Patients with Low Vision Struggle with Placing Eye Drops and Benefit from an Eye Drop Aid

被引:0
|
作者
Grissom, Nick [1 ]
Gardiner, Stuart K. [2 ]
Rees, Jack P. [1 ]
Sanchez, Facundo G. [1 ,2 ]
Mansberger, Steven L. [1 ,2 ]
Cunningham Jr, Emmett T. [3 ,4 ,5 ]
Burgoyne, Claude F. [2 ]
Rice, Karen [1 ]
Belter, Christina [1 ]
Kinast, Robert M. [1 ,2 ]
机构
[1] Legacy Devers Eye Inst, 1040 NW 22nd Ave,Suite 200, Portland, OR 97210 USA
[2] Devers Eye Inst, Discoveries Sight Res Labs, Portland, OR USA
[3] Calif Pacific Med Ctr, Dept Ophthalmol, San Francisco, CA USA
[4] Stanford Univ, Sch Med, Dept Ophthalmol, Stanford, CA 94305 USA
[5] UCSF Sch Med, Francis I Proctor Fdn, San Francisco, CA USA
来源
OPHTHALMOLOGY GLAUCOMA | 2023年 / 6卷 / 05期
关键词
Adherence; Low vision; Eye Drop Delivery; Eye Drop Guide; Eye Drop Aid; MEDICATION ADHERENCE; DELIVERY AID; INSTILLATION; GLAUCOMA; DEVICE; EFFICACY;
D O I
10.1016/j.ogla.2023.04.004
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To evaluate eye drop self-administration in a low-vision patient population and test whether a nose-pivoted drop delivery device (NPDD, GentleDrop) can improve eye drop delivery in these patients.Design: Repeated-measures case series. Participants: Thirty subjects (58 eyes) with low vision, defined as best-corrected visual acuity worse than 20/ 60 or visual field worse than 20(degrees) in the better-seeing eye.Methods: We video-recorded subjects while self-administering eye drops using their own traditional delivery at baseline, after a standardized teaching, and with an NPDD. Two masked graders independently reviewed each drop delivery. Primary success was defined as the drop reaching the eye without the bottle touching the eye or eyelids. Subjects rated ease-of-use (1-10 scale, 10 = easiest) after each drop delivery and completed a satisfaction survey, which included asking whether subjects could place drops independently (1-5 scale, 5 = most independent).Main Outcome Measures: Logistic-transformed generalized estimating equation regression to compare technique satisfaction, ease-of-use, independence, no contact, and success.Results: Primary success was observed in 30 (52%) of 58 eyes at baseline and increased to 44 eyes (76%) with an NPDD (P = 0.013). Bottle tip contact occurred in 23 (40%) of 58 eyes at baseline and 8 eyes (14%) with an NPDD (P = 0.004). Mean ease-of-use scores were 6.7 +/- 3.1 at baseline and 8.3 +/- 1.8 (P < 0.001) with an NPDD. Likewise, the NPDD improved success, bottle tip contact, and ease-of-use compared with post-teaching traditional delivery (P < 0.01). Twenty-two (73%) of 30 subjects preferred the NPDD to traditional delivery. Twenty-nine (97%) thought the NPDD was comfortable to use, and all would recommend the device. A subgroup analysis was performed on 16 subjects that self-reported difficulty instilling drops at baseline. The NPDD showed similar results, and it increased confidence in placing drops independently (4.6 +/- 0.9) compared with baseline (2.7 +/- 1.6, P < 0.001). Fifteen (94%) subjects in this subgroup preferred the NPDD.Conclusions: Low-vision subjects struggled to self-administer eye drops. An NPDD can improve bottle tip contact, ease-of-use, satisfaction, and independence. Eye care providers could consider screening low-vision patients about difficulty with eye drop self-administration and recommending eye drop aids. Financial Disclosure(s): Proprietary or commercial disclosure may be found in the Footnotes and Disclo-sures at the end of this article. Ophthalmology Glaucoma 2023;6:501-508 (c) 2023 by the American Academy of Ophthalmology
引用
收藏
页码:501 / 508
页数:8
相关论文
共 50 条
  • [1] The Design and Development of an Eye Drop Aid for Glaucoma Patients
    Srihirun, Janyut
    Poowaruttanawiwit, Prayuth
    JOURNAL OF MEDICAL DEVICES-TRANSACTIONS OF THE ASME, 2021, 15 (02):
  • [2] Innovative bulls eye drop applicator for self-instillation of eye drops
    Taneja, Mukesh
    Chappidi, Kiranmayi
    Ch, Sai Naga Sri Harsha
    Richhariya, Ashutosh
    Mohamed, Ashik
    Rathi, Varsha M.
    CONTACT LENS & ANTERIOR EYE, 2020, 43 (03) : 256 - 260
  • [3] Novel Eye Drop Delivery Aid Improves Outcomes and Satisfaction
    Sanchez, G. Facundo
    Mansberger, L. Steven
    Kung, Yungtai
    Gardiner, K. Stuart
    Burgoyne, F. Claude
    Cunningham, T. Emmett
    Rees, P. Jack
    Jones, P. Emily
    Kinast, M. Robert
    OPHTHALMOLOGY GLAUCOMA, 2021, 4 (05): : 440 - 446
  • [4] Eye Drop Chart for Improvement of Topical Eye Drops Administration and Adherence
    Shim, Kyu Young
    Seo, Sam
    Lee, Soo Jin
    Lee, Chong Eun
    JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY, 2019, 60 (02): : 160 - 168
  • [5] The effect of the Thai "Eye Drop Guide" on success rate of eye drop self-instillation by glaucoma patients
    Sakiyalak, Darin
    Maneephagaphun, Krissana
    Metheetrairat, Ankana
    Ruangvaravate, Ngamkae
    Kitnarong, Naris
    ASIAN BIOMEDICINE, 2014, 8 (02) : 221 - 227
  • [6] Patients' Experience of Using Eye Drop Guide Device to Aid Self-Administration of Glaucoma Medications
    Sakiyalak, Darin
    Kobwanthanakun, Sirinya
    CLINICAL OPHTHALMOLOGY, 2020, 14 : 3781 - 3788
  • [7] Pivoting from Traditional Eye Drop Administration
    Shukla, Aakriti Garg
    Muir, Kelly W.
    Myers, Jonathan S.
    OPHTHALMOLOGY GLAUCOMA, 2021, 4 (05): : 437 - 439
  • [8] Assessment of eye drop instillation technique in glaucoma patients
    Gomes, Beatriz Fiuza
    Paredes, Angela Flores
    Madeira, Nathalia
    Moraes, Haroldo Vieira, Jr.
    Santhiago, Marcony R.
    ARQUIVOS BRASILEIROS DE OFTALMOLOGIA, 2017, 80 (04) : 238 - 241
  • [9] Eye drop instillation technique in patients with glaucoma
    Tatham, A. J.
    Sarodia, U.
    Gatrad, F.
    Awan, A.
    EYE, 2013, 27 (11) : 1293 - 1298
  • [10] A versatile optoelectronic aid for low vision patients
    Dolores Pelaez-Coca, Maria
    Vargas-Martin, Fernando
    Mota, Sonia
    Diaz, Javier
    Ros-Vidal, Eduardo
    OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 2009, 29 (05) : 565 - 572