A two-terminal fault location method for gas switch prefire in linear transformer driver

被引:1
|
作者
Wan, Zhenbo [1 ]
Ding, Weidong [1 ]
Sun, Fengju [2 ]
Jiang, Xiaofeng [2 ]
机构
[1] Xi An Jiao Tong Univ, State Key Lab Elect Insulat & Power Equipment, Xian 710049, Peoples R China
[2] Northwest Inst Nucl Technol, State Key Lab Intense Pulsed Radiat Simulat & Effe, Xian 710024, Peoples R China
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 2024年 / 95卷 / 01期
基金
中国国家自然科学基金;
关键词
Location;
D O I
10.1063/5.0187038
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Large-scale linear transformer drivers (LTDs) are composed of numerous high-power gas switches, and switch prefire is a frequent operational fault. To detect and locate the faulty switch accurately and efficiently, a two-terminal location method is proposed. A B-dot sensor is integrated on the gas switch's shell to collect the discharging signal. All the B-dot sensors are connected in parallel through cables of equal length. The fault position can be determined by the time delay of the signals at the two terminals. A diode is inserted between the B-dot sensor's coil and the cable core to ensure low-loss transmission of the signal. Two methods are applied in fault location, including time-of-arrival (TOA) and time reversal (TR). For the TOA method, an energy criterion and a phase criterion are applied and compared. The accuracy of the energy criterion is greatly influenced by the signal-to-noise ratio, while the phase criterion requires a reasonable estimate of the actual delay to account for the impact of phase periodicity. The TR method based on a precise simulation model is established, which demonstrates high precision in location. The TR method has been tested and validated on a single stage LTD module. Moreover, the location method for double switches prefire is discussed theoretically. The method proposed in this paper will be helpful to improve the efficiency of the commissioning, operation, and maintenance of the large-scale LTD devices.
引用
收藏
页数:10
相关论文
共 50 条
  • [41] Performance test method of two-terminal traveling wave fault locator
    Feng T.
    Dong X.
    2018, Electric Power Automation Equipment Press (38): : 114 - 120and128
  • [42] Study on Firing Conditions of Multigap Gas Switch for Fast Linear Transformer Driver
    Liu, Xuandong
    Sun, Fengju
    Liang, Tianxue
    Jiang, Xiaofeng
    Zhang, Qiaogen
    Qiu, Aici
    IEEE TRANSACTIONS ON PLASMA SCIENCE, 2010, 38 (07) : 1670 - 1674
  • [43] Inductance of six-stage gas switch of fast linear transformer driver
    Cong, Peitian
    Sun, Tieping
    Qiu, Aici
    Zeng, Zhengzhong
    Qiangjiguang Yu Lizishu/High Power Laser and Particle Beams, 2012, 24 (08): : 2009 - 2012
  • [44] An Accurate Fault Location Algorithm for Two-Terminal Transmission Lines Combined with Parameter Estimation
    Che, Renfei
    Liang, Jun
    2009 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), VOLS 1-7, 2009, : 1953 - 1956
  • [45] An improved two-terminal numerical algorithm for fault location estimation considering shunt capacitance
    Kim, H. H.
    Lee, C. J.
    Radojevic, Z. M.
    Park, J. B.
    Shin, J. R.
    2006 POWER ENGINEERING SOCIETY GENERAL MEETING, VOLS 1-9, 2006, : 2558 - +
  • [46] Transmission line fault location using two-terminal data without time synchronization
    Silveira, Eduardo G.
    Pereira, Clever
    IEEE TRANSACTIONS ON POWER SYSTEMS, 2007, 22 (01) : 498 - 499
  • [47] A New Algorithm for Two-terminal Fault Location Based on Distributed Parameter Line Model
    Wang, Fan Rong
    Zhou, Hong
    PROCEEDINGS OF THE INTERNATIONAL CONFERENCE ON EDUCATION, MANAGEMENT, COMMERCE AND SOCIETY, 2015, 17 : 368 - 374
  • [48] A Multi-Gap Multi-Channel Gas Switch for the Linear Transformer Driver
    刘轩东
    梁天学
    孙凤举
    姜晓峰
    李佳
    孙福
    邱爱慈
    Plasma Science and Technology, 2009, (06) : 725 - 729
  • [49] A Multi-Gap Multi-Channel Gas Switch for the Linear Transformer Driver
    刘轩东
    梁天学
    孙凤举
    姜晓峰
    李佳
    孙福
    邱爱慈
    Plasma Science and Technology, 2009, 11 (06) : 725 - 729
  • [50] A new way of two-terminal fault location for transmission lines based on strong tracking filter
    Liu Meng
    Liu Suling