK AND SOIL MECHANICS, 2016, 37 (07) : 2063 - 2069
  • [45] Deformation of deep and large foundation pit in soft soil of Fuzhou Subway
    Yang, Jianhui
    Kong, Deyi
    ARABIAN JOURNAL OF GEOSCIENCES, 2020, 13 (01)
  • [46] Deformation of deep and large foundation pit in soft soil of Fuzhou Subway
    Jianhui Yang
    Deyi Kong
    Arabian Journal of Geosciences, 2020, 13
  • [47] Deformation Stability Response of Adjacent Subway Tunnels considering Excavation and Support of Foundation Pit
    Liu, Baohua
    Lin, Hang
    Chen, Yifan
    Liu, Jingshuo
    Guo, Chun
    LITHOSPHERE, 2022, 2022 (SpecialIssue10)
  • [48] Deformation Effects of Deep Foundation Pit Excavation on Retaining Structures and Adjacent Subway Stations
    Jiang, Zhijian
    Zhu, Shu
    Que, Xiangcheng
    Ge, Xinliang
    BUILDINGS, 2024, 14 (08)
  • [49] Instability mode of limited soil in adjacent foundation pit engineering
    Zhang, Zhen-bo
    Li, Bing-xin
    Yang, Qian
    Liu, Zhi-chun
    Liu, Yi
    ROCK AND SOIL MECHANICS, 2025, 46 (01) : 266 - 277
  • [50] Analysis of deformation characteristics of foundation pit of metro station and adjacent buildings induced by deep excavation in soft soil
    Liu Nian-wu
    Chen Yi-tian
    Gong Xiao-nan
    Yu Ji-tao
    ROCK AND SOIL MECHANICS, 2019, 40 (04) : 1515 - +