T1 maps in upper abdomen: comparison of Look-Locker and B1-corrected variable-flip-angle (VFA) methods

被引:2
作者
Wang, Zhaoqi [1 ]
Chu, Funing [1 ]
Bai, Bingmei [1 ]
Han, Shuai [1 ]
Zhang, Hongkai [1 ]
Yan, Xu [2 ]
Zhang, Shouning [1 ]
Dong, Yafeng [1 ]
Jiang, Lina [1 ]
Zhao, Yan [1 ]
Kamel, Ihab R. R. [3 ]
Li, Hailiang [1 ]
Qu, Jinrong [1 ]
机构
[1] Zhengzhou Univ, Affiliated Canc Hosp, Henan Canc Hosp, Dept Radiol, 127 Dongming Rd, Zhengzhou 450008, Henan, Peoples R China
[2] Siemens Ltd, NEA MR Collaborat, Shanghai 201318, Peoples R China
[3] Johns Hopkins Univ, Sch Med, Dept Radiol, Baltimore, MD 21205 USA
基金
中国国家自然科学基金;
关键词
Magnetic resonance imaging; MR relaxometry; T1; mapping; Liver; Look-locker; B1-corrected VFA; CONTRAST-ENHANCED MRI; MAGNETIC-RESONANCE; CHRONIC HEPATITIS; LIVER-CIRRHOSIS; DIAGNOSIS; ULTRASOUND; ACCURACY;
D O I
10.1007/s42058-022-00114-5
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeT1 mapping has been recognized as a promising tool for quantitative measurements of various tissues that may assist in accurate and tissue specific diagnosis. The purpose of this study was to compare the T1 values of two whole-liver T1 mapping methods, free-breathing Look-Locker and breath-hold B1-corrected variable-flip-angle (VFA) in diagnosing liver cirrhosis, and compare the T1 relaxation time of various upper abdominal organs using two methods.MethodsNon-enhanced T1 mapping with whole-liver coverage was performed on 85 prospectively enrolled suspicious liver tumor patients. Multiple abdominal MRI sequences were obtained. Image quality was assessed by scoring image artifacts on 5-point scale. T1 relaxation time for each organ was recorded. Statistical significance analyzed using Paired t test.ResultsT1 maps of Look-Locker method showed fewer artifacts, with score 5 in all cases compared to 36% in VFA method. There was no significant difference between cirrhotic and non-cirrhotic livers of either left or right lobe in both methods. T1 relaxation time was significantly lower (p < 0.0001) in Look-Locker than VFA method in both lobes of liver, spleen, pancreas, left kidney, right kidney, kidney cortex and medulla, erector spinae and rectus abdominis. No significant difference was found between left and right lobe of liver in both methods. T1 relaxation time of both methods was significantly lower in kidney cortex (p < 0.0001) than medulla on both left and right kidneys.ConclusionsThe choice of Look-Locker or B1-corrected VFA-based T1 mapping may affect T1 values of organs in upper abdomen. Look-Locker showed better image quality and less motion artifacts than B1-corrected VFA method.
引用
收藏
页码:41 / 46
页数:6
相关论文
共 28 条
[1]   Multiparametric magnetic resonance for the non-invasive diagnosis of liver disease [J].
Banerjee, Rajarshi ;
Pavlides, Michael ;
Tunnicliffe, Elizabeth M. ;
Piechnik, Stefan K. ;
Sarania, Nikita ;
Philips, Rachel ;
Collier, Jane D. ;
Booth, Jonathan C. ;
Schneider, Jurgen E. ;
Wang, Lai Mun ;
Delaney, David W. ;
Fleming, Ken A. ;
Robson, Matthew D. ;
Barnes, Eleanor ;
Neubauer, Stefan .
JOURNAL OF HEPATOLOGY, 2014, 60 (01) :69-77
[2]   CLINICAL NMR IMAGING OF THE BRAIN - 140 CASES [J].
BYDDER, GM ;
STEINER, RE ;
YOUNG, IR ;
HALL, AS ;
THOMAS, DJ ;
MARSHALL, J ;
PALLIS, CA ;
LEGG, NJ .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1982, 139 (02) :215-236
[3]   MR relaxometry in chronic liver diseases: Comparison of T1 mapping, T2 mapping, and diffusion-weighted imaging for assessing cirrhosis diagnosis and severity [J].
Cassinotto, Christophe ;
Feldis, Matthieu ;
Vergniol, Julien ;
Mouries, Amaury ;
Cochet, Hubert ;
Lapuyade, Bruno ;
Hocquelet, Arnaud ;
Juanola, Etienne ;
Foucher, Juliette ;
Laurent, Francois ;
De Ledinghen, Victor .
EUROPEAN JOURNAL OF RADIOLOGY, 2015, 84 (08) :1459-1465
[4]   Pharmacokinetic analysis based on dynamic contrast-enhanced MRI for evaluating tumor response to preoperative therapy for oral cancer [J].
Chikui, Toru ;
Kitamoto, Erina ;
Kawano, Shintaro ;
Sugiura, Tsuyoshi ;
Obara, Makoto ;
Simonetti, Arjan W. ;
Hatakenaka, Masamitsu ;
Matsuo, Yoshio ;
Koga, Shoichi ;
Ohga, Masahiro ;
Nakamura, Katsumasa ;
Yoshiura, Kazunori .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2012, 36 (03) :589-597
[5]   Usefulness of T1 mapping on Gd-EOB-DTPA-enhanced MR imaging in assessment of non-alcoholic fatty liver disease [J].
Ding, Ying ;
Rao, Sheng-Xiang ;
Meng, Tao ;
Chen, Caizhong ;
Li, Renchen ;
Zeng, Meng-Su .
EUROPEAN RADIOLOGY, 2014, 24 (04) :959-966
[6]   NUCLEAR MAGNETIC-RESONANCE IMAGING OF THE LIVER - INITIAL EXPERIENCE [J].
DOYLE, FH ;
PENNOCK, JM ;
BANKS, LM ;
MCDONNELL, MJ ;
BYDDER, GM ;
STEINER, RE ;
YOUNG, IR ;
CLARKE, GJ ;
PASMORE, T ;
GILDERDALE, DJ .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1982, 138 (02) :193-200
[7]   RAPID CALCULATION OF T1 USING VARIABLE FLIP ANGLE GRADIENT REFOCUSED IMAGING [J].
FRAM, EK ;
HERFKENS, RJ ;
JOHNSON, GA ;
GLOVER, GH ;
KARIS, JP ;
SHIMAKAWA, A ;
PERKINS, TG ;
PELC, NJ .
MAGNETIC RESONANCE IMAGING, 1987, 5 (03) :201-208
[8]   What is the criterion for differentiating chronic hepatitis from compensated cirrhosis? A prospective study comparing ultrasonography and percutaneous liver biopsy [J].
Gaiani, S ;
Gramantieri, L ;
Venturoli, N ;
Piscaglia, F ;
Siringo, S ;
DErrico, A ;
Zironi, G ;
Grigioni, W ;
Bolondi, L .
JOURNAL OF HEPATOLOGY, 1997, 27 (06) :979-985
[9]   HEPATIC CIRRHOSIS - MAGNETIC-RESONANCE IMAGING [J].
GOLDBERG, HI ;
MOSS, AA ;
STARK, DD ;
MCKERROW, J ;
ENGELSTAD, B ;
BRITO, A .
RADIOLOGY, 1984, 153 (03) :737-739
[10]   Dynamic contrast-enhanced magnetic resonance imaging for localization of recurrent prostate cancer after external beam radiotherapy [J].
Haider, Masoom A. ;
Chung, Peter ;
Sweet, Joan ;
Toi, Ants ;
Jhaveri, Kartik ;
Menard, Cynthia ;
Warde, Padraig ;
Trachtenberg, John ;
Lockwood, Gina ;
Milosevic, Michael .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 70 (02) :425-430