Theoretical Impact of Intraocular Lens Design Variations on the Accuracy of IOL Power Calculations

被引:2
|
作者
Gatinel, Damien [1 ]
Debellemaniere, Guillaume [1 ]
Saad, Alain [1 ]
Rampat, Radhika [1 ]
Malet, Jacques [1 ]
机构
[1] Rothschild Fdn Hosp, Anterior Segment & Refract Surg Dept, 25 Rue Manin, F-75019 Paris, France
关键词
intraocular lens design; intraocular lens constants; lens power calculation formulas; cataract surgery; FORMULA;
D O I
10.3390/jcm12103404
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
To ascertain the theoretical impact of optical design variations of the intraocular lens (IOL) on the accuracy of IOL power formulas based on a single lens constant using a thick lens eye model. This impact was also simulated before and after optimization. We modeled 70 thick-lens pseudophakic eyes implanted with IOLs of symmetrical optical design and power comprised between 0.50 D and 35 D in 0.5-step increments. Modifications of the shape factor resulting in variations in the anterior and posterior radii of an IOL were made, keeping the central thickness and paraxial powers static. Geometry data from three IOL models were also used. Corresponding postoperative spherical equivalent (SE) were computed for different IOL powers and assimilated to a prediction error of the formula due to the sole change in optical design alone. Formula accuracy was studied before and after zeroization on a uniform and non-uniform realistic IOL power distribution. The impact of the incremental change in optic design variability depended on the IOL power. Design modifications theoretically induce an increase in the standard deviation (SD), Mean Absolute Error (MAE), and Root Mean Square (RMS) of the error. The values of these parameters reduce dramatically after zeroization. While the variations in optical design can affect refractive outcomes, especially in short eyes, the zeroization of the mean error theoretically reduces the impact of the IOL's design and power on the accuracy of IOL power calculation.
引用
收藏
页数:19
相关论文
共 50 条
  • [41] Comparison of the accuracy of intraocular lens power calculations for cataract surgery in eyes after phototherapeutic keratectomy
    Yukari Yaguchi
    Kazuno Negishi
    Megumi Saiki
    Hidemasa Torii
    Kazuo Tsubota
    Japanese Journal of Ophthalmology, 2016, 60 : 365 - 372
  • [42] Comparison of the accuracy of intraocular lens power calculations for cataract surgery in eyes after phototherapeutic keratectomy
    Yaguchi, Yukari
    Negishi, Kazuno
    Saiki, Megumi
    Torii, Hidemasa
    Tsubota, Kazuo
    JAPANESE JOURNAL OF OPHTHALMOLOGY, 2016, 60 (05) : 365 - 372
  • [43] INTRAOCULAR-LENS POWER CALCULATIONS FOR MULTIFOCAL INTRAOCULAR LENSES - REPLY
    HOLLADAY, JT
    HOFFER, KJ
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 1993, 115 (02) : 270 - 270
  • [44] Intraoperative biometry for intraocular lens (IOL) power calculation at silicone oil removal
    El-Baha, SM
    El-Samadoni, A
    Idris, HF
    Rashad, KM
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2003, 13 (07) : 622 - 626
  • [45] Intraocular Lens Power Calculations in a Patient with Posterior Keratoconus
    Park, Do Young
    Lim, Dong Hui
    Chung, Tae-Young
    Chung, Eui-Sang
    CORNEA, 2013, 32 (05) : 708 - 711
  • [46] Preclinical Estimation of Constants for Intraocular Lens Power Calculations
    Simpson, Michael
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2021, 62 (08)
  • [47] Effect of corneal aberrations on intraocular lens power calculations
    Canovas, Carmen
    Abenza, Salome
    Alcon, Encarna
    Villegas, Eloy A.
    Marin, Jose M.
    Artal, Pablo
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2012, 38 (08): : 1325 - 1332
  • [48] Preoperative intraocular lens power calculations in problem eyes
    Haigis, Wolfgang
    ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2007, 17 (01): : 45 - 54
  • [49] Intraocular lens power calculations in eyes with pseudoexfoliation syndrome
    Wlaz, Aleksandra
    Kustra, Agnieszka
    Rozegnal-Madej, Agnieszka
    Zarnowski, Tomasz
    SCIENTIFIC REPORTS, 2021, 11 (01)
  • [50] Intraocular lens power calculations: are we stuck in the past?
    Hill, Warren E.
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2009, 37 (08): : 761 - 762