Ground test results of the microvibration interference for the x-ray microcalorimeter onboard x-ray imaging and spectroscopy mission

被引:1
作者
Hasebe, Takashi [1 ]
Imamura, Ryuta [2 ]
Tsujimoto, Masahiro [3 ]
Awaki, Hisamitsu [2 ]
Chiao, Meng [4 ]
Fujimoto, Ryuichi [5 ]
Hartz, Leslie S. [4 ]
Kilbourne, Caroline A. [4 ]
Sneiderman, Gary A. [4 ]
Takei, Yoh [3 ]
Yasuda, Susumu [6 ]
机构
[1] Univ Tokyo, Kavli Inst Phys & Math Universe WPI, Chiba, Japan
[2] Ehime Univ, Grad Sch Sci & Engn, Ehime, Japan
[3] Japan Aerosp Explorat Agcy, Inst Space & Astronaut Sci, Yokohama, Kanagawa, Japan
[4] NASA, Goddard Space Flight Ctr, Greenbelt, MD USA
[5] Kanazawa Univ, Fac Math & Phys, Kanazawa, Ishikawa, Japan
[6] Japan Aerosp Explorat Agcy, Ibaraki, Japan
关键词
low temperature detector; x-ray microcalorimeter; microvibration interference; XRISM; COOLING SYSTEM; HELIUM DEWAR; CRYOCOOLERS;
D O I
10.1117/1.JATIS.9.1.014003
中图分类号
V [航空、航天];
学科分类号
08 ; 0825 ;
摘要
Resolve is a payload hosting an x-ray microcalorimeter detector operated at 50 mK in the x-ray imaging and spectroscopy mission. It is currently under development as part of an international collaboration and is planned to be launched in 2023. A primary technical concern is the microvibration interference in the sensitive microcalorimeter detector caused by the spacecraft bus components. We conducted a series of verification tests in 2021 to 2022 on the ground, the results of which are reported here. We defined the microvibration interface between the spacecraft and the Resolve instrument. In the instrument-level test, the flight-model hardware was tested against the interface level by injecting it with microvibrations and evaluating the instrument response using the 50 mK stage temperature stability, adiabatic demagnetization refrigerator magnet current consumption rate, and detector noise spectra. We found strong responses when injecting microvibration at similar to 200, 380, and 610 Hz. In the former two cases, the beat between the injected frequency and cryocooler frequency harmonics were observed in the detector noise spectra. In the spacecraft-level test, the acceleration and instrument responses were measured with and without suspension of the entire spacecraft. The reaction wheels (RWs) and inertial reference units (IRUs), two major sources of microvibration among the bus components, were operated. In conclusion, the observed responses of Resolve are within the acceptable levels in the nominal operational range of the RWs and IRUs. There is no evidence that the resultant energy resolution degradation is beyond the current allocation of noise budget.
引用
收藏
页数:13
相关论文
共 20 条
[1]   Cooling system for the Resolve onboard XRISM [J].
Ezoe, Yuichiro ;
Ishisaki, Yoshitaka ;
Fujimoto, Ryuichi ;
Takei, Yoh ;
Horiuchi, Takafumi ;
Tsujimoto, Masahiro ;
Ishikawa, Kumi ;
Yasuda, Susumu ;
Yanagase, Keiichi ;
Shibano, Yasuko ;
Sato, Kosuke ;
Kitamoto, Shunji ;
Yoshida, Seiji ;
Kanao, Keiichi ;
Tsunematsu, Shoji ;
Otsuka, Kiyomi ;
Mizunuma, Syou ;
Isshiki, Masahito ;
Kelley, Richard L. ;
Kilbourne, Calorine A. ;
Porter, Frederick S. ;
DiPirro, Michael J. ;
Shirron, Peter .
CRYOGENICS, 2020, 108
[2]   Performance of the helium dewar and the cryocoolers of the Hitomi soft x-ray spectrometer [J].
Fujimoto, Ryuichi ;
Takei, Yoh ;
Mitsuda, Kazuhisa ;
Yamasaki, Noriko Y. ;
Tsujimoto, Masahiro ;
Koyama, Shu ;
Ishikawa, Kumi ;
Sugita, Hiroyuki ;
Sato, Yoichi ;
Shinozaki, Keisuke ;
Okamoto, Atsushi ;
Kitamoto, Shunji ;
Hoshino, Akio ;
Sato, Kosuke ;
Ezoe, Yuichiro ;
Ishisaki, Yoshitaka ;
Yamada, Shinya ;
Seta, Hiromi ;
Ohashi, Takaya ;
Tamagawa, Toru ;
Noda, Hirofumi ;
Sawada, Makoto ;
Tashiro, Makoto ;
Yatsu, Yoichi ;
Mitsuishi, Ikuyuki ;
Kanao, Kenichi ;
Yoshida, Seiji ;
Miyaoka, Mikio ;
Tsunematsu, Shoji ;
Otsuka, Kiyomi ;
Narasaki, Katsuhiro ;
DiPirro, Michael J. ;
Shirron, Peter J. ;
Sneiderman, Gary A. ;
Kilbourne, Caroline A. ;
Porter, Frederick Scott ;
Chiao, Meng P. ;
Eckart, Megan E. .
JOURNAL OF ASTRONOMICAL TELESCOPES INSTRUMENTS AND SYSTEMS, 2018, 4 (01)
[3]   Mechanical Cryocooler Noise Observed in the Ground Testing of the Resolve X-ray Microcalorimeter Onboard XRISM [J].
Imamura, R. ;
Awaki, H. ;
Tsujimoto, M. ;
Yamada, S. ;
Porter, F. S. ;
Kilbourne, C. A. ;
Kelley, R. L. ;
Takei, Y. .
JOURNAL OF LOW TEMPERATURE PHYSICS, 2023, 211 (5-6) :426-433
[4]   Results of accelerometer monitor in the ground testing of Resolve x-ray microcalorimeter instrument onboard XRISM [J].
Imamura, Ryuta ;
Tsujimoto, Masahiro ;
Awaki, Hisamitsu ;
Chiao, Meng P. ;
Fujimoto, Ryuichi ;
Ishisaki, Yoshitaka ;
Kelley, Richard L. ;
Kilbourne, Caroline A. ;
Porter, Frederick S. ;
Sawada, Makoto ;
Sneiderman, Gary A. ;
Takei, Yoh ;
Yamada, Shinya .
X-RAY, OPTICAL, AND INFRARED DETECTORS FOR ASTRONOMY X, 2022, 12191
[5]   Status of Resolve instrument onboard X-Ray Imaging and Spectroscopy Mission (XRISM) [J].
Ishisaki, Yoshitaka ;
Kelley, Richard L. ;
Awaki, Hisamitsu ;
Balleza, Jesus C. ;
Barnstable, Kim R. ;
Bialas, Thomas G. ;
Boissay-Malaquin, Rozenn ;
Brown, Gregory, V ;
Canavan, Edgar R. ;
Cumbee, Renata S. ;
Carnahan, Timothy M. ;
Chiao, Meng P. ;
Comber, Brian J. ;
Costantini, Elisa ;
Den Herder, Jan-Willem A. ;
Dercksen, Johannes ;
de Vries, Cor P. ;
DiPirro, Michael J. ;
Eckart, Megan E. ;
Ezoe, Yuichiro ;
Ferrigno, Carlo ;
Fujimoto, Ryuichi ;
Gorter, Nathalie ;
Graham, Steven M. ;
Grim, Martin ;
Hartz, Leslie S. ;
Hayakawa, Ryota ;
Hayashi, Takayuki ;
Hell, Natalie ;
Hoshino, Akio ;
Ichinohe, Yuto ;
Ishida, Manabu ;
Ishikawa, Kumi ;
James, Bryan L. ;
Kenyon, Steven J. ;
Kilbourne, Caroline A. ;
Kimball, Mark O. ;
Kitamoto, Shunji ;
Leutenegger, Maurice A. ;
Maeda, Yoshitomo ;
McCammon, Dan ;
Miko, Joseph J. ;
Mizumoto, Misaki ;
Okajima, Takashi ;
Okamoto, Atsushi ;
Paltani, Stephane ;
Porter, Frederick S. ;
Sato, Kosuke ;
Sato, Toshiki ;
Sawada, Makoto .
SPACE TELESCOPES AND INSTRUMENTATION 2022: ULTRAVIOLET TO GAMMA RAY, 2022, 12181
[6]  
Izawa K., 2008, HIGH SPEED ROTATION
[7]   Cryogen free cooling of ASTRO-H SXS Helium Dewar from 300 K to 4 K [J].
Kanao, Ken'ichi ;
Yoshida, Seiji ;
Miyaoka, Mikio ;
Tsunematsu, Shoji ;
Otsuka, Kiyomi ;
Hoshika, Shunji ;
Narasaki, Katsuhiro ;
Mitsuda, Kazuhisa ;
Yamasaki, Noriko ;
Takei, Yoh ;
Fujimoto, Ryuji ;
Sato, Yoichi ;
Okarnoto, Atsushi ;
Noda, Hirofumi ;
DiPirro, Michel J. ;
Shirron, Peter J. .
CRYOGENICS, 2017, 88 :143-146
[8]  
Kelley R. L, 2016, SPIE C SER, V9905, DOI [10.1117/12.2232509, DOI 10.1117/12.2232509]
[9]  
Kurihara M., 2022, P SPIE, V12181, p121815W, DOI [10.1117/12.2627632, DOI 10.1117/12.2627632]
[10]   Planck pre-launch status: The HFI instrument, from specification to actual performance [J].
Lamarre, J. -M. ;
Puget, J. -L. ;
Ade, P. A. R. ;
Bouchet, F. ;
Guyot, G. ;
Lange, A. E. ;
Pajot, F. ;
Arondel, A. ;
Benabed, K. ;
Beney, J. -L. ;
Benoit, A. ;
Bernard, J. -Ph. ;
Bhatia, R. ;
Blanc, Y. ;
Bock, J. J. ;
Breelle, E. ;
Bradshaw, T. W. ;
Camus, P. ;
Catalano, A. ;
Charra, J. ;
Charra, M. ;
Church, S. E. ;
Couchot, F. ;
Coulais, A. ;
Crill, B. P. ;
Crook, M. R. ;
Dassas, K. ;
de Bernardis, P. ;
Delabrouille, J. ;
de Marcillac, P. ;
Delouis, J. -M. ;
Desert, F. -X. ;
Dumesnil, C. ;
Dupac, X. ;
Efstathiou, G. ;
Eng, P. ;
Evesque, C. ;
Fourmond, J. -J. ;
Ganga, K. ;
Giard, M. ;
Gispert, R. ;
Guglielmi, L. ;
Haissinski, J. ;
Henrot-Versille, S. ;
Hivon, E. ;
Holmes, W. A. ;
Jones, W. C. ;
Koch, T. C. ;
Lagardere, H. ;
Lami, P. .
ASTRONOMY & ASTROPHYSICS, 2010, 520