The effect of cartilage dehydration and rehydration on quantitative ultrashort echo time biomarkers

被引:0
|
作者
Wan, Lidi [1 ,2 ]
Searleman, Adam C. [2 ]
Ma, Yajun [2 ]
Wong, Jonathan H. [3 ]
Williams, Judith [3 ]
Murphy, Mark E. [4 ]
Du, Jiang [2 ]
Chang, Eric Y. [2 ,3 ,6 ,7 ]
Tang, Guangyu [1 ,5 ]
机构
[1] Tongji Univ, Sch Med, Shanghai Peoples Hosp 10, Dept Radiol, Shanghai, Peoples R China
[2] Univ Calif San Diego, Dept Radiol, San Diego, CA USA
[3] VA San Diego Healthcare Syst, Radiol Serv, San Diego, CA USA
[4] VA San Diego Healthcare Syst, Orthopaed Surg Serv, San Diego, CA USA
[5] Tongji Univ, Sch Med, Shanghai Peoples Hosp 10, 301 Yanchang Middle Rd, Shanghai 200072, Peoples R China
[6] Univ Calif San Diego, Dept Radiol, 9500 Gilman Dr, San Diego, CA 92093 USA
[7] VA San Diego Healthcare Syst, Radiol Serv, 3350 Jolla Village Dr, San Diego, CA 92161 USA
基金
美国国家卫生研究院;
关键词
Cartilage; fresh; dehydration; rehydration; ultrashort echo time magnetic resonance imaging (UTE-MRI); ARTICULAR-CARTILAGE; ACHILLES-TENDON; MENISCUS; SEQUENCE; MRI; T2;
D O I
10.21037/qims-23-359
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: The effect of dehydration of ex vivo cartilage samples and rehydration with native synovial fluid or normal saline on quantitative ultrashort echo time (UTE) biomarkers are unkonwn. We aimed to investigate the effect of cartilage dehydration-rehydration on UTE biomarkers and to compare the rehydration capabilities of native synovial fluid and normal saline.Methods: A total of 37 cartilage samples were harvested from patients (n=5) who underwent total knee replacement. Fresh cartilage samples were exposed to air to dehydrate for 2 hours after baseline magnetic resonance (MR) scanning, then randomly divided into two groups: one soaking in native synovial fluid (n=17) and the other in normal saline (n=20) to rehydrate for 4 hours. UTE-based biomarkers [T-1, adiabatic T-1? (AdiabT(1?)), macromolecular proton fraction (MMF), magnetization transfer ratio (MTR), and T2*] and sample weights were evaluated for fresh, dehydrated, and rehydrated cartilage samples. Differences and agreements between groups were assessed using the values of fresh cartilage samples as reference standard. Results: Dehydrating in air for 2 hours resulted in significant weight loss (P=0.000). T-1, AdiabT(1?), and T-2* decreased significantly while MMF and MTR increased significantly (all P<0.02). Non-significant differences were observed in cartilage weights after rehydrating in both synovial fluid and normal saline, with P values being 0.204 and 0.769, respectively. There were no significant differences in T-1, AdiabT(1?), MMF, and MTR after rehydrating in synovial fluid (P>0.0167, with Bonferroni correction) while T-2* (P=0.001) still had significant differences compared with fresh samples. However, no significant differences were detected for any of the evaluated UTE biomarkers after rehydrating in normal saline (all P>0.05). No differences were detected in the agreement of UTE biomarker measurements between fresh samples and samples rehydrated with synovial fluid and normal saline.Conclusions: Cartilage dehydration resulted in significant changes in UTE biomarkers. Rehydrating with synovial fluid or normal saline had non-significant effect on all the evaluated UTE biomarkers except T-2* values, which still had significant differences compared with fresh samples after rehydrating with synovial fluid. No significant difference was observed in the rehydration capabilities of native synovial fluid and normal saline.
引用
收藏
页码:6942 / 6951
页数:10
相关论文
共 50 条
  • [41] Quantitative Ultrashort Echo Time (UTE) MRI of Human Cortical Bone: Correlation With Porosity and Biomechanical Properties
    Bae, Won C.
    Chen, Peter C.
    Chung, Christine B.
    Masuda, Koichi
    D'Lima, Darryl
    Du, Jiang
    JOURNAL OF BONE AND MINERAL RESEARCH, 2012, 27 (04) : 848 - 857
  • [42] Correction to: Ultrashort time-to-echo quantitative magnetic resonance imaging of the triangular fibrocartilage: differences in position
    Akitaka Fujisaki
    Takatoshi Aoki
    Hidekuni Narimatsu
    Chie Kuwahara
    Atsushi Nozaki
    Kunitaka Menuki
    Akinori Sakai
    Yukunori Korogi
    European Radiology, 2019, 29 : 3324 - 3324
  • [43] Quantitative ultrashort echo time MR imaging of knee osteochondral junction: An ex vivo feasibility study
    Athertya, Jiyo S.
    Suprana, Arya
    Lo, James
    Lombardi, Alecio F.
    Moazamian, Dina
    Chang, Eric Y.
    Du, Jiang
    Ma, Yajun
    NMR IN BIOMEDICINE, 2024, 37 (12)
  • [44] Ultrashort echo time (UTE) MRI of the spine in thalassaemia
    Hall-Craggs, MA
    Porter, J
    Gatehouse, PD
    Bydder, GM
    BRITISH JOURNAL OF RADIOLOGY, 2004, 77 (914): : 104 - 110
  • [45] CONVENTIONAL AND ULTRASHORT ECHO TIME MRI COMPARED WITH CT
    Nagle, S.
    Francois, C.
    Poranski, M.
    Bell, L.
    Johnson, K.
    Fain, S.
    PEDIATRIC PULMONOLOGY, 2016, 51 : 351 - 352
  • [46] Functional magnetic resonance imaging with an ultrashort echo time
    Kim, Min-Ji
    Jahng, Geon-Ho
    Lee, Soo-Yeol
    Ryu, Chang-Woo
    MEDICAL PHYSICS, 2013, 40 (02)
  • [47] Dual inversion recovery ultrashort echo time (DIR-UTE) imaging and quantification of the zone of calcified cartilage (ZCC)
    Du, J.
    Carl, M.
    Bae, W. C.
    Statum, S.
    Chang, E. Y.
    Bydder, G. M.
    Chung, C. B.
    OSTEOARTHRITIS AND CARTILAGE, 2013, 21 (01) : 77 - 85
  • [48] Magnetic resonance imaging (MRI) of articular cartilage of the knee using ultrashort echo time (uTE) sequences with spiral acquisition
    Goto, Hajimu
    Fujii, Masahiko
    Iwama, Yuki
    Aoyama, Nobukazu
    Ohno, Yoshiharu
    Sugimura, Kazuro
    JOURNAL OF MEDICAL IMAGING AND RADIATION ONCOLOGY, 2012, 56 (03) : 318 - 323
  • [49] Effect of thermal dehydration and rehydration on Na-magadiite structure
    Moura, Aline O.
    Prado, Alexandre G. S.
    JOURNAL OF COLLOID AND INTERFACE SCIENCE, 2009, 330 (02) : 392 - 398
  • [50] Quantitative ultrashort echo time magnetization transfer (UTE-MT) for diagnosis of early cartilage degeneration: comparison with UTE-T2* and T2 mapping
    Yang, Jiawei
    Shao, Hongda
    Ma, Yajun
    Wan, Lidi
    Zhang, Yixuan
    Jiang, Junjie
    Du, Jiang
    Tang, Guangyu
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2020, 10 (01) : 171 - 183