A two-terminal fault location method for gas switch prefire in linear transformer driver

被引:1
|
作者
Wan, Zhenbo [1 ]
Ding, Weidong [1 ]
Sun, Fengju [2 ]
Jiang, Xiaofeng [2 ]
机构
[1] Xi An Jiao Tong Univ, State Key Lab Elect Insulat & Power Equipment, Xian 710049, Peoples R China
[2] Northwest Inst Nucl Technol, State Key Lab Intense Pulsed Radiat Simulat & Effe, Xian 710024, Peoples R China
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 2024年 / 95卷 / 01期
基金
中国国家自然科学基金;
关键词
Location;
D O I
10.1063/5.0187038
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Large-scale linear transformer drivers (LTDs) are composed of numerous high-power gas switches, and switch prefire is a frequent operational fault. To detect and locate the faulty switch accurately and efficiently, a two-terminal location method is proposed. A B-dot sensor is integrated on the gas switch's shell to collect the discharging signal. All the B-dot sensors are connected in parallel through cables of equal length. The fault position can be determined by the time delay of the signals at the two terminals. A diode is inserted between the B-dot sensor's coil and the cable core to ensure low-loss transmission of the signal. Two methods are applied in fault location, including time-of-arrival (TOA) and time reversal (TR). For the TOA method, an energy criterion and a phase criterion are applied and compared. The accuracy of the energy criterion is greatly influenced by the signal-to-noise ratio, while the phase criterion requires a reasonable estimate of the actual delay to account for the impact of phase periodicity. The TR method based on a precise simulation model is established, which demonstrates high precision in location. The TR method has been tested and validated on a single stage LTD module. Moreover, the location method for double switches prefire is discussed theoretically. The method proposed in this paper will be helpful to improve the efficiency of the commissioning, operation, and maintenance of the large-scale LTD devices.
引用
收藏
页数:10
相关论文
共 50 条
  • [21] Two-Terminal Fault Location Method of Distribution Network Based on Adaptive Convolution Neural Network
    Liang, Jiefeng
    Jing, Tianjun
    Niu, Huanna
    Wang, Jiangbo
    IEEE ACCESS, 2020, 8 : 54035 - 54043
  • [22] On Compensating Synchronization Errors in Two-Terminal Based Fault Location Approaches
    Gama, Jessica R.
    Lopes, Felipe V.
    2017 2ND WORKSHOP ON COMMUNICATION NETWORKS AND POWER SYSTEMS (WCNPS), 2017, : 46 - 49
  • [23] A New Practical Fault Location Algorithm for Two-terminal Transmission Lines
    Ma, Zhou
    Li, Xiaoning
    Zhang, Xiaoming
    MANUFACTURING SCIENCE AND TECHNOLOGY, PTS 1-8, 2012, 383-390 : 4377 - +
  • [24] Accurate and comprehensive fault location algorithm for two-terminal transmission lines
    Poudineh-Ebrahimi, Farhad
    Ghazizadeh-Ahsaee, Mahdi
    IET GENERATION TRANSMISSION & DISTRIBUTION, 2018, 12 (19) : 4334 - 4340
  • [25] The cable two-terminal fault location algorithm based on EMD and WVD
    Liu, Yang
    Cao, Yundong
    Hou, Chunguang
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2015, 35 (16): : 4086 - 4093
  • [26] Fault Data Synchronization Using Wavelet for Improving Two-terminal Fault Location Algorithm
    Threevithayanon, Wutthikorn
    Hoonchareon, Naebboon
    2010 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2010,
  • [27] New Fault Impedance Computations for Unsynchronized Two-Terminal Fault-Location Computations
    Yu, Chi-Shan
    Chang, Li-Ren
    Cho, Jr-Ru
    IEEE TRANSACTIONS ON POWER DELIVERY, 2011, 26 (04) : 2879 - 2881
  • [28] Fault location method on two-terminal transmission line using synchronized time information of traveling waves
    Akmaz, Duzgun
    Mamis, Mehmet Salih
    ELECTRICAL ENGINEERING, 2022, 104 (02) : 979 - 990
  • [29] Repetitive operation of multigap gas switch for fast linear transformer driver
    Liu, Xuandong
    Tang, Qijun
    Sun, Fengju
    Yang, Zhuo
    Tan, Xiangyu
    Zhao, Xianping
    Wang, Ke
    Li, Jianming
    Yang, Xiaolei
    Jiang, Xiaofeng
    Zhang, Qiaogen
    Qiu, Aici
    EUROPEAN PHYSICAL JOURNAL-APPLIED PHYSICS, 2012, 60 (03):
  • [30] Fault location method on two-terminal transmission line using synchronized time information of traveling waves
    Düzgün Akmaz
    Mehmet Salih Mamiş
    Electrical Engineering, 2022, 104 : 979 - 990