Application of response surface methodology and desirability approach to optimize the performance of an ultra-low temperature cascade refrigeration system

被引:17
|
作者
Ye, Wenlian [1 ,4 ]
Liu, Fazhu [2 ,3 ]
Yan, Yuqin [1 ]
Liu, Yingwen [2 ]
机构
[1] Lanzhou Univ Technol, Coll Energy & Power Engn, Key Lab Fluid Machinery & Syst, Lanzhou 730000, Gansu, Peoples R China
[2] Xi An Jiao Tong Univ, Sch Energy & Power Engn, Key Lab Thermo Fluid Sci & Engn, MOE, Xian 710049, Shaanxi, Peoples R China
[3] Alphavita Biosci Dalian Co Ltd, Dalian 116000, Liaoning, Peoples R China
[4] Zhe Jiang AMA &HIEN Technol Co Ltd, Yueqing 325600, Zhejiang, Peoples R China
基金
中国国家自然科学基金;
关键词
Cascade refrigeration system; Response surface methodology; Desirability approach; Ultra-low temperature; Multi-objective; LOW-GWP REFRIGERANTS; MULTIOBJECTIVE OPTIMIZATION; ENERGY; EXERGY; R152A; CYCLE;
D O I
10.1016/j.applthermaleng.2023.122130
中图分类号
O414.1 [热力学];
学科分类号
摘要
In this paper, multi-objective optimization of an ultra-low temperature cascade refrigeration system is presented using response surface methodology and desirability approach. Evaporation temperature, high-temperature circuit and low-temperature circuit condensation temperature, cascade temperature difference, and superheat degrees of the compressor suction are chosen as the variables, whereas COP, total exergy destruction and exergy efficiency are adopted as the responses that simultaneously maximizing COP and exergy efficiency while minimizing the exergy destruction. The quadratic models for three responses are obtained after the analysis of variance. The interactive influences of the variables on the responses are indicated. The results present that the maximum deviations between the predicted and actual values for the COP and exergy efficiency are 0.84% and 0.96%, whereas the deviations for the exergy destruction are within +/- 2% accounting for 96% of the samples. Evaporator temperature, condenser temperature, cascade temperature difference, ect. are found to be important parameters which cause great conflicts among the objective functions. A group of optimum values for the input variables are selected and validated. The derivations between predicted modeling and simulation values for the COP, total exergy destruction, and exergy efficiency are -0.604%, 2.886%, and 0.0452%, respectively, indicating that the method is efficient to optimize the performance.
引用
收藏
页数:16
相关论文
共 43 条
  • [41] Numerical study of hydrogen addition on the performance and emission characteristics of compressed natural gas spark-ignition engine using response surface methodology and multi-objective desirability approach
    Boodaghi, Homayoun
    Etghani, Mir Majid
    Sedighi, Korosh
    INTERNATIONAL JOURNAL OF ENGINE RESEARCH, 2021, 22 (08) : 2575 - 2596
  • [42] Performance comparison of ultra-low temperature cascade refrigeration cycles using R717/R170, R717/R41 and R717/R1150 to replace R404A/R23
    Chen, Muqing
    Yang, Qichao
    Shi, Benlin
    Chen, Xiaonan
    Chi, Weikai
    Liu, Guangbin
    Zhao, Yuanyang
    Li, Liansheng
    THERMAL SCIENCE AND ENGINEERING PROGRESS, 2023, 44
  • [43] Highly sensitive and selective pre-column derivatization high-performance liquid chromatography approach for rapid determination of triterpenes oleanolic and ursolic acids and application to Swertia species: Optimization of triterpenic acids extraction and pre-column derivatization using response surface methodology
    Li, Guoliang
    Zhang, Xiaolong
    You, Jinmao
    Song, Cuihua
    Sun, Zhiwei
    Xia, Lian