A Monte-Carlo simulation study for design of brain dedicated TOF-PET

被引:0
|
作者
Kim, Yeonkyeong [1 ]
Jung, Jiwoong [1 ]
Choi, Yong [1 ]
Leem, Hyuntae [1 ]
Park, Kuntai [1 ]
Lee, Sangwon [1 ]
机构
[1] Sogang Univ, Dept Elect Engn, Mol Imaging Res & Educ MiRe Lab, 35 Baekbeom Ro, Seoul 04107, South Korea
来源
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT | 2024年 / 1059卷
基金
新加坡国家研究基金会;
关键词
Positron emission tomography (PET); Brain PET; Time -of -flight (TOF); Monte Carlo simulation; TIME-OF-FLIGHT; RESOLUTION; SENSITIVITY; SCINTILLATORS; VALIDATION; DETECTORS; UPDATE;
D O I
10.1016/j.nima.2023.168950
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Brain positron emission tomography (PET) has several advantages, including improved sensitivity and spatial resolution compared to whole-body PET, which provides a more accurate diagnosis and observation of metabolic activity in the brain. However, the small diameter and design parameter result in a high parallax error and a random count rate, leading to a deteriorated imaging performance. We designed and evaluated brain PET with various design parameters and applied time-of-flight (TOF) technology to overcome the above problems. The aim of the study was to design an optimal structure of the brain dedicated TOF-PET that provides excellent image quality. This study investigated effects of ring diameter, crystal length, and TOF capability on the performance of brain TOF-PET using a Monte-Carlo simulation. Two brain PET were designed and evaluated, consisting of a commercially available brain PET ring diameter (357 mm) and a smaller ring diameter (257 mm) to verify the effect of ring diameter on the performance of the brain PET. Three brain TOF-PET with different crystal thicknesses (10 mm, 15 mm, and 20 mm) and TOF capacities (180 ps, 220 ps, and 260 ps) were assessed and their performances were compared. An optimization study was also performed to design the optimal structure based on the two simulation results. This study determined the optimal structure of brain-dedicated TOF-PET based on trade-offs and performance differences depending on the parameters of brain PET. As a result, we propose a brain-dedicated TOF-PET with a 15 mm crystal length and 257 mm diameter as the optimal structure. The results of this paper could be used to design PET systems for the brain and other specific organs.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Simulation Study for Designing a Dedicated Cardiac TOF-PET System
    Oliver, Sandra
    Moliner, Laura
    Ilisie, Victor
    Benlloch, J. M.
    Rodriguez-Alvarez, M. J.
    SENSORS, 2020, 20 (05)
  • [2] Count rate performance of brain-dedicated PET scanners: a Monte Carlo simulation study
    Teimoorisichani, Mohammadreza
    Goertzen, Andrew L.
    PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (21):
  • [3] Design consideration of compact cardiac TOF-PET systems: a simulation study
    Akamatsu, Go
    Tashima, Hideaki
    Takyu, Sodai
    Kang, Han Gyu
    Iwao, Yuma
    Takahashi, Miwako
    Yoshida, Eiji
    Yamaya, Taiga
    PHYSICS IN MEDICINE AND BIOLOGY, 2021, 66 (07):
  • [4] Monte-Carlo simulation for QDIP device design
    Matsukura, Y
    Uchiyama, Y
    Suzuki, R
    Fujii, T
    Kajihara, N
    INFRARED PHYSICS & TECHNOLOGY, 2005, 47 (1-2) : 164 - 168
  • [5] Design and proof of concept of a double-panel TOF-PET system
    Gonzalez-Montoro, Andrea
    Pavon, Noriel
    Barbera, Julio
    Cuarella, Neus
    Gonzalez, Antonio J.
    Jimenez-Serrano, Santiago
    Lucero, Alejandro
    Moliner, Laura
    Sanchez, David
    Vidal, Koldo
    Benlloch, Jose M.
    EJNMMI PHYSICS, 2024, 11 (01):
  • [6] Study of a Cherenkov TOF-PET module
    Korpar, S.
    Dolenec, R.
    Krizan, P.
    Pestotnik, R.
    Stanovnik, A.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2013, 732 : 595 - 598
  • [7] Towards 50 ps TOF-PET for Brain imaging
    Harmon, Eric S.
    Thompson, Michael O.
    Schmidtlein, C. Ross
    Turner, James N.
    Krol, Andrzej
    MEDICAL IMAGING 2019: BIOMEDICAL APPLICATIONS IN MOLECULAR, STRUCTURAL, AND FUNCTIONAL IMAGING, 2019, 10953
  • [8] Design Optimisation of a Flat-Panel, Limited-Angle TOF-PET Scanner: A Simulation Study
    Orehar, Matic
    Dolenec, Rok
    El Fakhri, Georges
    Korpar, Samo
    Krizan, Peter
    Razdevsek, Gasper
    Marin, Thibault
    Zontar, Dejan
    Pestotnik, Rok
    DIAGNOSTICS, 2024, 14 (17)
  • [9] Monte-Carlo Simulation for Mahjong
    Chen, Jr-Chang
    Tang, Shih-Chieh
    Wu, I-Chen
    JOURNAL OF INFORMATION SCIENCE AND ENGINEERING, 2022, 38 (04) : 775 - 790
  • [10] Monte Carlo simulation of digital photon counting PET
    Salvadori, Julien
    Labour, Joey
    Odille, Freddy
    Marie, Pierre-Yves
    Badel, Jean-Noel
    Imbert, Laetitia
    Sarrut, David
    EJNMMI PHYSICS, 2020, 7 (01)