Feasibility of concomitant exclusion of left atrial appendage during novel transapical off-pump beating heart mitral valve repair

被引:0
作者
Chan, Daniel Tai-Leung [1 ]
Bhatia, Inderjeet [1 ]
Lam, Simon Chi-Cheung [2 ]
Au, Timmy Wing-Kuk [1 ]
机构
[1] Queen Mary Hosp, Dept Cardiothorac Surg, Room 308, New Clin Bldg, Hong Kong, Peoples R China
[2] Queen Mary Hosp, Dept Med, Div Cardiol, Hong Kong, Peoples R China
关键词
AtriClip; Atrial fibrillation; Minimally invasive cardiac surgery; NeoChord; Mitral valve repair; LIGATION; SURGERY;
D O I
10.1007/s10047-023-01383-2
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The AtriClip device enables the safe and reproducible epicardial clipping of the left atrial appendage. Transapical off-pump beating heart mitral valve repair using NeoChord DS100 Artificial Chordae Delivery System has matured and become more standardized. We aim to evaluate the feasibility of combining NeoChord repair and left atrial appendage exclusion in a single procedure through the same minithoracotomy in patients with mitral valve prolapse and atrial fibrillation. From 2018 to 2019, seven patients with severe mitral regurgitation and atrial fibrillation underwent transesophageal echocardiography-guided transapical off-pump mitral valve repair with the novel NeoChord DS 1000 system and concomitant left atrial appendage exclusion using the AtriClip Pro II device. Both procedures were performed via left mini-thoracotomy. The AtriClip device was applied after the NeoChord repair was done. All seven patients had less than moderate mitral regurgitation after the NeoChord repair and successful left atrial appendage occlusion. There were no device or procedure-related complications. Clinical follow-up revealed significant symptomatic improvement, and no cardiovascular complications were reported. Transesophageal echocardiography at 6-12 months post-procedure showed stable left atrial appendage occlusion with no residual flow between the left atrium and the left atrial appendage and a stump of less than 5 mm. Beating heart epicardial clipping of the left atrial appendage using AtriClip concomitant with transapical mitral valve repair using Neochord DS 1000 system is a feasible and safe treatment option in mitral valve prolapse and atrial fibrillation in patients with limited indications. However, its safety needs to be confirmed in a larger series of patients.
引用
收藏
页码:57 / 64
页数:8
相关论文
共 50 条
  • [1] Feasibility of concomitant exclusion of left atrial appendage during novel transapical off-pump beating heart mitral valve repair
    Daniel Tai-Leung Chan
    Inderjeet Bhatia
    Simon Chi-Cheung Lam
    Timmy Wing-Kuk Au
    Journal of Artificial Organs, 2024, 27 : 57 - 64
  • [2] Feasibility of novel transapical off pump beating heart mitral valve repair in a patient with dextrocardia and situs inversus
    Bhatia, Inderjeet
    Chan, Daniel Tai-Leung
    Lam, Simon Chi-Cheung
    Au, Timmy Wing-Kuk
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2020, 58 (02) : 392 - 394
  • [3] Anesthetic Management of Transapical Off-Pump Mitral Valve Repair With NeoChord Implantation
    Kavakli, Ali Sait
    Ozturk, Nilgun Kavrut
    Ayoglu, Raif Umut
    Emmiler, Mustafa
    Ozyurek, Lutfi
    Inanoglu, Kerem
    Ozmen, Sadik
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2016, 30 (06) : 1587 - 1593
  • [4] A mitral annulus tracking approach for navigation of off-pump beating heart mitral valve repair
    Li, Feng P.
    Rajchl, Martin
    Moore, John
    Peters, Terry M.
    MEDICAL PHYSICS, 2015, 42 (01) : 456 - 468
  • [5] Left atrial appendage exclusion during mitral valve surgery and stroke in atrial fibrillation
    Abrich, Victor A.
    Narichania, Aalap D.
    Love, William T.
    Lanza, Louis A.
    Shen, Win-Kuang
    Sorajja, Dan
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2018, 53 (03) : 285 - 292
  • [6] Artificial papillary muscle device for off-pump transapical mitral valve repair
    Imbrie-Moore, Annabel M.
    Zhu, Yuanjia
    Park, Matthew H.
    Paulsen, Michael J.
    Wang, Hanjay
    Woo, Y. Joseph
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2022, 164 (04) : E133 - E141
  • [7] Transapical off-pump mitral valve repair with NeoChord implantation: A systematic review
    Ahmed, Ahmed
    Abdel-Aziz, Tarek A.
    AlAsaad, Mohannad M. R.
    Majthoob, Motaz
    JOURNAL OF CARDIAC SURGERY, 2021, 36 (04) : 1492 - 1498
  • [8] CT for the Transapical Off-Pump Mitral Valve Repair With Neochord Implantation Procedure
    Colli, Andrea
    Zucchetta, Fabio
    Kliger, Chad
    Bellu, Roberto
    Francone, Marco
    Sedati, Pietro
    Jelnin, Vladimir
    Ruiz, Carlos E.
    Manzan, Erica
    Besola, Laura
    Bizzotto, Eleonora
    Gerosa, Gino
    JACC-CARDIOVASCULAR IMAGING, 2017, 10 (11) : 1397 - 1400
  • [9] Left atrial appendage exclusion during mitral valve surgery and stroke in atrial fibrillation
    Victor A. Abrich
    Aalap D. Narichania
    William T. Love
    Louis A. Lanza
    Win-Kuang Shen
    Dan Sorajja
    Journal of Interventional Cardiac Electrophysiology, 2018, 53 : 285 - 292
  • [10] Review of transapical off-pump mitral valve intervention with NeoChord implantation
    Hassanabad, Ali Fatehi
    Kent, William D. T.