A two-terminal fault location method for gas switch prefire in linear transformer driver

被引:1
|
作者
Wan, Zhenbo [1 ]
Ding, Weidong [1 ]
Sun, Fengju [2 ]
Jiang, Xiaofeng [2 ]
机构
[1] Xi An Jiao Tong Univ, State Key Lab Elect Insulat & Power Equipment, Xian 710049, Peoples R China
[2] Northwest Inst Nucl Technol, State Key Lab Intense Pulsed Radiat Simulat & Effe, Xian 710024, Peoples R China
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 2024年 / 95卷 / 01期
基金
中国国家自然科学基金;
关键词
Location;
D O I
10.1063/5.0187038
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Large-scale linear transformer drivers (LTDs) are composed of numerous high-power gas switches, and switch prefire is a frequent operational fault. To detect and locate the faulty switch accurately and efficiently, a two-terminal location method is proposed. A B-dot sensor is integrated on the gas switch's shell to collect the discharging signal. All the B-dot sensors are connected in parallel through cables of equal length. The fault position can be determined by the time delay of the signals at the two terminals. A diode is inserted between the B-dot sensor's coil and the cable core to ensure low-loss transmission of the signal. Two methods are applied in fault location, including time-of-arrival (TOA) and time reversal (TR). For the TOA method, an energy criterion and a phase criterion are applied and compared. The accuracy of the energy criterion is greatly influenced by the signal-to-noise ratio, while the phase criterion requires a reasonable estimate of the actual delay to account for the impact of phase periodicity. The TR method based on a precise simulation model is established, which demonstrates high precision in location. The TR method has been tested and validated on a single stage LTD module. Moreover, the location method for double switches prefire is discussed theoretically. The method proposed in this paper will be helpful to improve the efficiency of the commissioning, operation, and maintenance of the large-scale LTD devices.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Unsynchronized two-terminal fault location estimation
    Novosel, D
    Hart, DG
    Udren, E
    Garitty, J
    IEEE TRANSACTIONS ON POWER DELIVERY, 1996, 11 (01) : 130 - 138
  • [2] A novel method for fault location based on two-terminal unsynchronized data
    Li, Xun
    Gong, Qingwu
    Ming, Ruiqing
    2010 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2010,
  • [3] Effect analysis of switch prefire in linear transformer drivers
    State Key Laboratory of Electrical Insulation and Power Equipment, Xi'an Jiaotong University, Xi'an 710049, China
    不详
    IEEE Trans Plasma Sci, 1 (83-89):
  • [4] Effect Analysis of Switch Prefire in Linear Transformer Drivers
    Liu, Peng
    Sun, Fengju
    Wei, Hao
    Jiang, Xiaofeng
    Liu, Xuandong
    Wang, Zhiguo
    Yin, Jiahui
    Liang, Tianxue
    Qiu, Aici
    IEEE TRANSACTIONS ON PLASMA SCIENCE, 2012, 40 (01) : 83 - 89
  • [5] Two-Terminal Fault Location on Unsymmetrical Transmission Lines
    Schulze, Roberto
    Schegner, Peter
    IEEE POWER AND ENERGY SOCIETY GENERAL MEETING 2010, 2010,
  • [6] An Unsynchronized Measurements Correction Method for Two-Terminal Fault-Location Problems
    Yu, Chi-Shan
    IEEE TRANSACTIONS ON POWER DELIVERY, 2010, 25 (03) : 1325 - 1333
  • [7] An iterative two-terminal fault-location method based on unsynchronized phasors
    Dalcastagne, Andre Luis
    Noceti Filho, Sidnei
    Zuern, Hans Helmut
    Seara, Rui
    IEEE TRANSACTIONS ON POWER DELIVERY, 2008, 23 (04) : 2318 - 2329
  • [8] A Fault Location Method for Hybrid Lines Based on Two-terminal Asynchronous Data
    Deng W.
    Lu J.
    Shi J.
    Zhong L.
    He Q.
    Deng, Wenling (727878713@qq.com), 1600, Power System Technology Press (45): : 1574 - 1580
  • [9] Fault location of two-terminal transmission lines with a small fault resistance
    Wu, JK
    2005 IEEE POWER ENGINEERING SOCIETY GENERAL MEETING, VOLS, 1-3, 2005, : 714 - 721
  • [10] Fault location on two-terminal transmission lines based on voltages
    Zamora, I
    Minambres, JF
    Mazon, AJ
    ALvarezIsasi, R
    Lazaro, J
    IEE PROCEEDINGS-GENERATION TRANSMISSION AND DISTRIBUTION, 1996, 143 (01) : 1 - 6