Functional Benefit and Orthotic Effect of Dorsiflexion-FES in Children with Hemiplegic Cerebral Palsy

被引:0
作者
Segal, Idan [1 ,2 ]
Khamis, Sam [3 ]
Sagie, Liora [1 ]
Genizi, Jacob [4 ,5 ]
Azriel, David [6 ]
Katzenelenbogen, Sharona [1 ]
Fattal-Valevski, Aviva [1 ,7 ]
机构
[1] Tel Aviv Sourasky Med Ctr, Dana Dwek Childrens Hosp, Pediat Neurol Inst, IL-6093246 Tel Aviv, Israel
[2] Emek Med Ctr, Pediat Neurol Unit, IL-1834111 Afula, Israel
[3] Tel Aviv Sourasky Med Ctr, Dana Dwek Childrens Hosp, Dept Pediat Orthopaed, Gait & Mot Anal Lab, IL-6093246 Tel Aviv, Israel
[4] Bnei Zion Med Ctr, Pediat Neurol Unit, IL-3339419 Haifa, Israel
[5] Technion Israel Inst Technol, Rappaport Family Fac Med, IL-3200003 Haifa, Israel
[6] Technion Israel Inst Technol, Fac Ind Engn & Management, IL-3200003 Haifa, Israel
[7] Tel Aviv Univ, Sackler Fac Med, IL-6997801 Tel Aviv, Israel
来源
CHILDREN-BASEL | 2023年 / 10卷 / 03期
关键词
hemiplegia; cerebral palsy; FES; functional benefit; 6-MINUTE WALK TEST; ELECTRICAL-STIMULATION; INTERRATER RELIABILITY; FOOT DROP; GAIT; NEUROPROSTHESIS; KINEMATICS; SCALE;
D O I
10.3390/children10030531
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
Functional electrical stimulation of the ankle dorsiflexor (DF-FES) may have advantages over ankle foot orthoses (AFOs) in managing pediatric cerebral palsy (CP). This study assessed the functional benefit and orthotic effect of DF-FES in children with hemiplegic CP. We conducted an open-label prospective study on children with hemiplegic CP >= 6 years who used DF-FES for five months. The functional benefit was assessed by repeated motor function tests and the measurement of ankle biomechanical parameters. Kinematic and spatiotemporal parameters were assessed by gait analysis after one and five months. The orthotic effect was defined by dorsiflexion >= 0 degrees with DF-FES at either the mid or terminal swing. Among 26 eligible patients, 15 (median age 8.2 years, range 6-15.6) completed the study. After five months of DF-FES use, the results on the Community Balance and Mobility Scale improved, and the distance in the Six-Minute Walk Test decreased (six-point median difference, 95% CI (1.89, 8.1), -30 m, 95% CI (-83.67, -2.6), respectively, p < 0.05) compared to baseline. No significant changes were seen in biomechanical and kinematic parameters. Twelve patients (80%) who showed an orthotic effect at the final gait analysis experienced more supported walking over time, with a trend toward slower walking. We conclude that the continuous use of DF-FES increases postural control and may cause slower but more controlled gait.
引用
收藏
页数:15
相关论文
共 43 条
  • [1] Trends and Technologies in Rehabilitation of Foot Drop: A Systematic Review
    Alnajjar, Fady
    Zaier, Riadh
    Khalid, Sumayya
    Gochoo, Munkhjargal
    [J]. EXPERT REVIEW OF MEDICAL DEVICES, 2021, 18 (01) : 31 - 46
  • [2] Armand S., 2019, HDB HUMAN MOTION, P1
  • [3] An exploratory study of gait and functional outcomes after neuroprosthesis use in children with hemiplegic cerebral palsy
    Bailes, Amy F.
    Caldwell, Cailee
    Clay, Mike
    Tremper, Melissa
    Dunning, Kari
    Long, Jason
    [J]. DISABILITY AND REHABILITATION, 2017, 39 (22) : 2277 - 2285
  • [4] INTERRATER RELIABILITY OF A MODIFIED ASHWORTH SCALE OF MUSCLE SPASTICITY
    BOHANNON, RW
    SMITH, MB
    [J]. PHYSICAL THERAPY, 1987, 67 (02): : 206 - 207
  • [5] Does therapeutic electrical stimulation improve function in children with disabilities? A comprehensive literature review
    Bosques, Glendaliz
    Martin, Rebecca
    McGee, Leah
    Sadowsky, Cristina
    [J]. JOURNAL OF PEDIATRIC REHABILITATION MEDICINE, 2016, 9 (02) : 83 - 99
  • [6] What causes increased passive stiffness of plantarflexor muscle-tendon unit in children with spastic cerebral palsy?
    Boulard, Clement
    Gross, Raphael
    Gautheron, Vincent
    Lapole, Thomas
    [J]. EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2019, 119 (10) : 2151 - 2165
  • [7] Static Ankle Joint Equinus Toward a Standard Definition and Diagnosis
    Charles, James
    Scutter, Sheila D.
    Buckley, Jonathan
    [J]. JOURNAL OF THE AMERICAN PODIATRIC MEDICAL ASSOCIATION, 2010, 100 (03) : 195 - 203
  • [8] A narrative review of manual muscle testing and implications for muscle testing research
    Conable, Katharine M.
    Rosner, Anthony L.
    [J]. JOURNAL OF CHIROPRACTIC MEDICINE, 2011, 10 (03) : 157 - 165
  • [9] Muscle Plasticity and Ankle Control After Repetitive Use of a Functional Electrical Stimulation Device for Foot Drop in Cerebral Palsy
    Damiano, Diane L.
    Prosser, Laura A.
    Curatalo, Lindsey A.
    Alter, Katharine E.
    [J]. NEUROREHABILITATION AND NEURAL REPAIR, 2013, 27 (03) : 200 - 207
  • [10] The efficacy of neuroprosthesis in young hemiplegic patients, measured by three different gait indices: early results
    Danino, Barry
    Khamis, Sam
    Hemo, Yoram
    Batt, Reuven
    Snir, Erel
    Wientroub, Shlomo
    Hayek, Shlomo
    [J]. JOURNAL OF CHILDRENS ORTHOPAEDICS, 2013, 7 (06) : 537 - 542