Theoretical Impact of Intraocular Lens Design Variations on the Accuracy of IOL Power Calculations

被引:2
|
作者
Gatinel, Damien [1 ]
Debellemaniere, Guillaume [1 ]
Saad, Alain [1 ]
Rampat, Radhika [1 ]
Malet, Jacques [1 ]
机构
[1] Rothschild Fdn Hosp, Anterior Segment & Refract Surg Dept, 25 Rue Manin, F-75019 Paris, France
关键词
intraocular lens design; intraocular lens constants; lens power calculation formulas; cataract surgery; FORMULA;
D O I
10.3390/jcm12103404
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
To ascertain the theoretical impact of optical design variations of the intraocular lens (IOL) on the accuracy of IOL power formulas based on a single lens constant using a thick lens eye model. This impact was also simulated before and after optimization. We modeled 70 thick-lens pseudophakic eyes implanted with IOLs of symmetrical optical design and power comprised between 0.50 D and 35 D in 0.5-step increments. Modifications of the shape factor resulting in variations in the anterior and posterior radii of an IOL were made, keeping the central thickness and paraxial powers static. Geometry data from three IOL models were also used. Corresponding postoperative spherical equivalent (SE) were computed for different IOL powers and assimilated to a prediction error of the formula due to the sole change in optical design alone. Formula accuracy was studied before and after zeroization on a uniform and non-uniform realistic IOL power distribution. The impact of the incremental change in optic design variability depended on the IOL power. Design modifications theoretically induce an increase in the standard deviation (SD), Mean Absolute Error (MAE), and Root Mean Square (RMS) of the error. The values of these parameters reduce dramatically after zeroization. While the variations in optical design can affect refractive outcomes, especially in short eyes, the zeroization of the mean error theoretically reduces the impact of the IOL's design and power on the accuracy of IOL power calculation.
引用
收藏
页数:19
相关论文
共 50 条
  • [31] INTRAOCULAR-LENS POWER CALCULATIONS FOR MULTIFOCAL INTRAOCULAR LENSES
    HOLLADAY, JT
    HOFFER, KJ
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 1992, 114 (04) : 405 - 408
  • [32] Corneal topography for intraocular lens power calculations
    Alimisi, S
    Miltsakakis, D
    Klyce, S
    JOURNAL OF REFRACTIVE SURGERY, 1996, 12 (02): : S309 - S311
  • [33] Predictive value of regression and theoretical IOL formulas in pediatric intraocular lens implantation
    Andreo, LK
    Wilson, ME
    Saunders, RA
    JOURNAL OF PEDIATRIC OPHTHALMOLOGY & STRABISMUS, 1997, 34 (04) : 240 - 243
  • [34] Impact of Posterior Corneal Surface on Toric Intraocular Lens (IOL) Calculation
    Preussner, Paul-Rolf
    Hoffmann, Peter
    Wahl, Jochen
    CURRENT EYE RESEARCH, 2015, 40 (08) : 809 - 814
  • [35] Accuracy of lens power calculation and centration of an aspheric intraocular lens
    Becker, K. A.
    Holzer, M. P.
    Reuland, A. J.
    Auffarth, G. U.
    OPHTHALMOLOGE, 2006, 103 (10): : 873 - 876
  • [36] Prediction error and accuracy of intraocular lens power calculation in pediatric patient comparing SRK II and Pediatric IOL Calculator
    Azlyn-Azwa Jasman
    Bakiah Shaharuddin
    Raja-Azmi M Noor
    Shatriah Ismail
    Zulkifli A Ghani
    Zunaina Embong
    BMC Ophthalmology, 10
  • [37] Prediction error and accuracy of intraocular lens power calculation in pediatric patient comparing SRK II and Pediatric IOL Calculator
    Jasman, Azlyn-Azwa
    Shaharuddin, Bakiah
    Noor, Raja-Azmi M.
    Ismail, Shatriah
    Ghani, Zulkifli A.
    Embong, Zunaina
    BMC OPHTHALMOLOGY, 2010, 10
  • [38] THE REFRACTIVE ERROR AFTER IMPLANTATION OF A POSTERIOR CHAMBER INTRAOCULAR-LENS - THE ACCURACY OF IOL POWER CALCULATION IN A HOSPITAL PRACTICE
    HOVDING, G
    NATVIK, C
    SLETTEBERG, O
    ACTA OPHTHALMOLOGICA, 1994, 72 (05): : 612 - 616
  • [39] Accuracy of eight intraocular lens power calculation formulas for segmented multifocal intraocular lens
    Zhao, Jing
    Liu, Liang-Ping
    Cheng, Huan-Huan
    Li, Jian-Bing
    Han, Xiao-Tong
    Liu, Yu
    Wu, Ming-Xing
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2020, 13 (09) : 1378 - 1384
  • [40] Accuracy of eight intraocular lens power calculation formulas for segmented multifocal intraocular lens
    Jing Zhao
    Liang-Ping Liu
    Huan-Huan Cheng
    Jian-Bing Li
    Xiao-Tong Han
    Yu Liu
    Ming-Xing Wu
    International Journal of Ophthalmology, 2020, (09) : 1378 - 1384