Usefulness of an auditory aid to improve chest compression rate accuracy during cardiopulmonary resuscitation

被引:0
作者
Genetti, Ashley [1 ]
Llewellyn, Efa A. [1 ,2 ]
机构
[1] Univ Edinburgh, Royal Dick Sch Vet Studies, Edinburgh, Midlothian, Scotland
[2] Univ Edinburgh, Hosp Small Anim, Royal Dick Sch Vet Studies, Easter Bush Campus, Edinburgh EH2 59RG, Midlothian, Scotland
关键词
CPR; high-fidelity simulator; metronome; training; HEART-ASSOCIATION GUIDELINES; HOSPITAL CARDIAC-ARREST; KNOWLEDGE GAP ANALYSIS; CARDIOCEREBRAL RESUSCITATION; RECOVER EVIDENCE; METRONOME; SURVIVAL; IMPLEMENTATION; EDUCATION; OUTCOMES;
D O I
10.1111/vec.13351
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
ObjectiveTo assess compression rate accuracy among veterinarians and registered veterinary nurses (RVNs) without and with an audible aid.DesignProspective study with use of a canine CPR manikin.SettingSmall animal teaching hospital.SubjectsThirty-six participants (20 veterinarians and 16 RVNs).InterventionsEach participant completed the first 2-minute cycle of chest compressions without an auditory aid on a canine CPR manikin. Each participant was then randomized to 1 of 3 auditory aid groups (Group B: Bee Gees "Stayin' Alive"; Group Q: Queen "Another One Bites the Dust"; or Group M: traditional metronome) and then completed a second 2-minute cycle of chest compressions with the instruction to synchronize their compression rate with the beat of the auditory aid. An accurate chest compression rate was defined as obtaining a rate between 100 and 120 compressions per minute (cpm).Measurements and Main ResultsMedian number of compressions administered by participants during Cycle 1 for the first minute was 111 (range 88-140) and for the second minute was 107 (range 80-151), with 25 of 36 (69%) participants obtaining an accurate chest compression rate. Median number of compressions administered during Cycle 2 for the first minute was 110 (range 76-125) and for the second minute was 110 (range 72-125), with 34 of 36 participants (94%) obtaining an accurate chest compression rate. Participants were more likely to obtain an accurate chest compression rate when an auditory aid was present compared to without (McNemar's test; P = 0.013). Subgroup analysis suggested the auditory aid was beneficial in Groups Q and M but not Group B (Kruskal-Wallis with Dunn's post hoc testing; P = 0.014, P = 0.0455, and P = 0.5637, respectively).ConclusionsAn auditory aid was associated with improved chest compression rate accuracy. However, as the auditory aid was not beneficial for Group B participants, our findings suggest that some auditory aids are more helpful than others.
引用
收藏
页码:639 / 647
页数:9
相关论文
共 50 条
[31]   Chest Compression With Personal Protective Equipment During Cardiopulmonary Resuscitation A Randomized Crossover Simulation Study [J].
Chen, Jie ;
Lu, Kai-Zhi ;
Yi, Bin ;
Chen, Yan .
MEDICINE, 2016, 95 (14)
[32]   The effect of inclined step stool on the quality of chest compression during in-hospital cardiopulmonary resuscitation [J].
Yun, Seong-Woo ;
Lee, Byung Kook ;
Jeung, Kyung Woon ;
Park, Sang Wook ;
Choi, Sung Soo ;
Lee, Chang-Hee ;
Ryu, So-Yeon .
AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2014, 32 (08) :851-855
[33]   Real-Time Mobile Device-Assisted Chest Compression During Cardiopulmonary Resuscitation [J].
Sarma, Satyam ;
Bucuti, Hakiza ;
Chitnis, Anurag ;
Klacman, Alex ;
Dantu, Ram .
AMERICAN JOURNAL OF CARDIOLOGY, 2017, 120 (02) :196-200
[34]   Enhancement of capnogram waveform in the presence of chest compression artefact during cardiopulmonary resuscitation [J].
Ruiz de Gauna, Sofia ;
Leturiondo, Mikel ;
Gutierrez, J. Julio ;
Ruiz, Jesus M. ;
Gonzalez-Otero, Digna M. ;
Russell, James K. ;
Daya, Mohamud .
RESUSCITATION, 2018, 133 :53-58
[35]   Feasibility of automated rhythm assessment in chest compression pauses during cardiopulmonary resuscitation [J].
Ruiz, J. ;
Ayala, U. ;
de Gauna, S. Ruiz ;
Irusta, U. ;
Gonzalez-Otero, D. ;
Alonso, E. ;
Kramer-Johansen, J. ;
Eftestol, T. .
RESUSCITATION, 2013, 84 (09) :1223-1228
[36]   Optimal Chest Compression Position for Patients With a Single Ventricle During Cardiopulmonary Resuscitation* [J].
Park, Jung-Bin ;
Song, In-Kyung ;
Lee, Ji-Hyun ;
Kim, Eun-Hee ;
Kim, Hee-Soo ;
Kim, Jin-Tae .
PEDIATRIC CRITICAL CARE MEDICINE, 2016, 17 (04) :303-306
[37]   Does chest compression during cardiopulmonary resuscitation provide sufficient cerebral oxygenation? [J].
Yazar, Mehmet Akif ;
Acikgoz, Mehmet Baris ;
Bayram, Adnan .
TURKISH JOURNAL OF MEDICAL SCIENCES, 2019, 49 (01) :311-317
[38]   Cardiopulmonary resuscitation by bystanders with chest compression only (SOS-KANTO): an observational study [J].
Nagao, Ken ;
Kikushima, Kimio ;
Sakamoto, Tetsuya ;
Koseki, Kazuhide ;
Igarashi, Masaki ;
Ishimatsu, Shinichi ;
Sato, Akira ;
Hori, Shingo ;
Kanesaka, Shigeru ;
Hamabe, Yuichi ;
Saito, Daizo ;
Kitamura, Shinya .
LANCET, 2007, 369 (9565) :920-926
[39]   Direct evaluation of the effect of filtering the chest compression artifacts on the uninterrupted cardiopulmonary resuscitation time [J].
Ruiz, Jesus ;
Ayala, Unai ;
Ruiz de Gauna, Sofia ;
Irusta, Unai ;
Gonzalez-Otero, Digna ;
Aramendi, Elisabete ;
Alonso, Erik ;
Eftestol, Trygve .
AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2013, 31 (06) :910-915
[40]   A higher chest compression rate may be necessary for metronome-guided cardiopulmonary resuscitation [J].
Chung, Tae Nyoung ;
Kim, Sun Wook ;
You, Je Sung ;
Cho, Young Soon ;
Chung, Sung Phil ;
Park, Incheol .
AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2012, 30 (01) :226-230