Reliability of the mobile App to measure aerobic training parameters during maximum incremental treadmill test

被引:0
|
作者
Sant' Ana, Jader [1 ]
Sant' Ana, Yasmim Alves [2 ]
Coswig, Victor Silveira [3 ]
Carminatti, Lorival Jose [2 ]
Diefenthaeler, Fernando [1 ]
机构
[1] Univ Fed Santa Catarina, Ctr Desportos, Lab Biomecan, Campus Reitor Joao David Ferreira Lima, BR-88040900 Florianopolis, SC, Brazil
[2] Univ Estado Santa Catarina, Ctr Ciencias Saude & Esporte, Florianopolis, Brazil
[3] Univ Fed Ceara, Inst Educ Fis & Esportes, Fortaleza, Ceara, Brazil
关键词
Aerobic indicators; Physical assessment; Aerobic test; Technological solution; PREDICTING BODY DENSITY; RATE DEFLECTION POINT; HEART-RATE; GENERALIZED EQUATIONS;
D O I
10.1007/s11332-023-01134-z
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
Background Mobile Applications (App) have reshaped approaches to the intervention and monitoring of physical training. The Safe Runner App is an example. However, evidence of the reliability of the Safe Runner App to obtain aerobic parameters still needs to be investigated.AimsThe present study aimed to analyze the accuracy and reproducibility of power parameters and aerobic capacity derived from incremental testing on a treadmill using an application for mobile devices.Methods Twenty participants performed a maximum incremental test and retest. Maximum oxygen consumption (VO2MAX), maximum heart rate (HRMAX), maximum velocity (V-MAX), anaerobic threshold heart rate (HRAT), and anaerobic threshold velocity (V-AT) were estimated. A two-way ANOVA was used for dependent samples or the Friedman test for non-parametric data, and effect size (Cohens-d), intraclass correlation coefficient (ICC), and Bland-Altman were used to verify reliability.Results No differences between the test and retest (p > 0.05) were observed for all variables assessed. The variables VO2MAX (d = 0.05), HRMAX (d = 0.01), and V-MAX (d = 0.05) showed a trivial effect size, while HRAT (d = 0.11) and V-AT (d = 0.16) showed to be trivial/low. The ICC values for VO2MAX (0.996), HRMAX (0.955), HRAT (0.939), V-MAX (0.996), and V-AT (0.913) demonstrated reliability. The Bland-Altman plots demonstrated an agreement of the variables. The variables VO2MAX, HRAT, and V-AT were identical when comparing the Safe Runner App and Excel software.Conclusion The Safe Runner App is reliable in identifying aerobic training parameters.
引用
收藏
页码:509 / 516
页数:8
相关论文
共 50 条
  • [1] Validity And Reliability Of Swimming Incremental Test To Estimate Maximum Aerobic Capacity Of Rats
    Beck, Wladimir R.
    Campesan, Yuri S.
    Gobatto, Claudio A.
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2014, 46 (05): : 942 - 943
  • [2] RELIABILITY OF WALKING ENDURANCE WITH AN INCREMENTAL TREADMILL TEST
    KIRBY, RL
    MARLOW, RW
    ANGIOLOGY, 1987, 38 (07) : 524 - 529
  • [3] RELIABILITY OF WALKING ENDURANCE WITH AN INCREMENTAL TREADMILL TEST
    KIRBY, RL
    MARLOW, RW
    MARBLE, AE
    CLINICAL AND INVESTIGATIVE MEDICINE-MEDECINE CLINIQUE ET EXPERIMENTALE, 1986, 9 (03): : A148 - A148
  • [4] INCREMENTAL GRADED TREADMILL RUN TO EXHAUSTION AS A MEASURE OF AEROBIC POWER
    BOLTER, CP
    COUTTS, P
    JOURNAL OF SPORTS MEDICINE AND PHYSICAL FITNESS, 1987, 27 (04): : 449 - 452
  • [5] Prediction of aerobic power (VO2max) of children and adolescents during an incremental treadmill test
    Machado, Fabiana Andrade
    Denadai, Benedito Sergio
    MOTRIZ-REVISTA DE EDUCACAO FISICA, 2013, 19 (01): : 126 - 132
  • [6] Effect of the pulmonary resistance training device "Elevation training mask 2.0" on physiological parameters and aerobic capacity during a maximal incremental cycling test
    Vasilievich, Volkov Vasiliy
    Borisovich, Miroshnikov Alexander
    Dmitrievich, Formenov Alexander
    PROCEEDINGS OF THE 4TH INTERNATIONAL CONFERENCE ON INNOVATIONS IN SPORTS, TOURISM AND INSTRUCTIONAL SCIENCE (ICISTIS 2019), 2019, 17 : 306 - 308
  • [7] Accuracy of training recommendations based on a treadmill multistage incremental exercise test
    Mugele, Hendrik
    Plummer, Ashley
    Baritello, Omar
    Towe, Maggie
    Brecht, Pia
    Mayer, Frank
    PLOS ONE, 2018, 13 (10):
  • [8] Comparison of Metabolic Characteristics of Physically Active Individuals with Different Training Habits during Incremental Treadmill Test
    Nagy, Dora
    Trunic, Nenad
    Premusz, Viktoria
    Krutek, Laszlo
    Lipcsik, Zoltan
    Acs, Pongrac
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2023, 20 (01)
  • [9] Test-Retest Reliability of Running Economy and Metabolic and Cardiorespiratory Parameters During a Multistage Incremental Treadmill Test in Male Middle- and Long-Distance Runners
    Brady, Aidan J.
    Roantree, Mark
    Egan, Brendan
    INTERNATIONAL JOURNAL OF SPORT NUTRITION AND EXERCISE METABOLISM, 2024, 34 (05) : 307 - 314
  • [10] Reliability of physical performance and thermoregulatory parameters in rats subjected to incremental treadmill running
    Andrade, Pedro V. R.
    Damasceno, William C.
    Hudson, Alexandre S. R.
    Moraes, Michele M.
    Teixeira-Coelho, Francisco
    Albuquerque, Maicon R.
    Wanner, Samuel P.
    JOURNAL OF THERMAL BIOLOGY, 2022, 108