Effect of customized abutment taper configuration on bone remodeling and peri-implant tissue around implant-supported single crown: A 3D nonlinear finite element study

被引:4
作者
Poovarodom, Pongsakorn [1 ]
Rungsiyakull, Chaiy [2 ]
Suriyawanakul, Jarupol [3 ]
Li, Qing [4 ]
Sasaki, Keiichi [5 ,6 ]
Yoda, Nobuhiro [6 ]
Rungsiyakull, Pimduen [1 ]
机构
[1] Chiang Mai Univ, Fac Dent, Dept Prosthodont, Chiang Mai 50000, Thailand
[2] Chiang Mai Univ, Fac Engn, Dept Mech Engn, Chiang Mai, Thailand
[3] Khon Kaen Univ, Fac Engn, Dept Mech Engn, Nai Mueang, Thailand
[4] Univ Sydney, Fac Engn, Sch Aerosp Mech & Mechatron Engn, Sydney, Australia
[5] Miyagi Univ, Taiwa, Japan
[6] Tohoku Univ, Grad Sch Dent, Div Prosthet Dent, Sendai, Japan
来源
JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY | 2024年 / 33卷 / 08期
关键词
abutment taper configuration; bone remodeling; dental implant; hydrostatic pressure analysis; peri-implant tissue; SOFT-TISSUE; ORAL IMPLANTS; SURROUNDING BONE; DENTAL IMPLANTS; STRESS-ANALYSIS; SURFACE; DESIGN; OPTIMIZATION; CT; OSSEOINTEGRATION;
D O I
10.1111/jopr.13776
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
PurposeThe optimal configuration of a customized implant abutment plays a crucial role in promoting bone remodeling and maintaining the peri-implant gingival contour. However, the biomechanical effects of abutment configuration on bone remodeling and peri-implant tissue remain unclear. This study aimed to evaluate the influence of abutment taper configurations on bone remodeling and peri-implant tissue.Materials and methodsFive models with different abutment taper configurations (10 degrees, 20 degrees, 30 degrees, 40 degrees, and 50 degrees) were analyzed using finite element analysis (FEA) to evaluate the biomechanical responses in peri-implant bone and the hydrostatic pressure in peri-implant tissue.ResultsThe results demonstrated that the rate of increase in bone density was similar in all models. On the other hand, the hydrostatic pressure in peri-implant gingiva revealed significantly different results. Model 10 degrees showed the highest maximum and volume-averaged hydrostatic pressures (69.31 and 4.5 mmHg), whereas Model 30 degrees demonstrated the lowest values (57.83 and 3.88 mmHg) with the lowest excessive pressure area. The area of excessive hydrostatic pressure decreased in all models as the degree of abutment taper increased from 10 degrees to 30 degrees. In contrast, Models 40 degrees and 50 degrees exhibited greater hydrostatic pressure concentration at the cervical region.ConclusionIn conclusion, the abutment taper configuration had a slight effect on bone remodeling but exerted a significant effect on the peri-implant gingiva above the implant platform via hydrostatic pressure. Significant decreases in greatest and average hydrostatic pressures were observed in the peri-implant tissues of Model 30 degrees. However, the results indicate that implant abutment tapering wider than 40 degrees could result in a larger area of excessive hydrostatic pressure in peri-implant tissue, which could induce gingival recession.
引用
收藏
页码:815 / 823
页数:9
相关论文
共 57 条
[31]   Dental implant induced bone remodeling and associated algorithms [J].
Lin, Daniel ;
Li, Qing ;
Li, Wei ;
Swain, Michael .
JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2009, 2 (05) :410-432
[32]   Scanning electron microscopic observation of microvasculature in periodontium [J].
Matsuo, M ;
Takahashi, K .
MICROSCOPY RESEARCH AND TECHNIQUE, 2002, 56 (01) :3-14
[33]   Stimulating effect of implant loading on surrounding bone -: Comparison of three numerical models and validation by in vivo data [J].
Mellal, A ;
Wiskott, HWA ;
Botsis, J ;
Scherrer, SS ;
Belser, UC .
CLINICAL ORAL IMPLANTS RESEARCH, 2004, 15 (02) :239-248
[34]  
Ming-Lun H., 2010, FINITE ELEM ANAL DES, pCh.2
[35]   Bone ingrowth on the surface of endosseous implants. Part 1: Mathematical model [J].
Moreo, Pedro ;
Manuel Garcia-Aznar, Jose ;
Doblare, Manuel .
JOURNAL OF THEORETICAL BIOLOGY, 2009, 260 (01) :1-12
[36]   Bone ingrowth on the surface of endosseous implants. Part 2: Theoretical and numerical analysis [J].
Moreo, Pedro ;
Manuel Garcia-Aznar, Jose ;
Doblare, Manuel .
JOURNAL OF THEORETICAL BIOLOGY, 2009, 260 (01) :13-26
[37]   THE EFFECT OF AGING AND OVARIECTOMY ON THE VERTEBRAL BONE MASS AND BIOMECHANICAL PROPERTIES OF MATURE RATS [J].
MOSEKILDE, L ;
DANIELSEN, CC ;
KNUDSEN, UB .
BONE, 1993, 14 (01) :1-6
[38]  
Pierrisnard L, 2002, INT J ORAL MAX IMPL, V17, P353
[39]   Effect of gingival height of a titanium base on the biomechanical behavior of 2-piece custom implant abutments: A 3-dimensional nonlinear finite element study [J].
Poovarodom, Pongsakorn ;
Rungsiyakull, Chaiy ;
Suriyawanakul, Jarupol ;
Li, Qing ;
Sasaki, Keiichi ;
Yoda, Nobuhiro ;
Rungsiyakull, Pimduen .
JOURNAL OF PROSTHETIC DENTISTRY, 2023, 130 (03) :380.e1-380.e9
[40]   Effect of implant placement depth on bone remodeling on implant-supported single zirconia abutment crown: A 3D finite element study [J].
Poovarodom, Pongsakorn ;
Rungsiyakull, Chaiy ;
Suriyawanakul, Jarupol ;
Li, Qing ;
Sasaki, Keiichi ;
Yoda, Nobuhiro ;
Rungsiyakull, Pimduen .
JOURNAL OF PROSTHODONTIC RESEARCH, 2023, 67 (02) :278-287