Theoretical Impact of Intraocular Lens Design Variations on the Accuracy of IOL Power Calculations

被引:2
|
作者
Gatinel, Damien [1 ]
Debellemaniere, Guillaume [1 ]
Saad, Alain [1 ]
Rampat, Radhika [1 ]
Malet, Jacques [1 ]
机构
[1] Rothschild Fdn Hosp, Anterior Segment & Refract Surg Dept, 25 Rue Manin, F-75019 Paris, France
关键词
intraocular lens design; intraocular lens constants; lens power calculation formulas; cataract surgery; FORMULA;
D O I
10.3390/jcm12103404
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
To ascertain the theoretical impact of optical design variations of the intraocular lens (IOL) on the accuracy of IOL power formulas based on a single lens constant using a thick lens eye model. This impact was also simulated before and after optimization. We modeled 70 thick-lens pseudophakic eyes implanted with IOLs of symmetrical optical design and power comprised between 0.50 D and 35 D in 0.5-step increments. Modifications of the shape factor resulting in variations in the anterior and posterior radii of an IOL were made, keeping the central thickness and paraxial powers static. Geometry data from three IOL models were also used. Corresponding postoperative spherical equivalent (SE) were computed for different IOL powers and assimilated to a prediction error of the formula due to the sole change in optical design alone. Formula accuracy was studied before and after zeroization on a uniform and non-uniform realistic IOL power distribution. The impact of the incremental change in optic design variability depended on the IOL power. Design modifications theoretically induce an increase in the standard deviation (SD), Mean Absolute Error (MAE), and Root Mean Square (RMS) of the error. The values of these parameters reduce dramatically after zeroization. While the variations in optical design can affect refractive outcomes, especially in short eyes, the zeroization of the mean error theoretically reduces the impact of the IOL's design and power on the accuracy of IOL power calculation.
引用
收藏
页数:19
相关论文
共 50 条
  • [21] Pediatric intraocular lens power calculations
    O'Hara, Mary A.
    CURRENT OPINION IN OPHTHALMOLOGY, 2012, 23 (05) : 388 - 393
  • [22] CALCULATIONS OF INTRAOCULAR-LENS POWER
    SOMMER, A
    ARCHIVES OF OPHTHALMOLOGY, 1986, 104 (09) : 1271 - 1271
  • [23] Comparison of IOL power calculations by the IOLMaster vs theoretical calculations
    Basu, S
    EYE, 2006, 20 (01) : 90 - 97
  • [24] Accuracy of a universal theoretical formula for power calculation in pediatric intraocular lens implantation
    Eppley, Sarah E.
    Arnold, Benjamin F.
    Tadros, Dina
    Pasricha, Neel
    Campomanes, Alejandra G. de Alba
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2021, 47 (05): : 599 - 605
  • [25] Assessing the interchangeability of keratometry measurements from four biometric devices in intraocular lens power calculations: insights into the predictive accuracy of five modern IOL formulas
    Shan Ma
    Cheng Li
    Jing Sun
    Jun Yang
    Kai Wen
    Xiteng Chen
    Fangyu Zhao
    Xuequan Sun
    Fang Tian
    BMC Ophthalmology, 25 (1)
  • [26] Accuracy of new and standard intraocular lens power calculations formulae in Saudi pediatric patients
    An-Nakhli, Fouad Raja
    TAIWAN JOURNAL OF OPHTHALMOLOGY, 2019, 9 (01) : 37 - 42
  • [27] Accuracy of intraocular lens power calculations in eyes with axial length <22.00 mm
    Day, Alexander C.
    Foster, Paul J.
    Stevens, Julian D.
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2012, 40 (09): : 855 - 862
  • [28] CAN THE ACCURACY OF INTRAOCULAR-LENS CALCULATIONS BE IMPROVED
    MITCHELL, DJ
    OPHTHALMIC SURGERY AND LASERS, 1988, 19 (08): : 549 - 553
  • [29] Reply: Accuracy of intraocular lens calculations in eyes with keratoconus
    Vandevenne, Magali M. S.
    Webers, Valentijn S. C.
    Segers, Maartje H. M.
    Berendschot, Tos T. J. M.
    Zadok, David
    Dickman, Mor M.
    Nuijts, Rudy M. M. A.
    Abulafia, Adi
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2023, 49 (07): : 772 - 772