Sensitivity Study Using Synthetic 3D Image Datasets to Investigate the Effect of Noise Artefacts on Digital Volume Correlation

被引:4
作者
Paraskevoulakos, C. [1 ,3 ]
Ghosh, S. [1 ]
Andriollo, T. [2 ]
Michel, A. [1 ]
机构
[1] Tech Univ Denmark, Dept Environm & Resource Engn, DK-2800 Lyngby, Denmark
[2] Aarhus Univ, Dept Mech & Prod Engn, DK-8000 Aarhus C, Denmark
[3] DTU Sustain, Bldg 118, DK-2800 Lyngby, Denmark
关键词
Digital volume correlation; Noise artefacts; Microstructure; X-RAY TOMOGRAPHY; COMPUTED-TOMOGRAPHY; QUALITY ASSESSMENT; SPECKLE PATTERNS; FRACTURE; DAMAGE; MICROTOMOGRAPHY; DISPLACEMENTS; EVOLUTION; CONCRETE;
D O I
10.1007/s11340-024-01046-0
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Background The potential effect of image noise artefacts on Digital Volume Correlation (DVC) analysis has not been thoroughly studied and, more particularly quantified, even though DVC is an emerging technique widely used in life and material science over the last decade. Objective This paper presents the results of a sensitivity study to shed light on the effect of various noise artefacts on the full-field kinematic fields generated by DVC, both in zero and rigid body motion. Methods Various noise artefacts were studied, including the Gaussian, Salt & Pepper, Speckle noise and embedded Ring Artefacts. A noise-free synthetic microstructure was generated using Discrete Element Modelling (DEM), representing an idealistic case, and acting as the reference dataset for the DVC analysis. Noise artefacts of various intensities (including selected extreme cases) were added to the reference image datasets using MATLAB (R2022) to form the outline of the parametric study. DVC analyses were subsequently conducted employing AVIZO (Thermo Fisher). A subset-based local approach was adopted. A three-dimensional version of the Structural Similarity Index Measure (SSIM) was used to define the similarity between the compared image datasets on each occasion. Sub-pixel rigid body motion was applied on the DEM-generated microstructure and subsequently "poisoned" with noise artefacts to evaluate mean bias and random error of the DVC analysis. Results When the local approach is implemented, the sensitivity study on zero motion data revealed the insignificant effect of the Gaussian, Salt & Pepper, and Speckle noise on the DVC-computed kinematic field. Therefore, the presence of such noise artefacts can be neglected when DVC is executed. On the contrary, Ring Artefacts can pose a considerable challenge and therefore, DVC results need to be evaluated cautiously. A linear relationship between SSIM and the correlation index is observed for the same noise artefacts. Gaussian noise has a pronounced effect on the mean bias error for sub-pixel rigid body motion. Conclusions Generating synthetic image datasets using DEM enabled the investigation of a variety of noise artefacts that potentially affect a DVC analysis. Given that, any microstructure - resembling the material studied - can be simulated and used for a DVC sensitivity analysis, supporting the user in appropriately evaluating the computed kinematic field. Even though the study is conducted for a two-phase material, the method elaborated in this paper also applies to heterogeneous multi-phase materials also. The conclusions drawn are valid within the environment of the AVIZO DVC extension module. Alternative DVC algorithms, utilising different approaches for the cross-correlation and the sub-pixel interpolation methods, need to be investigated.
引用
收藏
页码:595 / 624
页数:30
相关论文
共 57 条
[1]   Impact of micro-scale residual stress on in-situ tensile testing of ductile cast iron: Digital volume correlation vs. model with fully resolved microstructure vs. periodic unit cell [J].
Andriollo, Tito ;
Zhang, Yubin ;
Faester, Soren ;
Thorborg, Jesper ;
Hattel, Jesper .
JOURNAL OF THE MECHANICS AND PHYSICS OF SOLIDS, 2019, 125 :714-735
[2]  
[Anonymous], 2009, P ICT INN 2009 OHR M, DOI DOI 10.1007/978-3-642-10781-8_37
[3]   Synchrotron X-ray characterization of crack strain fields in polygranular graphite [J].
Barhli, S. M. ;
Saucedo-Mora, L. ;
Jordan, M. S. L. ;
Cinar, A. F. ;
Reinhard, C. ;
Mostafavi, M. ;
Marrow, T. J. .
CARBON, 2017, 124 :357-371
[4]   Digital volume correlation: Three-dimensional strain mapping using X-ray tomography [J].
Bay, BK ;
Smith, TS ;
Fyhrie, DP ;
Saad, M .
EXPERIMENTAL MECHANICS, 1999, 39 (03) :217-226
[5]   Experimental quantification of 3D deformations in sensitive clay during stress-probing [J].
Birmpilis, Georgios ;
Ando, Edward ;
Stamati, Olga ;
Hall, Stephen A. ;
Gerolymatou, Eleni ;
Dijkstra, Jelke .
GEOTECHNIQUE, 2022, 73 (08) :655-666
[6]   Multiscale X-ray tomography of cementitious materials: A review [J].
Brisard, Sebastien ;
Serdar, Marijana ;
Monteiro, Paulo J. M. .
CEMENT AND CONCRETE RESEARCH, 2020, 128
[7]   Digital Volume Correlation: Review of Progress and Challenges [J].
Buljac, A. ;
Jailin, C. ;
Mendoza, A. ;
Neggers, J. ;
Taillandier-Thomas, T. ;
Bouterf, A. ;
Smaniotto, B. ;
Hild, F. ;
Roux, S. .
EXPERIMENTAL MECHANICS, 2018, 58 (05) :661-708
[8]   Three-dimensional imaging of earth and planetary materials [J].
Carlson, William D. .
EARTH AND PLANETARY SCIENCE LETTERS, 2006, 249 (3-4) :133-147
[9]   DVC-based image subtraction to detect microcracking in lightweight concrete [J].
Chateau, C. ;
Nguyen, T. T. ;
Bornert, M. ;
Yvonnet, J. .
STRAIN, 2018, 54 (05)
[10]   Interlaboratory Study of Digital Volume Correlation Error Due to X-Ray Computed Tomography Equipment and Scan Parameters: an Update from the DVC Challenge [J].
Croom, B. P. ;
Burden, D. ;
Jin, H. ;
Vonk, N. H. ;
Hoefnagels, J. P. M. ;
Smaniotto, B. ;
Hild, F. ;
Quintana, E. ;
Sun, Q. ;
Nie, X. ;
Li, X. .
EXPERIMENTAL MECHANICS, 2021, 61 (02) :395-410