摘要
ObjectiveTo assess compression rate accuracy among veterinarians and registered veterinary nurses (RVNs) without and with an audible aid.DesignProspective study with use of a canine CPR manikin.SettingSmall animal teaching hospital.SubjectsThirty-six participants (20 veterinarians and 16 RVNs).InterventionsEach participant completed the first 2-minute cycle of chest compressions without an auditory aid on a canine CPR manikin. Each participant was then randomized to 1 of 3 auditory aid groups (Group B: Bee Gees "Stayin' Alive"; Group Q: Queen "Another One Bites the Dust"; or Group M: traditional metronome) and then completed a second 2-minute cycle of chest compressions with the instruction to synchronize their compression rate with the beat of the auditory aid. An accurate chest compression rate was defined as obtaining a rate between 100 and 120 compressions per minute (cpm).Measurements and Main ResultsMedian number of compressions administered by participants during Cycle 1 for the first minute was 111 (range 88-140) and for the second minute was 107 (range 80-151), with 25 of 36 (69%) participants obtaining an accurate chest compression rate. Median number of compressions administered during Cycle 2 for the first minute was 110 (range 76-125) and for the second minute was 110 (range 72-125), with 34 of 36 participants (94%) obtaining an accurate chest compression rate. Participants were more likely to obtain an accurate chest compression rate when an auditory aid was present compared to without (McNemar's test; P = 0.013). Subgroup analysis suggested the auditory aid was beneficial in Groups Q and M but not Group B (Kruskal-Wallis with Dunn's post hoc testing; P = 0.014, P = 0.0455, and P = 0.5637, respectively).ConclusionsAn auditory aid was associated with improved chest compression rate accuracy. However, as the auditory aid was not beneficial for Group B participants, our findings suggest that some auditory aids are more helpful than others.
引用
收藏
页码:639 / 647
页数:9
相关论文
共 50 条
[21]   Cardiopulmonary Resuscitation by Chest Compression Alone: A Reality Check [J].
Papadima, Artemisia ;
Pappas, Apostolos B. ;
Lagoudianakis, Emmanuel E. ;
Kotzadimitriou, Aikaterini ;
Markogiannakis, Haridimos ;
Filis, Konstantinos ;
Vavouranakis, Emmanuel ;
Manouras, Andreas ;
Xanthos, Theodoros ;
Papadimitriou, Lila .
HELLENIC JOURNAL OF CARDIOLOGY, 2010, 51 (01) :55-61
[22]   The assessment of the kinematics of the rescuer in continuous chest compression during a 10-min simulation of cardiopulmonary resuscitation [J].
Bucki, Boguslaw ;
Waniczek, Dariusz ;
Michnik, Robert ;
Karpe, Jacek ;
Bieniek, Andrzej ;
Niczyporuk, Arkadiusz ;
Makarska, Joanna ;
Stepien, Tomasz ;
Myrcik, Dariusz ;
Misiolek, Hanna .
EUROPEAN JOURNAL OF MEDICAL RESEARCH, 2019, 24 (1)
[23]   Feasibility of Biosignal-guided Chest Compression During Cardiopulmonary Resuscitation: A Proofof Concept [J].
Sundermann, Matthew L. ;
Salcido, David D. ;
Koller, Allison C. ;
Menegazzi, James J. .
ACADEMIC EMERGENCY MEDICINE, 2016, 23 (01) :93-97
[24]   Chest Compression Metrics During Manual Cardiopulmonary Resuscitation: a Manikin Study [J].
Ruiz de Gauna, Sofia ;
Gonzalez-Otero, Digna M. ;
Russell, James K. ;
Ruiz, Jesus ;
Pelayo, Sara ;
Saiz, Purificacion .
2017 COMPUTING IN CARDIOLOGY (CINC), 2017, 44
[25]   Simplified dispatcher instructions improve bystander chest compression quality during simulated pediatric resuscitation [J].
Rodriguez, Silvana Arciniegas ;
Sutton, Robert M. ;
Berg, Marc D. ;
Nishisaki, Akira ;
Maltese, Matthew ;
Meaney, Peter A. ;
Niles, Dana E. ;
Leffelman, Jessica ;
Berg, Robert A. ;
Nadkarni, Vinay M. .
RESUSCITATION, 2014, 85 (01) :119-123
[26]   Chest Compression-Only Cardiopulmonary Resuscitation [J].
Ho, Anthony M. -H. ;
Chung, David C. ;
Mizubuti, Glenio B. ;
Wan, Song .
ANESTHESIA AND ANALGESIA, 2016, 123 (05) :1330-1330
[27]   Rationale for continuous chest compression cardiopulmonary resuscitation [J].
Ramaraj, R. ;
Ewy, G. A. .
HEART, 2009, 95 (24) :1978-1982
[28]   Can chest compression release rate or recoil velocity identify rescuer leaning in out-of-hospital cardiopulmonary resuscitation? [J].
Russell, James K. ;
Gonzalez-Otero, Digna M. ;
de Gauna, Sofia Ruiz ;
Daya, Mohamud ;
Ruiz, Jesus .
RESUSCITATION, 2018, 130 :133-137
[29]   Performance of a Dual-Sensor Cardiopulmonary Resuscitation Feedback System in Estimating Compression Depth and Rate During Simulated Chest Compressions [J].
Gould, Jeffrey R. ;
Mostofi, Naghmeh ;
Badin, Jill K. ;
Giacometti, Paolo ;
Lampe, Joshua W. .
JOURNAL OF MEDICAL DEVICES-TRANSACTIONS OF THE ASME, 2025, 19 (02)
[30]   Chest compression during sustained inflation versus 3: 1 chest compression: ventilation ratio during neonatal cardiopulmonary resuscitation: a randomised feasibility trial [J].
Schmolzer, Georg M. ;
Reilly, Megan O. ;
Fray, Caroline ;
van Os, Sylvia ;
Cheung, Po-Yin .
ARCHIVES OF DISEASE IN CHILDHOOD-FETAL AND NEONATAL EDITION, 2018, 103 (05) :F455-F460