A two-terminal fault location method for gas switch prefire in linear transformer driver

被引:1
|
作者
Wan, Zhenbo [1 ]
Ding, Weidong [1 ]
Sun, Fengju [2 ]
Jiang, Xiaofeng [2 ]
机构
[1] Xi An Jiao Tong Univ, State Key Lab Elect Insulat & Power Equipment, Xian 710049, Peoples R China
[2] Northwest Inst Nucl Technol, State Key Lab Intense Pulsed Radiat Simulat & Effe, Xian 710024, Peoples R China
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 2024年 / 95卷 / 01期
基金
中国国家自然科学基金;
关键词
Location;
D O I
10.1063/5.0187038
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Large-scale linear transformer drivers (LTDs) are composed of numerous high-power gas switches, and switch prefire is a frequent operational fault. To detect and locate the faulty switch accurately and efficiently, a two-terminal location method is proposed. A B-dot sensor is integrated on the gas switch's shell to collect the discharging signal. All the B-dot sensors are connected in parallel through cables of equal length. The fault position can be determined by the time delay of the signals at the two terminals. A diode is inserted between the B-dot sensor's coil and the cable core to ensure low-loss transmission of the signal. Two methods are applied in fault location, including time-of-arrival (TOA) and time reversal (TR). For the TOA method, an energy criterion and a phase criterion are applied and compared. The accuracy of the energy criterion is greatly influenced by the signal-to-noise ratio, while the phase criterion requires a reasonable estimate of the actual delay to account for the impact of phase periodicity. The TR method based on a precise simulation model is established, which demonstrates high precision in location. The TR method has been tested and validated on a single stage LTD module. Moreover, the location method for double switches prefire is discussed theoretically. The method proposed in this paper will be helpful to improve the efficiency of the commissioning, operation, and maintenance of the large-scale LTD devices.
引用
收藏
页数:10
相关论文
共 50 条
  • [31] Two-terminal fault location algorithm uninfluenced by parameters of parallel transmission lines
    Xi'an Jiaotong University, Xi'an 710049, China
    Dianli Xitong Zidonghue, 2006, 24 (21-26+32):
  • [32] Accurate Two-Terminal Transmission Line Fault Location Using Traveling Waves
    Lopes, Felipe V.
    Dantas, Karcius M.
    Silva, Kleber M.
    Costa, Flavio B.
    IEEE TRANSACTIONS ON POWER DELIVERY, 2018, 33 (02) : 873 - 880
  • [33] Two-Terminal Algorithm Analysis for Unsymmetrical Fault Location on 110 kV Lines
    Bukvisova, Zuzana
    Orsagova, Jaroslava
    Topolanek, David
    Toman, Petr
    ENERGIES, 2019, 12 (07)
  • [34] Using of current differential protection signals for fault location on two-terminal line
    Rosolowski, Eugeniusz
    Izykowski, Jan
    Saha, Murari M.
    PRZEGLAD ELEKTROTECHNICZNY, 2008, 84 (05): : 9 - 13
  • [35] Research on adaptability to measurement error for several two-terminal fault location algorithms
    Li, Yong-Jian
    Huang, Shao-Ping
    Tang, Jian-Dong
    Dianli Xitong Baohu yu Kongzhi/Power System Protection and Control, 2010, 38 (14): : 134 - 139
  • [36] Novel time-domain fault location algorithm by two-terminal currents
    Gao, Shuping
    Song, Guobing
    Jiao, Zaibing
    Suonan, Jiale
    Hsi-An Chiao Tung Ta Hsueh/Journal of Xi'an Jiaotong University, 2009, 43 (04): : 101 - 105
  • [37] A new two-terminal numerical algorithm for fault location, distance protection, and arcing fault recognition
    Lee, C. J.
    Park, J. B.
    Shin, J. R.
    Radojevie, Z. M.
    IEEE TRANSACTIONS ON POWER SYSTEMS, 2006, 21 (03) : 1460 - 1462
  • [38] The system research of two-terminal fault location analysis based on recording wave
    Yang, Yongfeng
    Sun, Yue
    Ren, Ju
    2010 INTERNATIONAL CONFERENCE ON MANAGEMENT SCIENCE AND ENGINEERING (MSE 2010), VOL 5, 2010, : 193 - 197
  • [39] Characteristics of the Output Voltage Generated by Switch Prefire in Multistage Linear Transformer Drivers
    Wan, Zhenbo
    Ding, Weidong
    Sun, Fengju
    Jiang, Xiaofeng
    Yuan, Qi
    IEEE TRANSACTIONS ON PLASMA SCIENCE, 2024, 52 (04) : 1398 - 1405
  • [40] Transmission line fault location algorithm using trust-region method and two-terminal unsynchronised data
    Li, Xun
    Shi, Shuai-Jun
    Gong, Qing-Wu
    Gaodianya Jishu/High Voltage Engineering, 2010, 36 (02): : 396 - 400