Parameter-by-parameter estimation method for adsorption isotherm in hydrophobic interaction chromatography

被引:7
|
作者
Yang, Yu-Xiang [1 ]
Chen, Yu-Cheng [1 ]
Yao, Shan-Jing [1 ]
Lin, Dong-Qiang [1 ,2 ]
机构
[1] Zhejiang Univ, Coll Chem & Biol Engn, Key Lab Biomass Chem Engn, Zhejiang Key Lab Smart Biomat,Minist Educ, Hangzhou 310058, Peoples R China
[2] Zhejiang Univ, Coll Chem & Biol Engn, Hangzhou 310058, Peoples R China
基金
国家重点研发计划; 中国国家自然科学基金;
关键词
Hydrophobic interaction chromatography; Parameter estimation; Mechanistic model; Mollerup isotherm; MONOCLONAL-ANTIBODY PURIFICATION; ION-EXCHANGE CHROMATOGRAPHY; PREPARATIVE CHROMATOGRAPHY; PROTEIN ADSORPTION; MODEL PARAMETERS; SEPARATION; OPTIMIZATION; RETENTION; ELUTION; THERMODYNAMICS;
D O I
10.1016/j.chroma.2024.464638
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Hydrophobic interaction chromatography (HIC) is used as a critical polishing step in the downstream processing of biopharmaceuticals. Normally the process development of HIC is a cumbersome and time-consuming task, and the mechanical models can provide a powerful tool to characterize the process, assist process design and accelerate process development. However, the current estimation of model parameters relies on the inverse method, which lacks an efficient and logical parameter estimation strategy. In this study, a parameter-byparameter (PbP) method based on the theoretical derivation and simplifying assumptions was proposed to estimate the Mollerup isotherm parameters for HIC. The method involves three key steps: (1) linear regression (LR) to estimate the salt-protein interaction parameter and the equilibrium constant; (2) linear approximation (LA) to estimate the stoichiometric parameter and the maximum binding capacity; and (3) inverse method to estimate the protein -protein interaction parameter and the kinetic coefficient. The results indicated that the LR step should be used for dilution condition (loading factor below 5%), while the LA step should be conducted when the isotherm is in the transition or nonlinear regions. Six numerical experiments were conducted to implement the PbP method. The results demonstrated that the PbP method developed allows for the systematic estimation of HIC parameters one-by-one, effectively reducing the number of parameters required for inverse method estimation from six to two. This helps prevent non-identifiability of structural parameters. The feasibility of the PbPHIC method was further validated by real-world experiments. Moreover, the PbP method enhances the mechanistic understanding of adsorption behavior of HIC and shows a promising application to other stoichiometric displacement model-derived isotherms.
引用
收藏
页数:14
相关论文
共 50 条
  • [1] Modeling multi-component separation in hydrophobic interaction chromatography with improved parameter-by-parameter estimation method
    Yang, Yu-Xiang
    Lin, Zhi-Yuan
    Chen, Yu-Cheng
    Yao, Shan-Jing
    Lin, Dong-Qiang
    JOURNAL OF CHROMATOGRAPHY A, 2024, 1730
  • [2] Hybrid model development for parameter estimation and process optimization of hydrophobic interaction chromatography
    Ding, Chaoying
    Gerberich, Christopher
    Ierapetritou, Marianthi
    JOURNAL OF CHROMATOGRAPHY A, 2023, 1703
  • [3] Parameter-by-parameter method for steric mass action model of ion exchange chromatography: Theoretical considerations and experimental verification
    Chen, Yu-Cheng
    Yao, Shan-Jing
    Lin, Dong-Qiang
    JOURNAL OF CHROMATOGRAPHY A, 2022, 1680
  • [4] Parameter-by-parameter method for steric mass action model of ion exchange chromatography: Simplified estimation for steric shielding factor
    Chen, Yu-Cheng
    Yao, Shan-Jing
    Lin, Dong-Qiang
    JOURNAL OF CHROMATOGRAPHY A, 2023, 1687
  • [5] Hierarchical Bayesian estimation for adsorption isotherm parameter determination
    Shih, Chunkai
    Park, Jongwoo
    Sholl, David S.
    Realff, Matthew J.
    Yajima, Tomoyuki
    Kawajiri, Yoshiaki
    CHEMICAL ENGINEERING SCIENCE, 2020, 214
  • [6] Modeling of adsorption in hydrophobic interaction chromatography systems using a preferential interaction quadratic isotherm
    Xia, F
    Nagrath, D
    Cramer, SM
    JOURNAL OF CHROMATOGRAPHY A, 2003, 989 (01) : 47 - 54
  • [7] Parameter estimation for the simulation of liquid chromatography
    Altenhoner, U
    Meurer, M
    Strube, J
    SchmidtTraub, H
    JOURNAL OF CHROMATOGRAPHY A, 1997, 769 (01) : 59 - 69
  • [8] Use of MiniColumns for linear isotherm parameter estimation and prediction of benchtop column performance
    Keller, William R.
    Evans, Steven T.
    Ferreira, Gisela
    Robbins, David
    Cramer, Steven M.
    JOURNAL OF CHROMATOGRAPHY A, 2015, 1418 : 94 - 102
  • [9] Parameter estimation method based on parameter function surface
    Bao WeiMin
    Zhang XiaoQin
    Zhao LiPing
    SCIENCE CHINA-TECHNOLOGICAL SCIENCES, 2013, 56 (06) : 1485 - 1498
  • [10] Standardized approach for accurate and reliable model development of ion-exchange chromatography based on parameter-by-parameter method and consideration of extra-column effects
    Chen, Yu-Cheng
    Lu, Hui-Li
    Wang, Rong-Zhu
    Sun, Guo
    Zhang, Xue-Qin
    Liang, Jing-Qi
    Jungbauer, Alois
    Yao, Shan-Jing
    Lin, Dong-Qiang
    BIOTECHNOLOGY JOURNAL, 2024, 19 (03)