Automated 'oscillometric' blood pressure measuring devices: how they work and what they measure

被引:21
|
作者
Sharman, James E. [1 ]
Tan, Isabella [2 ,3 ]
Stergiou, George S. [4 ]
Lombardi, Carolina [5 ,6 ,7 ]
Saladini, Francesca [8 ]
Butlin, Mark [2 ]
Padwal, Raj [9 ]
Asayama, Kei [10 ,11 ]
Avolio, Alberto [2 ]
Brady, Tammy M. [12 ]
Murray, Alan [13 ]
Parati, Gianfranco
机构
[1] Univ Tasmania, Menzies Inst Med Res, Hobart, Tas, Australia
[2] Macquarie Univ, Macquarie Med Sch, Fac Med Hlth & Human Sci, Sydney, NSW, Australia
[3] George Inst Global Hlth, Sydney, NSW, Australia
[4] Natl & Kapodistrian Univ Athens, Sch Med, Sotiria Hosp, Dept Med 3,Hypertens Ctr STRIDE 7, Athens, Greece
[5] San Luca Hosp, Ist Auxol Italiano, IRCCS Sleep Disorders Ctr, Milan, Italy
[6] San Luca Hosp, Dept Cardiovasc Neural & Metab Sci, Milan, Italy
[7] Univ Milano Bicocca, Dept Med & Surg, Milan, Italy
[8] Cittadella Town Hopsital, Cardiol Unit, Padua, Italy
[9] Univ Alberta, Dept Med, Edmonton, AB, Canada
[10] Teikyo Sch Med, Dept Hyg & Publ Hlth, Tokyo, Japan
[11] Univ Leuven, Dept Cardiovascu Sci, Res Unit Hypertens & Cardiovasc Epidemiol, Studies Coordinating Ctr,KU Leuven, Leuven, Belgium
[12] Johns Hopkins Univ, Div Pediat Nephrol, Sch Med, Baltimore, MD USA
[13] Newcastle Univ, Sch Engn & Cardiovasc Phys, Fac Med Sci, Newcastle Upon Tyne, Tyne & Wear, England
关键词
MEDICAL INSTRUMENTATION/EUROPEAN SOCIETY; HYPERTENSION/INTERNATIONAL ORGANIZATION; ARTERIAL STIFFNESS; UNIVERSAL STANDARD; CUFF PRESSURE; VALIDATION; ASSOCIATION; SPHYGMOMANOMETERS; RECOMMENDATIONS; HYPERTENSION;
D O I
10.1038/s41371-022-00693-x
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Automated 'oscillometric' blood pressure (BP) measuring devices (BPMDs) were developed in the 1970s to replace manual auscultatory BP measurement by mercury sphygmomanometer. Automated BPMDs that have passed accuracy testing versus a reference auscultatory sphygmomanometer using a scientifically accepted validation protocol are recommended for clinical use globally. Currently, there are many thousands of unique automated BPMDs manufactured by hundreds of companies, with each device using proprietary algorithms to estimate BP and using a method of operation that is largely unchanged since inception. Validated automated BPMDs provide similar BP values to those recorded using manual auscultation albeit with potential sources of error mostly associated with using empirical algorithms to derive BP from waveform pulsations. Much of the work to derive contemporary BP thresholds and treatment targets used to manage cardiovascular disease risk was obtained using automated BPMDs. While there is room for future refinement to improve accuracy for better individual risk stratification, validated BPMDs remain the recommended standard for office and out-of-office BP measurement to be used in hypertension diagnosis and management worldwide.
引用
收藏
页码:93 / 100
页数:8
相关论文
共 50 条
  • [1] Automated ‘oscillometric’ blood pressure measuring devices: how they work and what they measure
    James E. Sharman
    Isabella Tan
    George S. Stergiou
    Carolina Lombardi
    Francesca Saladini
    Mark Butlin
    Raj Padwal
    Kei Asayama
    Alberto Avolio
    Tammy M. Brady
    Alan Murray
    Gianfranco Parati
    Journal of Human Hypertension, 2023, 37 : 93 - 100
  • [2] Oscillometric wrist blood pressure measuring devices
    Braam, RL
    Aslan, B
    Thien, T
    NETHERLANDS JOURNAL OF MEDICINE, 2003, 61 (10): : 313 - 317
  • [3] BLOOD-PRESSURE MONITORING - AUTOMATED OSCILLOMETRIC DEVICES
    RAMSEY, M
    JOURNAL OF CLINICAL MONITORING, 1991, 7 (01): : 56 - 67
  • [4] Automated blood pressure measuring devices: how are they clinically validated for accuracy?
    Jennifer S. Ringrose
    Raj Padwal
    Journal of Human Hypertension, 2023, 37 : 101 - 107
  • [5] Automated blood pressure measuring devices: how are they clinically validated for accuracy?
    Ringrose, Jennifer S.
    Padwal, Raj
    JOURNAL OF HUMAN HYPERTENSION, 2023, 37 (02) : 101 - 107
  • [6] Multi-channel architecture for evaluation of automated oscillometric blood pressure devices
    Postolache, Octavian
    Girao, Pedro Silva
    Postolache, Gabriela
    2013 IEEE INTERNATIONAL SYMPOSIUM ON MEDICAL MEASUREMENTS AND APPLICATIONS PROCEEDINGS (MEMEA), 2013, : 207 - 212
  • [7] Automated Oscillometric Blood Pressure Measurement in Children
    Chiolero, Arnaud
    Bovet, Pascal
    Stergiou, George S.
    JOURNAL OF CLINICAL HYPERTENSION, 2014, 16 (06): : 468 - 468
  • [8] Measuring blood pressure in pregnancy and postpartum: assessing the reliability of automated measuring devices
    Lan, Patrick G.
    Clayton, Philip A.
    Hyett, Jon
    Gillin, Adrian G.
    HYPERTENSION IN PREGNANCY, 2014, 33 (02) : 168 - 176
  • [9] Comparison of high definition oscillometric and Doppler ultrasonic devices for measuring blood pressure in anaesthetised cats
    Petric, Aleksandra Domanjko
    Petra, Zrimsek
    Jerneja, Sredensek
    Alenka, Seliskar
    JOURNAL OF FELINE MEDICINE AND SURGERY, 2010, 12 (10) : 731 - 737
  • [10] BIOMECHANICAL BASIS OF OSCILLOMETRIC BLOOD PRESSURE MEASURING TECHNIQUE
    Lan, H.
    Al-Jumaily, A. M.
    Hing, W.
    Lowe, A.
    IMECE2009: PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION, VOL 2, 2010, : 481 - 483