共 50 条
Facile fabrication of naphthalene-functionalized magnetic nanoparticles for efficient extraction of polycyclic aromatic hydrocarbons from environmental water and fish samples
被引:3
|作者:
Peng, Xitian
[1
]
Liu, Li
[1
]
Hu, Xizhou
[1
]
Yan, Wei
[1
]
Zheng, Dan
[1
]
Xia, Zhenzhen
[1
]
Yu, Qiongwei
[2
]
Zhou, Youxiang
[1
]
Xia, Hong
[1
]
Peng, Lijun
[1
]
机构:
[1] Hubei Acad Agr Sci, Inst Agr Qual Stand & Testing Technol Res, Hubei Key Lab Nutr Qual & Safety Agro Prod, Wuhan 430064, Hubei, Peoples R China
[2] Wuhan Univ, Dept Chem, Wuhan 430072, Hubei, Peoples R China
关键词:
Polycyclic aromatic hydrocarbons;
Magnetic solid-phase extraction;
Naphthalene modified magnetic nanoparticles;
Fish;
GC-MS;
MS;
SOLID-PHASE EXTRACTION;
PERFORMANCE LIQUID-CHROMATOGRAPHY;
MICROEXTRACTION;
ENRICHMENT;
COMPOSITE;
ADSORBENT;
D O I:
10.1016/j.chroma.2023.464229
中图分类号:
Q5 [生物化学];
学科分类号:
071010 ;
081704 ;
摘要:
In this study, naphthalene-modified magnetic nanoparticles (Fe3O4@Nap) were simply prepared based on specific chelation interaction between phosphate groups and metal ions on Fe3O4 surface. The resultant Fe3O4@Nap were characterized by FTIR, BET, SEM, TEM, NAM, TGA, and VSM techniques. With Fe3O4@Nap as adsorbent, the polycyclic aromatic hydrocarbons (PAHs) were efficiently extracted by magnetic solid-phase extraction (MSPE) from environmental water and fish samples through the 7C-7C interaction between modified naphthalene groups and PAHs, followed by their determination by GC-MS/MS. The key parameters influencing the extraction efficiency were investigated. Under the optimized conditions, the Fe3O4@Nap-based MSPE/GC-MS/MS method proposed in this paper was evaluated and applied for analyzing PAHs in environmental water and fish samples. And the proposed MSPE/GC-MS/MS method exhibited good linearities for water samples (in the range of 0.1-10 ng/mL, R2 >0.9945) and for fish samples (in the range of 1-100 ng/g, R2 > 0.9905). The limits of detection (LODs) for water and fish samples were 0.004-0.031 ng/mL and 0.07-0.28 ng/g, respectively. Additionally, this method exhibited desirable accuracy and precision. The PAH recovery values from water and fish samples ranged from 81.5% to 109.6% with inter- and intra-day relative standard deviations (RSDs) of less than 12.8%. The MSPE/GC-MS/MS method was successfully applied to the analysis of real environmental water and fish samples. Overall, the newly synthesized Fe3O4@Nap exhibited high sensitivity, specificity, reusability, repeatability, and it could efficiently extract PAHs from environmental water and fish samples by MSPE.
引用
收藏
页数:11
相关论文