Reconstruction of neutron spectrum emitted by portable 14 MeV neutron generator by a combination of different methods

被引:0
作者
Mikszuta-Michalik, Katarzyna [1 ]
Miklaszewski, Ryszard [1 ]
机构
[1] Inst Plasma Phys & Laser Microfus, 23 Hery St, PL-01497 Warsaw, Poland
关键词
Neutron spectrum; Nuclear fusion; Activation method; Inverse problems; Unfolding; Neutron generator; CALIBRATION;
D O I
10.1016/j.fusengdes.2023.114129
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
The presented paper is a continuation of the Tikhonov Regularisation, Minimum Fisher Information, Maximum Entropy, and Maximum Likelihood methods application to unfolding the neutron spectra emitted by the fusion devices from activation measurement. The aim of the analysis is the evaluation of the possible uncertainty improvement. The developed algorithms and methodology were validated with 14 MeV portable neutron generators before application to the analysis of the neutron spectrum emitted from tokamak. The analysis concerns plasma-target generator did not provide satisfactory uncertainty of the results. The modification of the irradiation foils' set and the improvement in the activity measurement precision progress the results. The sealed tube portable neutron generator irradiated the Al, Fe, Ni, Zr, Au, Mg, and Nb foils. The HPGe spectrometer measured the induced activity with an uncertainty of about 10 %. The synthetic data analysis was made to establish the ratio between the error of the spectrum reconstruction and the discrepancy between the input data and activities reconstructed for this spectrum by the FISPACT-II inventory code. Two bin structures were considered. One was compatible with the FISPACT-II code, but the energy resolution was not regular. The second was characterised by constant bin spacing connected with the modification requirement before simulation and additional uncertainty of about 5 %. The best results were obtained by calculation of the mean value from all methods. The corresponding reconstruction uncertainty is equal to 11 %. The reconstructed spectrum has a dominant deuterium tritium peak slightly shifted to the higher energies due to the beam-target reaction kinematics. The evaluation of the impact of the deuterium-deuterium reaction due to the long-term operation was not reachable due to the measured high intensity from scattered neutrons.
引用
收藏
页数:11
相关论文
共 23 条
  • [1] [Anonymous], 2014, About Us
  • [2] Aster RC, 2019, PARAMETER ESTIMATION AND INVERSE PROBLEMS, 3RD EDITION
  • [3] 14 MeV calibration of JET neutron detectors-phase 2: in-vessel calibration
    Batistoni, P.
    Popovichev, S.
    Ghani, Z.
    Cufar, A.
    Giacomelli, L.
    Hawkins, P.
    Keogh, K.
    Jednorog, S.
    Laszynska, E.
    Loreti, S.
    Peacock, A.
    Pillon, M.
    Price, R.
    Reed, A.
    Rigamonti, D.
    Stephens, J.
    Bielecki, J.
    Conroy, S.
    Dankowski, J.
    Krasilnikov, V.
    Abduallev, S.
    Abhangi, M.
    Abreu, P.
    Afzal, M.
    Aggarwal, K. M.
    Ahlgren, T.
    Ahn, J. H.
    Aho-Mantila, L.
    Aiba, N.
    Airila, M.
    Albanese, R.
    Aldred, V.
    Alegre, D.
    Alessi, E.
    Aleynikov, P.
    Alfier, A.
    Alkseev, A.
    Allinson, M.
    Alper, B.
    Alves, E.
    Ambrosino, G.
    Ambrosino, R.
    Amicucci, L.
    Amosov, V.
    Sunden, E. Andersson
    Angelone, M.
    Anghel, M.
    Angioni, C.
    Appel, L.
    Appelbee, C.
    [J]. NUCLEAR FUSION, 2018, 58 (10)
  • [4] Validation of the accuracy of the LabSOCS software for mathematical efficiency calibration of Ge detectors for typical laboratory samples
    Bronson, FL
    [J]. JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2003, 255 (01) : 137 - 141
  • [5] Calculations to support JET neutron yield calibration: Modelling of neutron emission from a compact DT neutron generator
    Cufar, Aljaz
    Batistoni, Paola
    Conroy, Sean
    Ghani, Zamir
    Lengar, Igor
    Milocco, Alberto
    Packer, Lee
    Pillon, Mario
    Popovichev, Sergey
    Snoj, Luka
    Abduallev, S.
    Abhangi, M.
    Abreu, P.
    Afzal, M.
    Aggarwal, K. M.
    Ahlgren, T.
    Ahn, J. H.
    Aho-Mantila, L.
    Aiba, N.
    Airila, M.
    Albanese, R.
    Aldred, V.
    Alegre, D.
    Alessi, E.
    Aleynikov, P.
    Alfier, A.
    Alkseev, A.
    Allinson, M.
    Alper, B.
    Alves, E.
    Ambrosino, G.
    Ambrosino, R.
    Amicucci, L.
    Amosov, V.
    Sunden, E. Andersson
    Angelone, M.
    Anghel, M.
    Angioni, C.
    Appel, L.
    Appelbee, C.
    Arena, P.
    Ariola, M.
    Arnichand, H.
    Arshad, S.
    Ash, A.
    Ashikawa, N.
    Aslanyan, V.
    Asunta, O.
    Auriemma, F.
    Austin, Y.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2017, 847 : 199 - 204
  • [6] The characterization of D-T neutron generators in precise neutron experiments
    Czakoj, Tomas
    Kostal, Michal
    Zmeskal, Marek
    Novak, Evzen
    Mravec, Filip
    Cvachovec, Frantisek
    Simon, Jan
    Schulc, Martin
    Uhlar, Radim
    Alexa, Petr
    Matej, Zdenek
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2022, 1034
  • [7] Eads S, 2008, Genie 16C/D 'user manual'
  • [8] Neutron activation analysis: A primary method of measurement
    Greenberg, Robert R.
    Bode, Peter
    De Nadai Fernandes, Elisabete A.
    [J]. SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2011, 66 (3-4) : 193 - 207
  • [9] NEUTRON MEASUREMENT TECHNIQUES FOR TOKAMAK PLASMAS
    JARVIS, ON
    [J]. PLASMA PHYSICS AND CONTROLLED FUSION, 1994, 36 (02) : 209 - 244
  • [10] Knoll G.F., 2000, Radiation Detection and Measurement, Vthird