Laparoscopic renal surgery using multi degree-of-freedom articulating laparoscopic instruments in a porcine model

被引:9
|
作者
Kim, Jong Keun [1 ]
Kang, Bosik [2 ]
Kim, Yu Seon [3 ]
Yun, Yujin [4 ]
Jang, Myoung Jin [5 ]
Bae, Donghwan [6 ]
You, Dalsan [3 ,7 ]
机构
[1] Hallym Univ, Dongtan Sacred Heart Hosp, Dept Urol, Hwaseong, South Korea
[2] Univ Ulsan, Asan Med Ctr, Coll Med, Dept Urol, Seoul, South Korea
[3] Univ Ulsan, Asan Med Inst Convergence Sci & Technol, Asan Med Ctr,Coll Med, Dept Urol, Seoul, South Korea
[4] Asan Med Ctr, Robot Surg Ctr, Seoul, South Korea
[5] Asan Med Ctr, Asan Inst Life Sci, Seoul, South Korea
[6] LIVSMED, Seongnam, South Korea
[7] Univ Ulsan, Asan Med Ctr, Coll Med, Dept Urol,Asan Med Inst Convergence Sci & Technol, 88 Olymp-Ro 43-Gil, Seoul 05505, South Korea
关键词
Joints; Kidney; Laparoscopy; Robotics; NEPHRECTOMY; OUTCOMES; ASSOCIATION; UROLOGY; REPAIR;
D O I
10.4111/icu.20220182
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Purpose: We evaluated the performance of a new multi-degree-of-freedom articulating laparoscopic instrument, ArtiSential, and compared it with that of a straight-shaped instrument and the da Vinci surgical system, in renal surgery using porcine model. Materials and Methods: Nine female Yorkshire pigs were equally divided into three groups. The three groups were compared at each surgical step in terms of objective and subjective parameters. Results: The median operative times for renal pedicle clamping and ureter dissection were significantly shorter in ArtiSential group than robotic group (1.3 min vs. 4.7 min, p=0.002; 8.1 min vs. 11.1 min, p=0.015). The median operative time for bladder repair was significantly longer in ArtiSential group than robotic and straight-shaped groups (17.9 min vs. 5.5 min, p=0.002; 17.9 min vs. 9.3 min, p=0.026). There were no significant differences among groups in terms of blood loss or intraoperative complications. ArtiSential device was less useable for renorrhaphy (p=0.009) and bladder repair (p=0.002) compared to the robotic system. ArtiSential group was less accurate than robotic group in terms of tumor resection, renorrhaphy, and bladder repair. During ureter dissection, bladder cuff excision, and bladder repair, the surgeon experienced greater wrist discomfort but lesser back discomfort in ArtiSential group than robotic group. Conclusions: For most steps, ArtiSential performed as well as robotic and straight-shaped instruments. The development of specialized surgical techniques for ArtiSential will maximize the advantages of these instruments.
引用
收藏
页码:91 / 101
页数:11
相关论文
共 50 条
  • [1] Evaluation of new motorized articulating laparoscopic instruments by laparoscopic novices using a standardized laparoscopic skills curriculum
    Uysal, Daniel
    Gasch, Claudia
    Behnisch, Rouven
    Nickel, Felix
    Mueller-Stich, Beat Peter
    Hohenfellner, Markus
    Teber, Dogu
    SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2021, 35 (02): : 979 - 988
  • [2] Evaluation of new motorized articulating laparoscopic instruments by laparoscopic novices using a standardized laparoscopic skills curriculum
    Daniel Uysal
    Claudia Gasch
    Rouven Behnisch
    Felix Nickel
    Beat Peter Müller-Stich
    Markus Hohenfellner
    Dogu Teber
    Surgical Endoscopy, 2021, 35 : 979 - 988
  • [3] Renal ischemia time in laparoscopic surgery: an experimental study in a porcine model
    Humphreys, Mitchell R.
    Castle, Erik P.
    Lohse, Christine M.
    Sebo, Thomas J.
    Leslie, Kevin O.
    Andrews, Paul E.
    INTERNATIONAL JOURNAL OF UROLOGY, 2009, 16 (01) : 105 - 109
  • [4] Renal tolerance to prolonged warm ischemia time in a laparoscopic versus open surgery porcine model
    Laven, BA
    Orvieto, MA
    Chuang, MS
    Ritch, CR
    Murray, P
    Harland, RC
    Inman, SR
    Brendler, CB
    Shalhav, AL
    JOURNAL OF UROLOGY, 2004, 172 (06) : 2471 - 2474
  • [5] High Intensity Focused Ultrasound Renal Tissue Ablation: A Laparoscopic Porcine Model
    Orvieto, Marcelo A.
    Zorn, Kevin C.
    Lyon, Mark B.
    Tolhurst, Stephen R.
    Rapp, David E.
    Seip, Ralf
    Sanghvi, Narendra
    Shalhav, Arieh
    JOURNAL OF UROLOGY, 2009, 181 (02) : 861 - 866
  • [6] Evaluation of a novel laparoscopic camera for characterization of renal ischemia in a porcine model using digital light processing (DLP) hyperspectral imaging
    Olweny, Ephrem O.
    Tan, Yung K.
    Faddegon, Stephen
    Jackson, Neil
    Wehner, Eleanor F.
    Best, Sara L.
    Park, Samuel K.
    Thapa, Abhas
    Cadeddu, Jeffrey A.
    Zuzak, Karel J.
    EMERGING DIGITAL MICROMIRROR DEVICE BASED SYSTEMS AND APPLICATIONS IV, 2012, 8254
  • [7] A Cadaveric Porcine Model for Assessment in Laparoscopic Bariatric Surgery-a Validation Study
    Boza, Camilo
    Varas, Julian
    Buckel, Erwin
    Achurra, Pablo
    Devaud, Nicolas
    Lewis, Trystan
    Aggarwal, Rajesh
    OBESITY SURGERY, 2013, 23 (05) : 589 - 593
  • [8] Single trocar laparoscopic nephrectomy using magnetic anchoring and guidance system in the porcine model
    Zeltser, Ilia S.
    Bergs, Richard
    Fernandez, Raul
    Baker, Linda
    Eberhart, Robert
    Cadeddu, Jeffrey A.
    JOURNAL OF UROLOGY, 2007, 178 (01) : 288 - 291
  • [9] Techniques to improve the limited degree of freedom inherent from laparoscopic surgery during laparoscopic duct-to-mucosa pancreaticojejunostomy
    Lee, Boram
    Yoon, Yoo-Seok
    Han, Ho-Seong
    Lee, Jun Suh
    SURGICAL ONCOLOGY-OXFORD, 2022, 43
  • [10] Evaluation of the ischemic protection efficacy of a laparoscopic renal cooling device using renal transplantation viability assessment criteria in a porcine model
    Navarro, A. P.
    Sohrabi, S.
    Colechin, E.
    Griffiths, C.
    Talbot, D.
    Soomro, N. A.
    JOURNAL OF UROLOGY, 2008, 179 (03) : 1184 - 1189