A multi-factor optimization method based on thermal comfort for building energy performance with natural ventilation

被引:19
作者
Li, Cong [1 ,2 ]
Chen, Youming [1 ,2 ]
机构
[1] Hunan Univ, Coll Civil Engn, Changsha 410082, Hunan, Peoples R China
[2] Hunan Univ, Key Lab Bldg Safety & Energy Efficiency, Minist Educ, Changsha 410082, Hunan, Peoples R China
基金
中国国家自然科学基金;
关键词
Building energy performance; Natural ventilation; Multi-factor optimization method; Thermal comfort; Surrogate model; SUPPORT VECTOR REGRESSION; WIND-TUNNEL EXPERIMENTS; SIMULATION; MODEL;
D O I
10.1016/j.enbuild.2023.112893
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Natural ventilation is one of the most potential passive measures to improve the building energy perfor-mance. This study introduces a multi-factor optimization method for energy performance of buildings with natural ventilation. To maximize the utilization of natural ventilation, this method uses natural-ventilation strategy (Strategy NV) as the air conditioning system operation strategy. In Strategy NV, the air conditioning system is only on when the natural ventilation cannot fulfill the occupants' thermal needs. Two thermal comfort models and airflow network model are combined to obtain Strategy NV. Support vector regression is applied to train a surrogate model which is used to predict the annual energy consumption in Strategy NV. Introducing the surrogate model as objective function, particle swarm opti-mization is used to find the optimal solution. A case study in hot summer and cold winter climate zone is given to verify the feasibility and correctness of this method. The optimal solution has 656 GJ annual energy consumption in Strategy NV, including 254 GJ annual thermal energy consumption. The optimal solution saves annual thermal energy consumption by 21% in Strategy NV comparing with Strategy FT (full time operation strategy within occupied period). The annual thermal energy consumption of the optimal solution in Strategy NV is at least 26% smaller than that of four commonly used building designs in Strategy NV; and it is at least 43% smaller than that of the four commonly used building designs in Strategy FT. The optimal solution has the least total air conditioning hours comparing with the four com-monly used building designs.(c) 2023 Elsevier B.V. All rights reserved.
引用
收藏
页数:13
相关论文
共 50 条
  • [41] Energy and thermal comfort management in a smart building facilitating a microgrid optimization
    Thomas, Dimitrios
    Bagheri, Ali
    Feldheim, Veronique
    Deblecker, Olivier
    Ioakimidis, Christos S.
    IECON 2017 - 43RD ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY, 2017, : 3621 - 3626
  • [43] Thermal Comfort Models Review: Optimizing Ventilation Performance in Natural Ventilated Buildings
    Siew-Chong, Chan
    Ani, Adi Irfan Che
    Ibrahim, N. L. Nik
    2012 INTERNATIONAL CONFERENCE IN HUMANITIES, SOCIAL SCIENCES AND GLOBAL BUSINESS MANAGEMENT (ISSGBM 2012), VOL 7, 2012, 7 : 10 - 15
  • [44] Impacts of HVACR temperature sensor offsets on building energy performance and occupant thermal comfort
    Yoon, Sungmin
    Yu, Yuebin
    Wang, Jiaqiang
    Wang, Peng
    BUILDING SIMULATION, 2019, 12 (02) : 259 - 271
  • [45] Natural ventilation performance of single room building with fluctuating wind speed and thermal mass
    Tan Gang
    JOURNAL OF CENTRAL SOUTH UNIVERSITY, 2012, 19 (03) : 733 - 739
  • [46] A metamodel-based multi-objective optimization method to balance thermal comfort and energy efficiency in a campus gymnasium
    Yue, Naihua
    Li, Lingling
    Morandi, Alessandro
    Zhao, Yang
    ENERGY AND BUILDINGS, 2021, 253
  • [47] Thermal Performance Analysis and Multi-Factor Optimization of Middle-Deep Coaxial Borehole Heat Exchanger System for Low-Carbon Building Heating
    Liang, Mingshan
    Tu, Jianhua
    Zeng, Lingwen
    Zhang, Zhaoqing
    Cheng, Nan
    Luo, Yongqiang
    SUSTAINABILITY, 2023, 15 (21)
  • [48] A New Multi-Objective Optimization Design Method for Directional Well Trajectory Based on Multi-Factor Constraints
    Qin, Jianyu
    Liu, Luo
    Xue, Liang
    Chen, Xuyue
    Weng, Chengkai
    APPLIED SCIENCES-BASEL, 2022, 12 (21):
  • [49] Building Integrated Shading and Building Applied Photovoltaic System Assessment in the Energy Performance and Thermal Comfort of Office Buildings
    Martinopoulos, Georgios
    Serasidou, Anna
    Antoniadou, Panagiota
    Papadopoulos, Agis M.
    SUSTAINABILITY, 2018, 10 (12)
  • [50] Impact of adaptive thermal comfort criteria on building energy use and cooling equipment size using a multi-objective optimization scheme
    Hamdy, Mohamed
    Hasan, Ala
    Siren, Kai