Ceramic-on-Ceramic Total Hip Arthroplasty and Noises: A Prospective Blinded Randomized Controlled Trial of Influence of Component Design

被引:4
作者
Paulsen, Rune T. [1 ,2 ]
Revald, Peter H.
Kjaersgaard-Andersen, Per
Timm, Signe
Varnum, Claus
机构
[1] Lillebaelt Hosp, Dept Orthopaed Surg, Vejle, Denmark
[2] Lillebaelt Hosp, Orthoped, Beridderbakken 4, DK-7100 Vejle, Syddanmark, Denmark
关键词
ceramic-on-ceramic; total hip arthroplasty; noises; squeaking; component designs; QUALITY-OF-LIFE; SQUEAKING; BEARINGS;
D O I
10.1016/j.arth.2023.08.076
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Noises have been associated with ceramic-on-ceramic bearings in total hip arthroplasties. The etiology is multifactorial, but a high prevalence of noises was reported in studies using a specific acetabular component system. We examined if specific ceramic component designs are associated with the prevalence of noises in 2 commonly used component systems. We hypothesized that there would be no difference in noises between the 2 systems. Methods: In this randomized controlled trial, 2 different component designs with ceramic bearings were compared. Inclusion criteria were primary total hip arthroplasties, age between 18 and 65 years, and body mass index less than 35. The primary outcome was prevalence of noises, whereas secondary outcomes consisted of European Quality of Life index, visual analog scale, and University of California and Los Angeles activity scale. Follow-up data were collected at 3 and 12 months postoperatively. Data were available for 91 patients in Group 1 and for 92 patients in Group 2. Preoperative patient characteristics were comparable between groups. Results: At 12-month follow-up, the prevalence of noises was 19% in Group 1 and 14% in Group 2 (P = .41). European Quality of Life index were 0.89 in Group 1 versus 0.90 in Group 2 (P = .42). The visual analog scale was 81 in both groups (P = .88). When evaluating level of activity, University of California and Los Angeles activity scale scores were 8.2 in both groups (P = .92). Conclusion: At 12-month follow-up, there was no difference in the prevalence of noises between the 2 component designs. (c) 2023 The Author(s). Published by Elsevier Inc. This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/).
引用
收藏
页码:734 / 738
页数:5
相关论文
共 22 条
[1]  
Campbell P, 2004, CLIN ORTHOP RELAT R, P98
[2]   Ceramic-on-Ceramic Total Hip Arthroplasty with Large Diameter Heads: A Systematic Review [J].
Castagnini, Francesco ;
Cosentino, Monica ;
Bracci, Giovanni ;
Masetti, Claudio ;
Faldini, Cesare ;
Traina, Francesco .
MEDICAL PRINCIPLES AND PRACTICE, 2021, 30 (01) :29-36
[3]   Articular Noise After THA Using Delta CoC Bearings Has Little Impact on Quality of Life [J].
Chatelet, Jean-Christophe ;
Fessy, Michel-Henri ;
Saffarini, Mo ;
Machenaud, Alain ;
Jacquot, Laurent .
JOURNAL OF ARTHROPLASTY, 2021, 36 (05) :1678-1687
[4]   The 2009 Frank Stinchfield Award "Hip Squeaking'' A Biomechanical Study of Ceramic-on-ceramic Bearing Surfaces [J].
Chevillotte, Christophe ;
Trousdale, Robert T. ;
Chen, Qingshan ;
Guyen, Olivier ;
An, Kai-Nan .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2010, 468 (02) :345-350
[5]  
Davila-Castrodad Iciar M, 2020, Surg Technol Int, V36, P418
[6]   Health-related quality of life in total hip and total knee arthroplasty - A qualitative and systematic review of the literature [J].
Ethgen, O ;
Bruyere, O ;
Richy, F ;
Dardennes, C ;
Reginster, JY .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2004, 86A (05) :963-974
[7]   Fracture of ceramic heads in total hip replacement [J].
Habermann, B. ;
Ewald, W. ;
Rauschmann, M. ;
Zichner, L. ;
Kurth, A. A. .
ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2006, 126 (07) :464-470
[8]   Health-related quality of life in patients waiting for major joint replacement. A comparison between patients and population controls [J].
Hirvonen, Johanna ;
Blom, Marja ;
Tuominen, Ulla ;
Seitsalo, Seppo ;
Lehto, Matti ;
Paavolainen, Pekka ;
Hietaniemi, Kalevi ;
Rissanen, Pekka ;
Sintonen, Harri .
HEALTH AND QUALITY OF LIFE OUTCOMES, 2006, 4 (1)
[9]  
Schulz Kenneth F, 2010, Open Med, V4, pe60, DOI [10.1016/j.jclinepi.2010.03.004, 10.1136/bmj.c869, 10.1016/j.ijsu.2011.10.001]
[10]   Measurement properties of UCLA Activity Scale for hip and knee arthroplasty patients and translation and cultural adaptation into Danish [J].
Morup-Petersen, Anne ;
Skou, Soren T. ;
Holm, Christina E. ;
Holm, Paetur M. ;
Varnum, Claus ;
Krogsgaard, Michael R. ;
Laursen, Mogens ;
Odgaard, Anders .
ACTA ORTHOPAEDICA, 2021, 92 (06) :681-688