Experimental Investigation of Energy and Exergy Assessment of Vapor Compression Refrigeration Unit Enhanced via Encapsulated Phase Change Material

被引:3
作者
Ismail, Mohamed [1 ,2 ]
Hassan, Hamdy [1 ,3 ]
机构
[1] Suez Univ, Fac Engn, Mech Engn Dept, Suez 41522, Egypt
[2] Egypt Japan Univ Sci & Technol E JUST, Energy Resources Engn Dept, Borg Elarab Alexandria EJUST, Alexandria 21934, Egypt
[3] Assiut Univ, Fac Engn, Mech Power Engn Dept, Assiut 71515, Egypt
关键词
encapsulated phase change material; energy exergy; vapor compression refrigeration unit; NUMERICAL-ANALYSIS; STORAGE; PERFORMANCE; CONDENSER; SYSTEMS;
D O I
10.1002/ente.202300956
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Energy and exergy performance of simple vapor compression refrigeration unit is investigated experimentally with and without coupling heat exchanger of phase change material before the condenser. The hot outside air is cooled before entering the condenser throughout the day by flowing over the cooled phase change material structure that previously solidified during nighttime. Phase change material SP24 is employed because its melting/freezing range is suitable for most selected countries' climates. An experimental set-up of an air-phase change material heat exchanger coupled with the unit is constructed to examine its performance, including pressure-enthalpy curve, coefficient of performance, exergy performance, and power consumption including inflow air temperatures and flow rates impacts. Results affirm that the coefficient of performance, cooling capacity, power usage, and exergy destruction are improved by using phase change material. Compared to the unmodified unit, the maximum percentage of saved power and exergy destruction enhancement for the modified refrigeration unit with phase change material is about 8.8% and 10%, respectively. The maximum coefficient of performance and exergy efficiency rise is about 15.1% and 14.2%, respectively. Increasing the temperature differential across the phase change material heat exchanger, either by increasing inlet temperature or decreasing airflow, enhances the refrigeration unit power saving. Energy and exergy performance of simple vapor compression refrigeration unit (VCRU) is investigated experimentally with and without coupling heat exchanger of phase change material (PCM SP24) before the condenser. The study examines the VCRU performance, including pressure-enthalpy curve, COP, exergy analysis, and power consumption with and without the PCM.image (c) 2023 WILEY-VCH GmbH
引用
收藏
页数:11
相关论文
共 32 条