Application of response surface methodology and desirability approach to optimize the performance of an ultra-low temperature cascade refrigeration system

被引:17
|
作者
Ye, Wenlian [1 ,4 ]
Liu, Fazhu [2 ,3 ]
Yan, Yuqin [1 ]
Liu, Yingwen [2 ]
机构
[1] Lanzhou Univ Technol, Coll Energy & Power Engn, Key Lab Fluid Machinery & Syst, Lanzhou 730000, Gansu, Peoples R China
[2] Xi An Jiao Tong Univ, Sch Energy & Power Engn, Key Lab Thermo Fluid Sci & Engn, MOE, Xian 710049, Shaanxi, Peoples R China
[3] Alphavita Biosci Dalian Co Ltd, Dalian 116000, Liaoning, Peoples R China
[4] Zhe Jiang AMA &HIEN Technol Co Ltd, Yueqing 325600, Zhejiang, Peoples R China
基金
中国国家自然科学基金;
关键词
Cascade refrigeration system; Response surface methodology; Desirability approach; Ultra-low temperature; Multi-objective; LOW-GWP REFRIGERANTS; MULTIOBJECTIVE OPTIMIZATION; ENERGY; EXERGY; R152A; CYCLE;
D O I
10.1016/j.applthermaleng.2023.122130
中图分类号
O414.1 [热力学];
学科分类号
摘要
In this paper, multi-objective optimization of an ultra-low temperature cascade refrigeration system is presented using response surface methodology and desirability approach. Evaporation temperature, high-temperature circuit and low-temperature circuit condensation temperature, cascade temperature difference, and superheat degrees of the compressor suction are chosen as the variables, whereas COP, total exergy destruction and exergy efficiency are adopted as the responses that simultaneously maximizing COP and exergy efficiency while minimizing the exergy destruction. The quadratic models for three responses are obtained after the analysis of variance. The interactive influences of the variables on the responses are indicated. The results present that the maximum deviations between the predicted and actual values for the COP and exergy efficiency are 0.84% and 0.96%, whereas the deviations for the exergy destruction are within +/- 2% accounting for 96% of the samples. Evaporator temperature, condenser temperature, cascade temperature difference, ect. are found to be important parameters which cause great conflicts among the objective functions. A group of optimum values for the input variables are selected and validated. The derivations between predicted modeling and simulation values for the COP, total exergy destruction, and exergy efficiency are -0.604%, 2.886%, and 0.0452%, respectively, indicating that the method is efficient to optimize the performance.
引用
收藏
页数:16
相关论文
共 43 条
  • [21] Experimental investigations on the performance of a thermo-mechanical refrigeration system utilizing ultra-low temperature waste heat sources
    Sleiti, Ahmad K.
    Al-Ammari, Wahib A.
    Al-Khawaja, Mohammed
    ALEXANDRIA ENGINEERING JOURNAL, 2023, 71 : 591 - 607
  • [22] Application of response surface methodology to optimize and investigate the effects of operating conditions on the performance of DMFC
    Taymaz, Imdat
    Akgun, Fehmi
    Benli, Merthan
    ENERGY, 2011, 36 (02) : 1155 - 1160
  • [23] Application of response surface methodology to optimize nitrate removal at low temperature by aerobic denitrificator Pseudomonas strain An-1
    Ren, He-Jun
    Su, Yu
    Wang, Cong
    Hou, Zhi-Min
    Zhou, Ye
    Zhou, Rui
    WATER AND ENVIRONMENT JOURNAL, 2018, 32 (02) : 235 - 241
  • [24] Performance study on a low-temperature absorption-compression cascade refrigeration system driven by low-grade heat
    Xu, Yingjie
    Chen, Guangming
    Wang, Qin
    Han, Xiaohong
    Jiang, Ning
    Deng, Shiming
    ENERGY CONVERSION AND MANAGEMENT, 2016, 119 : 379 - 388
  • [25] Experimental optimization and evaluation of an R600a/R1150 auto-cascade refrigeration systems for ultra-low temperature applications
    Martinez-Angeles, Manel
    Calleja-Anta, Daniel
    Nebot-Andres, Laura
    Llopis, Rodrigo
    RESULTS IN ENGINEERING, 2024, 24
  • [26] Application of response surface methodology to optimize the performance of cyclone separator using mathematical models and CFD simulations
    Brar, Lakhbir Singh
    MATERIALS TODAY-PROCEEDINGS, 2018, 5 (09) : 20426 - 20436
  • [27] Multi-objective optimization of cutting parameters and helix angle for temperature rise and surface roughness using response surface methodology and desirability approach for Al 7075
    Bhirud, N. L.
    Dube, A. S.
    Patil, Amit S. S.
    Bhole, Kiran Suresh
    INTERNATIONAL JOURNAL OF INTERACTIVE DESIGN AND MANUFACTURING - IJIDEM, 2024, 18 (10): : 7095 - 7114
  • [28] COVID 19 vaccine distribution solution to the last mile challenge: Experimental and simulation studies of ultra-low temperature refrigeration system
    Sun, Jian
    Zhang, Mingkan
    Gehl, Anthony
    Fricke, Brian
    Nawaz, Kashif
    Gluesenkamp, Kyle
    Shen, Bo
    Munk, Jeff
    Hagerman, Joe
    Lapsa, Melissa
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2022, 133 (313-325) : 313 - 325
  • [29] Experimental research on the pull-down performance of an ejector enhanced auto-cascade refrigeration system for low-temperature freezer
    Bai, Tao
    Yan, Gang
    Yu, Jianlin
    ENERGY, 2018, 157 : 647 - 657
  • [30] Performance evaluation of NH3/CO2 cascade refrigeration system with ejector subcooling for low-temperature cycle
    Chi, Weikai
    Yang, Qichao
    Chen, Xiaonan
    Liu, Guangbin
    Zhao, Yuanyang
    Li, Liansheng
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2022, 136 : 162 - 171