A Monte-Carlo simulation study for design of brain dedicated TOF-PET

被引:0
|
作者
Kim, Yeonkyeong [1 ]
Jung, Jiwoong [1 ]
Choi, Yong [1 ]
Leem, Hyuntae [1 ]
Park, Kuntai [1 ]
Lee, Sangwon [1 ]
机构
[1] Sogang Univ, Dept Elect Engn, Mol Imaging Res & Educ MiRe Lab, 35 Baekbeom Ro, Seoul 04107, South Korea
基金
新加坡国家研究基金会;
关键词
Positron emission tomography (PET); Brain PET; Time -of -flight (TOF); Monte Carlo simulation; TIME-OF-FLIGHT; RESOLUTION; SENSITIVITY; SCINTILLATORS; VALIDATION; DETECTORS; UPDATE;
D O I
10.1016/j.nima.2023.168950
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Brain positron emission tomography (PET) has several advantages, including improved sensitivity and spatial resolution compared to whole-body PET, which provides a more accurate diagnosis and observation of metabolic activity in the brain. However, the small diameter and design parameter result in a high parallax error and a random count rate, leading to a deteriorated imaging performance. We designed and evaluated brain PET with various design parameters and applied time-of-flight (TOF) technology to overcome the above problems. The aim of the study was to design an optimal structure of the brain dedicated TOF-PET that provides excellent image quality. This study investigated effects of ring diameter, crystal length, and TOF capability on the performance of brain TOF-PET using a Monte-Carlo simulation. Two brain PET were designed and evaluated, consisting of a commercially available brain PET ring diameter (357 mm) and a smaller ring diameter (257 mm) to verify the effect of ring diameter on the performance of the brain PET. Three brain TOF-PET with different crystal thicknesses (10 mm, 15 mm, and 20 mm) and TOF capacities (180 ps, 220 ps, and 260 ps) were assessed and their performances were compared. An optimization study was also performed to design the optimal structure based on the two simulation results. This study determined the optimal structure of brain-dedicated TOF-PET based on trade-offs and performance differences depending on the parameters of brain PET. As a result, we propose a brain-dedicated TOF-PET with a 15 mm crystal length and 257 mm diameter as the optimal structure. The results of this paper could be used to design PET systems for the brain and other specific organs.
引用
收藏
页数:11
相关论文
共 50 条
  • [41] Design study of dedicated brain PET with polyhedron geometry
    Shi, Han
    Du, Dong
    Xu, JianFeng
    Su, Zhihong
    Peng, Qiyu
    TECHNOLOGY AND HEALTH CARE, 2015, 23 : S615 - S623
  • [42] A MONTE-CARLO SIMULATION OF DIFFUSION AND REACTION IN ZEOLITES
    FRANK, B
    DAHLKE, K
    EMIG, G
    AUST, E
    BROUCEK, R
    NYWLT, M
    MICROPOROUS MATERIALS, 1993, 1 (01): : 43 - 56
  • [43] MONTE-CARLO SIMULATION OF MUSCARINE IN WATER SOLUTION
    MARGHERITIS, C
    ZEITSCHRIFT FUR NATURFORSCHUNG SECTION A-A JOURNAL OF PHYSICAL SCIENCES, 1990, 45 (08): : 1009 - 1015
  • [44] A Monte-Carlo simulation of positron diffusion in solids
    Eichler, S
    Hubner, C
    KrauseRehberg, R
    APPLIED SURFACE SCIENCE, 1997, 116 : 155 - 161
  • [45] A detailed Monte Carlo simulation for the Belle TOF system
    Nam, JW
    Choi, YI
    Kim, DW
    Kim, JH
    Casey, BCK
    Jones, M
    Olsen, SL
    Peters, M
    Rodriguez, JL
    Varner, G
    Zheng, Y
    Gabyshev, N
    Kichimi, H
    Yashima, J
    Zhang, J
    Kim, TH
    Kwon, YJ
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2002, 491 (1-2) : 54 - 68
  • [46] Monte Carlo simulation of the n_TOF Total Absorption Calorimeter
    Guerrero, C.
    Cano-Ott, D.
    Mendoza, E.
    Tain, J. L.
    Algora, A.
    Berthoumieux, E.
    Colonna, N.
    Domingo-Pardo, C.
    Gonzalez-Romero, E.
    Heil, M.
    Jordan, D.
    Kaeppeler, F.
    Lampoudis, C.
    Martinez, T.
    Massimi, C.
    Plag, R.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2012, 671 : 108 - 117
  • [47] Local structure in lithium chloride solution: a Monte-Carlo simulation study
    Rjiba, Abdelkarim
    El Hog, Sahbi
    Jelassi, Jawhar
    Garbouj, Hedi
    Dorbez-Sridi, Rachida
    MOLECULAR SIMULATION, 2021, 47 (14) : 1121 - 1134
  • [48] Monte-Carlo simulations of a high-resolution neutron TOF instrument
    Bernhardt, P
    Demmel, F
    Magerl, A
    PHYSICA B, 2000, 276 : 114 - 115
  • [49] Validation of a PET Monte-Carlo simulator with random events and dead time modeling
    Le Meunier, L
    Mathy, F
    Fagret, PD
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2003, 50 (05) : 1462 - 1468
  • [50] Optimized TOF-PET detector using scintillation crystal array for brain imaging
    Leem, Hyuntae
    Choi, Yong
    Jung, Jiwoong
    Park, Kuntai
    Kim, Yeonkyeong
    Jung, Jin Ho
    NUCLEAR ENGINEERING AND TECHNOLOGY, 2022, 54 (07) : 2592 - 2598