Is Patient-Specific Instrumentation Accurate and Necessary for Open-Wedge High Tibial Osteotomy? A Meta-Analysis

被引:9
|
作者
Pang, Ran [1 ]
Jiang, Zhaohui [1 ]
Xu, Chunlei [1 ]
Shi, Wei [1 ]
Zhang, Xinglong [1 ]
Wan, Xin [1 ]
Bahat, Daniel [2 ]
Li, Hui [1 ,3 ]
Senatov, Fedor [4 ]
Bulygina, Inna [4 ]
Wang, Hu [5 ]
Zhang, Huafeng [1 ,6 ]
Li, Zhijun [1 ,6 ]
机构
[1] Tianjin Med Univ Gen Hosp, Dept Orthopaed, Tianjin, Peoples R China
[2] Cleveland Clin, Dept Orthopaed, Cleveland, OH USA
[3] Natl Univ Sci & Technol MISIS, Ctr Biomed Engn, Moscow, Russia
[4] Tianjin Vocat Coll Sports, Dept Phys Hlth Care & Rehabil, Tianjin, Peoples R China
[5] ITCWM Nankai Hosp, Dept Orthopaed, Tianjin Hosp, Tianjin, Peoples R China
[6] Tianjin Med Univ Gen Hosp, Dept Orthopaed, Tianjin 300052, Peoples R China
基金
中国国家自然科学基金;
关键词
High tibial osteotomy; Meta-analysis; Osteoarthritis; Patient-specific cutting guides; Patient-specific instrumentation; Three-dimensional; CUTTING GUIDES; KNEE; SLOPE;
D O I
10.1111/os.13483
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The purpose of this meta-analysis was to identify if patient-specific instrumentation (PSI) could increase the accuracy of the correction in high tibial osteotomy (HTO) and to explore the assessment indices and the necessity of using a PSI in HTO. A systematic search was carried out using online databases. A total of 466 patients were included in 11 papers that matched the inclusion criteria. To evaluate the accuracy of PSI-assisted HTO, the weight bearing line ratio (WBL%), hip-knee-ankle angle (HKA), mechanical medial proximal tibial angle (mMPTA), and posterior tibial slope angle (PTSA) were measured preoperatively and postoperatively and compared to the designed target values. Statistical analysis was performed after strict data extraction with Review Manager (version 5.4). Significant differences were detected in WBL% (MD = -36.41; 95% CI: -42.30 to -30.53; p < 0.00001), HKA (MD = -9.95; 95% CI: -11.65 to -8.25; p < 0.00001), and mMPTA (MD = -8.40; 95% CI:-10.27 to -6.53; p < 0.00001) but not in PTSA (MD = 0.34; 95% CI: -0.59 to 1.27; p = 0.47) between preoperative and postoperative measurements. There was no significant difference between the designed target values and the postoperative correction values of HKA (MD = 0.14; 95% CI: -0.19 to 0.47; p = 0.41) or mMPTA (MD = 0.11; 95% CI -0.34 to 0.55; p = 0.64). The data show that 3D-based planning of PSI for HTO is both accurate and safe. WBL%, HKA, and mMPTA were the optimal evaluation indicators of coronal plane correction. Sagittal correction is best evaluated by the PTSA. The present study reports that PSI is accurate but not necessary in typical HTO.
引用
收藏
页码:413 / 422
页数:10
相关论文
共 50 条
  • [21] Effect of Computer Navigation on Accuracy and Reliability of Limb Alignment Correction following Open-Wedge High Tibial Osteotomy: A Meta-Analysis
    Han, Seung-Beom
    Kim, Hyun Jung
    Lee, Dae-Hee
    BIOMED RESEARCH INTERNATIONAL, 2017, 2017
  • [22] Sagittal osteotomy inclination in medial open-wedge high tibial osteotomy
    Seung-Yup Lee
    Hong-Chul Lim
    Ji Hoon Bae
    Jae Gyoon Kim
    Se-Hyeok Yun
    Jae-Hyuk Yang
    Jung-Ro Yoon
    Knee Surgery, Sports Traumatology, Arthroscopy, 2017, 25 : 823 - 831
  • [23] Osteotomy configuration of the proximal wedge and analysis of the affecting factors in the medial open-wedge high tibial osteotomy
    Lee, Yong Seuk
    Kang, Jong Yeal
    Lee, Myung Chul
    Elazab, Ashraf
    Choi, Uk Hyun
    Kang, Seo Goo
    Lee, Kyoung Jae
    Lee, Sahnghoon
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2017, 25 (03) : 793 - 799
  • [24] Analysis of changes in tibial torsion angle on open-wedge high tibial osteotomy depending on the osteotomy level
    In-Soo Song
    Junhan Kwon
    Knee Surgery & Related Research, 34
  • [25] Applicability of a modified angular correction measurement method for open-wedge high tibial osteotomy
    Moore, James
    Mychaltchouk, Lydia
    Lavoie, Frederic
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2017, 25 (03) : 846 - 852
  • [26] Feasibility and 3D Planning of a Novel Patient-Specific Instrumentation Technique in Medial Opening-Wedge High Tibial Osteotomy
    Van Genechten, Wouter
    Van Tilborg, Wouter
    Van den Bempt, Maxim
    Van Haver, Annemieke
    Verdonk, Peter
    JOURNAL OF KNEE SURGERY, 2021, 34 (14) : 1560 - 1569
  • [27] Health-related quality of life after open-wedge high tibial osteotomy
    Saier, Tim
    Minzlaff, Philipp
    Feucht, Matthias J.
    Laemmle, Lena
    Burghoff, Maike
    Ihle, Christoph
    Imhoff, Andreas B.
    Hinterwimmer, Stefan
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2017, 25 (03) : 934 - 942
  • [28] Computer-Assisted Open-Wedge High Tibial Osteotomy
    Menetrey, Jacques
    Duthon, Victoria
    Fritschy, Daniel
    OPERATIVE TECHNIQUES IN ORTHOPAEDICS, 2008, 18 (03) : 210 - 214
  • [29] Health-related quality of life after open-wedge high tibial osteotomy
    Tim Saier
    Philipp Minzlaff
    Matthias J. Feucht
    Lena Lämmle
    Maike Burghoff
    Christoph Ihle
    Andreas B. Imhoff
    Stefan Hinterwimmer
    Knee Surgery, Sports Traumatology, Arthroscopy, 2017, 25 : 934 - 942
  • [30] A preoperative simulation of medial open-wedge high tibial osteotomy for predicting postoperative realignment
    Konda, Shoji
    Ishibashi, Teruya
    Tamaki, Masashi
    Tomita, Tetsuya
    FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2023, 11