Calculation Method of the Finite Soil Pressure for a New Foundation Pit Adjacent to an Existing Subway Station

被引:3
|
作者
Zhang, Zhenbo [1 ,2 ]
Zhou, Jiadi [3 ,4 ]
Xu, Fei [1 ,2 ]
Liu, Zhichun [3 ,4 ]
Sun, Minglei [3 ,4 ]
机构
[1] Shijiazhuang Tiedao Univ, Key Lab Large Struct Hlth Monitoring & Control, Shijiazhuang 050043, Peoples R China
[2] Shijiazhuang Tiedao Univ, Sch Safety Engn & Emergency Management, Shijiazhuang 050043, Peoples R China
[3] Shijiazhuang Tiedao Univ, State Key Lab Mech Behav & Syst Safety Traff Engn, Shijiazhuang 050043, Peoples R China
[4] Shijiazhuang Tiedao Univ, Sch Civil Engn, Shijiazhuang 050043, Peoples R China
来源
APPLIED SCIENCES-BASEL | 2023年 / 13卷 / 03期
基金
中国国家自然科学基金;
关键词
underground engineering; foundation pit; existing subway station; finite soil; resultant force; calculation method; RIGID RETAINING WALLS; ACTIVE EARTH PRESSURE; BACKFILL; THRUST;
D O I
10.3390/app13031994
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
The study aimed at the simple prediction problem of finite soil pressure for a new foundation pit adjacent to an existing subway station. Failure modes of the finite soil were proposed. Considering the friction between the soil and the structural interface, the formulas for calculating the finite soil pressure were derived with the horizontal differential element method, and the distribution was discussed. Furthermore, a simple calculation method for the resultant force of the finite soil pressure and the height of the action point was proposed with the principle of area equivalence. With the example and model tests, the rationality of the above method was verified. The influences of parameters on the resultant force of the soil pressure and the relative height of the resultant force were analyzed. The main conclusions are as follows: (1) The finite soil pressure has a nonlinear distribution and is lower than the conventional soil pressure. (2) Compared with other existing methods and model test results, the proposed finite soil pressure calculation method and simplified method are rational. (3) The finite soil pressure increases with the ground overload and soil weight and decreases with the internal friction angle and the structure-soil friction angle. (4) The relative height of the resultant force of the finite soil pressure increases with the structure-soil friction angle and decreases with the internal friction angle. (5) The proximity and covering soil thickness of the existing subway station have a lesser influence on the finite soil pressure, whereas the internal friction angle, weight, structure-soil friction angle and ground overload have a greater influence on the finite soil pressure. (6) The structure-soil friction angle has a greater influence on the height of the action point. The height of the resultant force is one-third of the enclosure structure depth if the structure-soil friction angle is 0.
引用
收藏
页数:19
相关论文
共 50 条
  • [21] Interactions of Foundation Pit on the Underlying Adjacent Existing Underground Structures
    Xu, Wanzhong
    Liu, Baohua
    Liu, Jingshuo
    Guo, Chun
    GEOFLUIDS, 2022, 2022
  • [22] Interactions of Foundation Pit on the Underlying Adjacent Existing Underground Structures
    Xu, Wanzhong
    Liu, Baohua
    Liu, Jingshuo
    Guo, Chun
    GEOFLUIDS, 2022, 2022
  • [23] Effect Analysis on Foundation Pit Excavation Adjacent to Existing Railway
    Yang Yi
    Zhou Jun
    CONSTRUCTION AND URBAN PLANNING, PTS 1-4, 2013, 671-674 : 209 - +
  • [24] Analysis and information construction of foundation pit for Shipaiqiao subway station in Guangzhou
    An Guan-feng
    Gao Jun-yue
    ROCK AND SOIL MECHANICS, 2005, 26 (11) : 1837 - +
  • [25] Monitoring and numerical simulation of deep foundation pit of a subway station in Lanzhou
    Ye S.-H.
    Ding S.-H.
    Gong X.-N.
    Gao S.
    Chen C.-L.
    Yantu Gongcheng Xuebao/Chinese Journal of Geotechnical Engineering, 2018, 40 : 177 - 182
  • [26] Research on the Deep Foundation Pit and Dewatering Design of Chanhe Subway Station
    Wang, Shenxia
    Journal of Railway Engineering Society, 2020, 37 (08) : 11 - 14
  • [27] Deformation control of a newly-built subway station crossing the adjacent existing subway tunnel
    Chen, Mengqiao
    Yang, Guangwu
    Zhongguo Tiedao Kexue/China Railway Science, 2011, 32 (04): : 53 - 59
  • [28] Mechanism of dewatering-induced ground subsidence in deep subway station pit and calculation method
    Wang, Jianxiu
    Wu, Lingao
    Zhu, Yanfei
    Tang, Yiqun
    Yang, Ping
    Lou, Rongxiang
    Yanshilixue Yu Gongcheng Xuebao/Chinese Journal of Rock Mechanics and Engineering, 2009, 28 (05): : 1010 - 1019
  • [29] Calculation method of additional load of adjacent metro tunnels due to foundation pit excavation
    Wei G.
    Zhao C.
    1600, Academia Sinica (35): : 3408 - 3417
  • [30] An analytic study on the deflection of subway tunnel due to adjacent excavation of foundation pit
    Zelin Zhou
    Shougen Chen
    Peng Tu
    Haisheng Zhang
    Journal of Modern Transportation, 2015, 23 (04) : 287 - 297