Detection of obstructive sleep apnea from single-channel ECG signals using a CNN-transformer architecture

被引:34
|
作者
Liu, Hang [1 ,2 ,4 ]
Cui, Shaowei [1 ,2 ,4 ]
Zhao, Xiaohui [3 ]
Cong, Fengyu [1 ,2 ,4 ]
机构
[1] Dalian Univ Technol, Fac Med, Sch Biomed Engn, Dalian, Peoples R China
[2] Dalian Univ Technol, Liaoning Key Lab Integrated Circuit & Biomed Elect, Dalian, Peoples R China
[3] Dalian Municipal Cent Hosp, Dept Resp & Crit Care Med, Dalian, Peoples R China
[4] Univ Jyvaskyla, Fac Informat Technol, Jyvaskyla, Finland
关键词
Obstructive sleep apnea; ECG; Transformer; Deep learning; AUTOMATIC DETECTION; ALGORITHM;
D O I
10.1016/j.bspc.2023.104581
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Obstructive sleep apnea (OSA) is a sleep breathing disorder that can seriously affect the health of patients. The manual diagnostic of OSA through the Polysomnography (PSG) recordings is time-consuming and tedious. Electrocardiogram (ECG) signals have been an alternative for OSA detection. This paper proposes a CNN -Transformer architecture for automatic OSA detection based on single-channel ECG signals. The proposed architecture has two fundamental parts. The first part has the aim of learning a feature representation from ECG signals by using the CNN. The second part consists mainly of the Transformer, a model structure built solely with self-attention mechanism, which is used to model the global temporal context and to perform classification tasks. The effectiveness of the proposed method was validated on Apnea-ECG dataset. The dataset consists of 70 ECG recordings with an annotation for each minute of each recording. The current and adjacent 1-min epochs were combined to form the 3-min input epoch. Besides, experiments were set up with different baseline deep learning models for sequence modeling to verify their effects on classification performance. The per -segment classification accuracy reached 88.2% and the area under the receiver operating characteristic curve (AUC) was 0.95. The per-recording classification accuracy reached 100% and the mean absolute error (MAE) was 4.33. Experimental results demonstrate that the Transformer structure and a 3-min input time window both effectively improve the classification performance. The proposed method can accurately detect OSA from single-channel ECG signals and provides a promising and reliable solution for home portable detection of OSA.
引用
收藏
页数:8
相关论文
共 50 条
  • [41] Self-Supervised Representation Learning-Based OSA Detection Method Using Single-Channel ECG Signals
    Kumar, Chandra Bhushan
    Mondal, Arnab Kumar
    Bhatia, Manvir
    Panigrahi, Bijaya Ketan
    Gandhi, Tapan Kumar
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2023, 72
  • [42] Deep Recurrent Neural Networks for Automatic Detection of Sleep Apnea from Single Channel Respiration Signals
    ElMoaqet, Hisham
    Eid, Mohammad
    Glos, Martin
    Ryalat, Mutaz
    Penzel, Thomas
    SENSORS, 2020, 20 (18) : 1 - 19
  • [43] Evaluation of a Single-Channel Nasal Pressure Device to Assess Obstructive Sleep Apnea Risk in Laboratory and Home Environments
    Crowley, Kate E.
    Rajaratnam, Shantha M. W.
    Shea, Steven A.
    Epstein, Lawrence J.
    Czeisler, Charles A.
    Lockley, Steven W.
    JOURNAL OF CLINICAL SLEEP MEDICINE, 2013, 9 (02): : 109 - 116
  • [44] Detection and severity assessment of obstructive sleep apnea according to deep learning of single-lead electrocardiogram signals
    Zhang, Yitong
    Shi, Yewen
    Su, Yonglong
    Cao, Zine
    Li, Chengjian
    Xie, Yushan
    Niu, Xiaoxin
    Yuan, Yuqi
    Ma, Lina
    Zhu, Simin
    Zhou, Yanuo
    Wang, Zitong
    Hei, XinHong
    Shi, Zhenghao
    Ren, Xiaoyong
    Liu, Haiqin
    JOURNAL OF SLEEP RESEARCH, 2025, 34 (01)
  • [45] Sleep apnea detection from ECG using variational mode decomposition
    Sharma, Hemant
    Sharma, K. K.
    BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2020, 6 (01)
  • [46] Single channel photoplethysmography-based obstructive sleep apnea detection and arrhythmia classification
    Chen, Xiang
    Huang, Jiahao
    Luo, Feifei
    Gao, Shang
    Xi, Min
    Li, Jin
    TECHNOLOGY AND HEALTH CARE, 2022, 30 (02) : 399 - 411
  • [47] An expert system for automated identification of obstructive sleep apnea from single-lead ECG using random under sampling boosting
    Hassan, Ahnaf Rashik
    Haque, Md Aynal
    NEUROCOMPUTING, 2017, 235 : 122 - 130
  • [48] Obstructive Sleep Apnea Detection Using SVM-Based Classification of ECG Signal Features
    Almazaydeh, Laiali
    Elleithy, Khaled
    Faezipour, Miad
    2012 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2012, : 4938 - 4941
  • [49] Automatic Detection of Obstructive Sleep Apnea Events Using a Deep CNN-LSTM Model
    Zhang, Junming
    Tang, Zhen
    Gao, Jinfeng
    Lin, Li
    Liu, Zhiliang
    Wu, Haitao
    Liu, Fang
    Yao, Ruxian
    COMPUTATIONAL INTELLIGENCE AND NEUROSCIENCE, 2021, 2021
  • [50] Obstructive Sleep Apnea Detection based on ECG Signal using Statistical Features of Wavelet Subband
    Rizal, Achmad
    Fauzi, Hilman
    Hadiyoso, Sugondo
    Widadi, Rahmat
    INTERNATIONAL JOURNAL OF ELECTRICAL AND COMPUTER ENGINEERING SYSTEMS, 2022, 13 (10) : 877 - 884