Shoulder Range of Motion Measurement Using Inertial Measurement Unit-Concurrent Validity and Reliability

被引:8
作者
Kaszynski, Jakub [1 ]
Baka, Cezary [1 ]
Bialecka, Martyna [1 ,2 ]
Lubiatowski, Przemyslaw [1 ,3 ]
机构
[1] Rehasport Clin, Gorecka 30, PL-60201 Poznan, Poland
[2] Poznan Univ Tech, Inst Appl Mech, Fac Mech Engn, PL-60965 Poznan, Poland
[3] Poznan Univ Med Sci, Orthopaed Traumatol & Hand Surg Dept, 28 Czerwca 1956 135-147, PL-61545 Poznan, Poland
关键词
IMU; wearable movement sensors; shoulder; range of motion; validation; GONIOMETER;
D O I
10.3390/s23177499
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This study aimed to evaluate the reliability of the RSQ Motion sensor and its validity against the Propriometer and electronic goniometer in measuring the active range of motion (ROM) of the shoulder. The study included 15 volunteers (mean age 24.73 & PLUSMN; 3.31) without any clinical symptoms with no history of trauma, disease, or surgery to the upper limb. Four movements were tested: flexion, abduction, external and internal rotation. Validation was assessed in the full range of active shoulder motion. Reliability was revised in full active ROM, a fixed angle of 90 degrees for flexion and abduction, and 45 degrees for internal and external rotation. Each participant was assessed three times: on the first day by both testers and on the second day only by one of the testers. Goniometer and RSQ Motion sensors showed moderate to excellent correlation for all tested movements (ICC 0.61-0.97, LOA < 23 degrees). Analysis of inter-rater reliability showed good to excellent agreement between both testers (ICC 0.74-0.97, LOA 13-35 degrees). Analysis of intra-rater reliability showed moderate to a good agreement (ICC 0.7-0.88, LOA 22-37 degrees). The shoulder internal and external rotation measurement with RSQ Motion sensors is valid and reliable. There is a high level of inter-rater and intra-rater reliability for the RSQ Motion sensors and Propriometer.
引用
收藏
页数:15
相关论文
共 34 条
[1]   Inter-unit reliability of IMU Step metrics using IMeasureU Blue Trident inertial measurement units for running-based team sport tasks [J].
Armitage, Mark ;
Beato, Marco ;
McErlain-Naylor, Stuart A. .
JOURNAL OF SPORTS SCIENCES, 2021, 39 (13) :1512-1518
[2]   An Inertial Measurement Unit Based Method to Estimate Hip and Knee Joint Kinematics in Team Sport Athletes on the Field [J].
Bastiaansen, Bram J. C. ;
Wilmes, Erik ;
Brink, Michel S. ;
de Ruiter, Cornelis J. ;
Savelsbergh, Geert J. ;
Steijlen, Annemarijn ;
Jansen, Kaspar M. B. ;
van der Helm, Frans C. T. ;
Goedhart, Edwin A. ;
van der Laan, Doris ;
Vegter, Riemer J. K. ;
Lemmink, Koen A. P. M. .
JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2020, (159) :1-8
[3]   The Reliability and Validity of Wearable Inertial Sensors Coupled with the Microsoft Kinect to Measure Shoulder Range-of-Motion [J].
Beshara, Peter ;
Chen, Judy F. ;
Read, Andrew C. ;
Lagadec, Pierre ;
Wang, Tian ;
Walsh, William Robert .
SENSORS, 2020, 20 (24) :1-16
[4]   Shoulder Range of Motion Measurement Using Inertial Measurement Unit-Validation with a Robot Arm [J].
Bialecka, Martyna ;
Gruszczynski, Kacper ;
Cisowski, Pawel ;
Kaszynski, Jakub ;
Baka, Cezary ;
Lubiatowski, Przemyslaw .
SENSORS, 2023, 23 (12)
[5]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[6]   An Inertial Measurement Unit-Based Wireless System for Shoulder Motion Assessment in Patients with Cervical Spinal Cord Injury: A Validation Pilot Study in a Clinical Setting [J].
Bravi, Riccardo ;
Caputo, Stefano ;
Jayousi, Sara ;
Martinelli, Alessio ;
Biotti, Lorenzo ;
Nannini, Ilaria ;
Cohen, Erez James ;
Quarta, Eros ;
Grasso, Stefano ;
Lucchesi, Giacomo ;
Righi, Gabriele ;
Del Popolo, Giulio ;
Mucchi, Lorenzo ;
Minciacchi, Diego .
SENSORS, 2021, 21 (04) :1-25
[7]   POSITION AND ORIENTATION IN-SPACE OF BONES DURING MOVEMENT - ANATOMICAL FRAME DEFINITION AND DETERMINATION [J].
CAPPOZZO, A ;
CATANI, F ;
DELLA CROCE, U ;
LEARDINI, A .
CLINICAL BIOMECHANICS, 1995, 10 (04) :171-178
[8]   Assessment of shoulder range of motion using a commercially available wearable sensor-a validation study [J].
Chan, Li Yi Tammy ;
Chua, Chong Shan ;
Chou, Siaw Meng ;
Seah, Ren Yi Benjamin ;
Huang, Yilun ;
Luo, Yue ;
Dacy, Lincoln ;
Bin Abd Razak, Hamid Rahmatullah .
MHEALTH, 2022, 8
[9]   Validity of Goniometric Elbow Measurements: Comparative Study with a Radiographic Method [J].
Chapleau, Julien ;
Canet, Fanny ;
Petit, Yvan ;
Laflamme, G-Yves ;
Rouleau, Dominique M. .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2011, 469 (11) :3134-3140
[10]   The use of inertial sensors system for human motion analysis [J].
Cuesta-Vargas, Antonio I. ;
Galan-Mercant, Alejandro ;
Williams, Jonathan M. .
PHYSICAL THERAPY REVIEWS, 2010, 15 (06) :462-473